Safety Precautions

Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide.

  •  The device must not be modified in any way.
  •  Do not place the device close to objects with naked flames.
  •  Do not place the device where the temperature is below/above the operating range.
  •  Do not power on the device or connect it to another electrical device when installing.
  •  Check lightning and water protection when used outdoors.
  •  Do not connect or power the equipment using cables that have been damaged.

Related Documents
This Start Guide only explains the installation of Milesight UR32L router. For more functionality and advanced settings, please refer to the relevant documents as below.

Document Description
UR32L Datasheet Datasheet for UR32L industrial cellular router.
UR32L User Guide Users could refer to the guide for instruction on how to log

in the web GUI, and how to configure all the settings.

The related documents are available on the Milesight website: https://www .milesight-iot.com

Declaration of Conformity

UR32L is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.

All rights reserved: All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means without written authorization from Xiamen Milesight IoT Co., Ltd.

Packing List

Before you begin to install the UR32L router, please check the package contents to verify that you have received the items below.

Milesight UR32L Industrial Router Lite Series fig 1

If any of the above items is missing or damaged, please contact your sales representative.

Hardware Introduction

Overview
  1. Cellular Antenna Connector
  2.  LED Indicator Area
  3. POWER: Power Indicator
  4. SYSTEM: Status Indicator
  5. SIM : Status Indicator
  6. Ethernet LAN1/WAN Port
  7. Ethernet LAN2 Port
  8. Power Connector
  9. SIM and Reset Button Holder
Dimensions (mm)

Milesight UR32L Industrial Router Lite Series fig 3

LED Indicators
LED Indication Status Description
POWER Power Status Off The power is switched off
On The power is switched on

SYSTEM

|

System Status

| Green Light| Static: Start-up
Blinking slowly: the system is running properly
Red Light| The system goes wrong

SIM

|

SIM Card Status

| Off| SIM is registering or fails to register (or there are no SIM

cards inserted)

Green Light

| Blinking slowly: SIM has been registered and is ready for

dial-up

Blinking rapidly: SIM has been registered and is dialing

up now

Static:     SIM    has     been    registered     and    dialed     up

successfully

Signal Strength

|

Signal 1/2/3

| Off| No signal

Green Light

| Static/Off/Off: weak signals with 1-10 ASU (please  check if the antenna is installed correctly, or move the

antenna to a suitable location to get better signal)

Static/Static/Off:       normal    signals      with    11-20    ASU

(average signal strength)

Static/Static/Static: strong signals  with  21-31 ASU

(signal is good)

Reset Button

Reset button is under the SIM slots.

Function Description
SYSTEM LED Action

Reset

| Blinking| Press and hold the reset button for more than 5 seconds.
Static Green →

Rapidly Blinking

| Release the button and wait.
Off → Blinking| The router is now reset to factory defaults.

Ethernet Port Indicator
Indicator Status Description

Link Indicator (Orange)

| On| Connected
Blinking| Transmitting data
Off| Disconnected

Hardware Installation

Environmental Requirements

  •  Power Input: 9-48 VDC (48 VDC is needed for PoE output)
  •  Power Consumption: Typical 1.8 W (Max 2.2 W)
  •  Operating Temperature: -40°C to 70°C (-40°F -158°F)
  •  Relative Humidity: 0% to 95% (non-condensing) at 25°C/77°F
SIM Card Installation

A. Unscrew the cover of the SIM card then take it off.Milesight UR32L
Industrial Router Lite Series fig 4
B. Put SIM card into the slot and screw it up.

Antenna Installation

Rotate the antenna into the antenna connector accordingly.
The external antenna should be installed vertically always on a site with a good signal.

Router Installation

The router can be placed on a desktop or mounted to a wall or a DIN rail.

Wall Mounting (Measured in mm)

Use 4 pcs of M3 × 6 flat head Phillips screws to fix the router on the wall.
Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.

DIN Rail Mounting (Measured in mm)
Use 2 pcs of M3 × 6 flat head Phillips screws to fix the mount clip to the router, and then hang the device to the DIN rail. The width of DIN rail is 3.5cm.

Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.Milesight UR32L Industrial Router Lite Series fig
7

Log in the Web GUI of Router

Please connect PC to LAN port of UR32L router. PC can obtain an IP address, or you can configure a static IP address manually. The following steps are based on Windows 10 operating system for your reference.
IP Address: 192.168.1.1
Username: admin
Password: password
A. Go to “Control Panel” → “Network and Internet” → “Network and Sharing Center”, then click “Ethernet”
(May have different names).

Milesight UR32L Industrial Router Lite Series fig 8

B. Go to “Properties” → “Internet Protocol Version 4(TCP/IPv4) ”, select “Obtain an IP address automatically” or “Use the following IP address”, then assign a static IP manually within the same subnet of the device.

C. Open a Web browser on your PC (Chrome is recommended), type in the IP address 192.168.1.1, and press Enter on your keyboard.
D. Enter the username, password, and click “Login”. If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes.

E. When you login with the default username and password, you will be asked to modify the password. It’s suggested that you change the password for the sake of security. Click “Cancel” button if you want to modify it later.Milesight UR32L Industrial Router Lite Series fig
11

F. After you login the Web GUI, you can view system information and perform configuration on the router.

Milesight UR32L Industrial Router Lite Series fig 12

Network Configuration

This chapter explains how to connect UR32L to network via WAN connection or cellular.

Ethernet WAN Configuration

A. Go to “Network > Interface > Port” to change LAN1 to WAN port.Milesight
UR32L Industrial Router Lite Series fig 13

B. Go to “Network > Interface > WAN” to select connection type and configure WAN parameters, click “Save & Apply” button to make the changes take effect.

Milesight UR32L Industrial Router Lite Series fig 14

C. Connect WAN port to another network devices like modem.
D. Go to “Network > Interface > Link Failover” to rise the WAN priority to 1.
E. Open your preferred browser on PC, then type any available web address into address bar and see if it is able to visit Internet via UR32L router.

Milesight UR32L Industrial Router Lite Series fig 15

Cellular Connection Configuration

A. Go to “Network > Interface > Cellular > Cellular Setting” to configure APN, PIN code or other cellular info, click “Save” and “Apply” to save the configuration.Milesight UR32L Industrial Router Lite Series fig
16

B. Go to “Network > Interface > Link Failover” to enable SIM and rise link priority.

Milesight UR32L Industrial Router Lite Series fig 17

C. Click “Edit” to configure ICMP ping detection information.

Milesight UR32L Industrial Router Lite Series fig 18

D. Click “Status > Cellular” to view the status of the cellular connection. If it shows “Connected”, it means SIM has dialed up successfully. On the other hand, you can check the status of SIM indicator. If it keeps on green light statically, it means SIM has dialed up successfully.

E. Open your preferred browser on PC, then type any available web address into address bar and see if it is able to visit Internet via UR32L router.

Milesight UR32L Industrial Router Lite Series fig 19

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals