INNOSILICON A5+ DashMaster Profitability ASIC Miner User Manual
- June 6, 2024
- INNOSILICON
Table of Contents
INNOSILICON A5+ DashMaster Profitability ASIC Miner
OVERVIEW
-
Part Number
A5+ DashMaster ASIC -
Hash Rate
65Gh/s (+-8%) -
Power
1500 +/-8% -
Size (L×W×H)
265mm(L) x 250mm(W) x 155mm(H) -
Net Weight
6.02KG (without PSU) -
Operating Temperature
0-40 ℃ -
Network Connection
Ethernet
CABLE CONNECTION
CHECK THE MINER BEFORE POWER ON
- Check the warranty sticker is well or not, especially the hashboards PSU port side. If the warranty sticker is damaged when you received the miner, please contact our After-sales.
- Before you power on the miner, shake the miner softly, if you can hear the sound of metal banging on metal, please contact our After-sales.
- Check if the fan work well, if you find the fans broken please contact our After-sales.
- Check the cable connection, if it is different from below picture, please connect the cables as below.
CONNECT THE PSU
Every hashboard needs to be inserted with 2 PSU cables according to the following image, Controller only needs 1 PSU cable.
CONNECT THE ETHERNET CABLE
Insert one end of the Ethernet cable into the router and the other end into
the slot shown in the following image, you should plug in the miner one by
one, only when you have accomplished IP Setting of the previous one you can
plug in another miner. IP SET button: Press it more
than 5 seconds to recover the IP to 192.168.1.254.
RESET button: Your miner will restart if you press it. It wont recover your
settings to the default.
ENTER THE MINER CONSOLE
By default, the miner uses Static IP to access the control webpage of the
miner.
Input 192.168.1.254 into the browser, then click ‘Enter’ to enter the miner’s
control webpage (Chrome is the suggested browser).
Cant access the miner console?
Maybe it is because miner IP and the router IP have a different network
segment, two ways to solve it:
-
Modify the router IP to 192.168.1.1,then try again.
-
Don’t want to change the network segment of the router? Do it as below:
Connect the miner and computer with a network cable. Open the windows system control panel, go to Network and Internet — Network and share center – change the adapter settings, the mouse cursor to the “Local Area Connection” click the right mouse button to view properties. In the properties panel, double click the “Internet protocol version 4(TCP/IP)” . Then select the “Use the following IP address”, fill in the IP address and Subnet mask as the right image. -
Press the OK button twice to confirm the changes.Then modify the IP address of the miner (Do it as the follow 4.4) to guarantee the miner and the router have the same network segment.Then connect the miner with the router,connect the PC with the router and select the “Obtain the IP address automatically”.Now you can enter the IP through the browser into the control interface
CONFIG THE MINER
Enter ‘Miner Configuration’ page, select ‘General Settings’. Click the lower right corner enter log-in page.
Enter the default password“12345678”, then click lower right corner LOGIN to enter configuration page. Password is wrong/error?—Please contact our after-sales people.
Enter the mining pool’s URL, Worker, password according to the following
image, then click SUBMIT
.The miner will start mining, and the page will return to the ‘Miner
Configuration’ page. It will show the user’s modified setting.
Note: As the factory reset will not reset the password to “12345678”, you
need to remember what you have modified your password to. Should you forget
the password, it can only recovered through our paid support. (Very
IMPORTANT!!!) Note, over clock is at your
own risk and vary in performance from miner to miner. It may damage the miner
in overclock condition
To avoid IP conflict when using 2 or more miners at the same time, the IP
address needs to be changed. Enter the network interface shown in the
following image, and modify the IP address to you need, then click the “Save”
to save it.
Note:If you change the miner IP address to another network segment, after you
save it there will be 3 circles keep spinning,that is ok.
IP address: If the router address is 192.168.0.1,you can change the miner’s IP address to 192.168.0.#(# can be any number between 10-253 but every miner’s
must be unique).
Subnet mask: Keep it consistent with your computer.
Gateway: Same with the router address.
DNS: It is recommended to modify the DNS to the local network operator near the location of the miner. For example, the mining machine uses telecommunication broadband in Beijing, China. Search in Baidu or Google search engine “Beijing Telecom DNS” to get the DNS: 219.141.136.10. Then use this DNS for your miner.
When the above information is input, click the lower right corner SAVE &APPLY to save.
Enter ‘Miner Status’ page to check the status on the mining pool configuration and performance of the miner.
APPENDIX
MODIFY THE LOGIN PASSWORD
Select the “Administration” interface at System, then you can modify your password. Then click SAVE PASSWORD to save your new password. Note: As the factory reset will not reset the password to the default password, you must take care your new password. If you forget the password, it can only recovered through our paid support. (Very IMPORTANT!!!) )
UPGRADE THE FIRMWARE
Build date is the version of the firmware. If your miner build date is before
NOV 24,please upgradeyour miner via a TF card. Here is the instruction:
http://www.innosilicon.com.cn/api/download.php?url=TF-card-firmware-update-
manual-en.pdf
If your miner build date is NOV 24 or later, a web upgrade is OK, you can do
it as below .
Select the “Upgrade” interface at System option, click to choose the firmware
you want to upgrade, click the “update” to start the upgrade. The upgrade is
success when you see the progress bar reach to 100%.Note: Don’t power off the miner when is is upgrading. When the
progress bar reach to 100%, upgrade done and it will reboot by itself. Then
use “Ctrl+F5” to refresh.