Product Information
Specifications
-
Product: Philips TubePoint Gen 2
-
Features: Versatile, high performance, long-lasting tunnel
lighting -
Driver Included: Yes
-
Light Source Replaceable: Yes
-
Dimmable: Yes
-
Housing Color: Dark Gray
-
CE Mark: Yes
-
Flammability Mark: Yes
-
Ingress Protection Code: IP66
-
Surge Protection: 6 kV differential mode and 6 kV common mode
Product Usage Instructions
Installation
- Ensure the area where the TubePoint Gen 2 will be installed is suitable for mounting on normally flammable surfaces.
- Mount the luminaire securely using appropriate fixtures and tools.
- Connect the power supply according to the manufacturer’s instructions.
FAQ
Q: Can I replace the light source myself?
A: Yes, the light source is replaceable. Refer to the product manual for
detailed instructions on how to replace it safely.
Philips TubePoint Gen 2: versatile, high performance and long-lasting tunnel lighting
TubePoint gen2
Many tunnel authorities have outdated tunnel lighting installations that
urgently need replacing, but have only a limited budget to achieve it. Philips
TubePoint Gen2 is the perfect solution. It’s a cost-effective solution that’s
the result of years of experience in tunnel lighting and underpass lighting,
combined with the latest technologies developed by Philips. With its modular
design and state-of-the-art LED architecture, TubePoint Gen2 is a versatile,
cost-effective luminaire that meets the most stringent tunnel lighting
requirements. Manufactured from the highest-quality components that are
specifically designed for tunnels, these tunnel luminaires promise a long
lifetime, great performance and low maintenance costs. The lighting efficiency
and wide choice of optics means the number of luminaires required for an
installation can be reduced significantly compared with conventional
solutions. And a high lumen per watt ratio at system level improves the total
cost of ownership. TubePoint Gen2 is part of the Philips TotalTunnel solution
for complete tunnel lighting. A solution you can trust for versatile, high-
performance lighting in traffic tunnels.
Benefits
- Versatile luminaire range suitable all types of traffic tunnels
- Economical LED solution for point source tunnel lighting schemes
- High performance and efficient
- Quick and easy mounting
TubePoint gen2
Features
- Wide range of optics and lumen packages
- Mounting and connectivity options
- Option of a remote driver
- Compatible with tunnel controls from Philips and third parties
- Service tag: QR-based identification for maintenance, installation and spare part information
Application
- Tunnel
- Underpass
Versions
TubePoint GEN2-BGP236
Dimensional drawing
Product details
TubePoint gen2
General Information | General Information |
---|---|
Driver included | Yes |
Product
Light source replaceable| Yes| | Order Code| Full Product
Name| code| units| family code
Service tag| Yes| | 912300024108| BGP235 LED30-4S/740 DSM11 D9 MIO-CIO|
LED30| 1 unit| BGP235
| | | | MBQ| | |
Light Technical| | | 912300024109| BGP235 LED50-4S/740 DSM11 D9 MIO-
CIO| LED50| 1 unit| BGP235
Luminaire light beam spread| 101° x 158°| | | MBQ| | |
Light source color| 740 neutral white| | 912300024110| BGP235
LED90-4S/740 DSM11 D9 MIO-CIO| LED90| 1 unit| BGP235
Correlated Color Temperature (Nom)| 4000 K| | | MBQ| | |
Optical cover type| Flat glass| | 912300024111| BGP235 LED120-4S/740
DSM11 D9 MIO-CIO| LED120| 1 unit| BGP235
Color rendering index (CRI)| >70| | | MB| | |
Optic type outdoor| Distribution
symmetrical
| | 912300024112| BGP235 LED180-4S/740 DSM11 D9 MIO-CIO
MB
| LED180| 1 unit| BGP235
| medium 11| | 912300024114| BGP236 LED360-4S/740 DSM11 D9 MIO-CIO| LED360|
2 units| BGP236
Standard tilt angle side entry| 0°| | | MB| | |
Standard tilt angle posttop| –|
Upward light output ratio| 0
|
Controls and Dimming|
Dimmable| Yes
|
Mechanical and Housing|
Housing Color| Dark gray
|
Approval and Application|
CE mark| Yes
Flammability mark| For mounting on normally flammable
surfaces
Mech. impact protection code| IK09
Ingress protection code| IP66
Surge Protection (Common/ Differential)| Luminaire surge protection
level until 6 kV differential mode and 6 kV common
mode
|
Application Conditions|
Maximum dim level| 10%
Light Technical
Operating and Electrical
© 2024 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify. All trademarks are owned by Signify Holding or their respective owners.
www.lighting.philips.com
2024, June 5 – data subject to change
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>