VIZULO Blackbird Mushroom LED Street Luminaire Instruction Manual
- June 6, 2024
- VIZULO
Table of Contents
Blackbird Mushroom LED Street Luminaire
Instruction Manual
* Depends on configuration. Check the label or technical specification.
Dimensions
Average Netto Weight
BBM
BG 032
8.3 Kg
|
---|---
Acceptable luminaire mounting angle relative to the ground.| Unacceptable
luminaire mounting angle relative to the ground.
These limitations only apply when mounting the luminaire outdoors!
WARNING!
- Do not touch LED modules!
- Do not put any tools or other items on LED modules!
- In case any LED is physically damaged (example shown below) the warranty is void.
LED | Power | CCT | Risk group | Remarks |
---|---|---|---|---|
Olson Square | 5 … 100 W | ≤ 5700 K | RG1 after TBC m* | Label required |
Luxeon 5050 | 5 … 100 W | ≤ 5700 K | RG1 after TBC m* | Label required |
Duris S8 | 5 … 100 W | ≤ 5700 K | RG1 after TBC m* | Label required |
*The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than shown in the table above is not expected.
Standard configuration
Configuration with terminal block
Watertight cable connector has to be ordered separately
Article | Description |
---|---|
70000313 | 2-pole terminal block with PE |
70000304 | 4-pole terminal block with PE |
70000314 | 2-pole terminal block |
70000315 | 4-pole terminal block |
ATTENTION! In the case of the NEMA/ZHAGA Socket.
IP66 applies only for luminaire body and for connection between luminaire body
and NEMA/ZHAGA Socket, and do not apply to any mounted control
device and connection between the control device and NEMA/ZHAGA Socket.
MCB/Inrush current table
Tridonic LED driver
Standard/High density| In-rush current
(peak/duration)| B1OA| B16A| B20A| 8254| C1OA| C16A| C20A| C25A
BB 8-16 LED, 8-33 W| 36 A (195 us)| 10| 16| 21| 28| 16| 21| 35| 44
BB 16-24 LED, 19-60 W| 32 A (267 ps)| 7| 12| 15| 19| 11| 20| 25| 30
BB 32-40 LED, 28-80 W| 37 A (287 its)| 7| 12| 15| 19| 11| 20| 25| 30
BB 40-64 LED, 44-100 W| 56 A (280 us)| 5| 8| 11| 14| 10| 16| 22| 22
BB 64-84 LED, 88-100 W| 84 A (255µs)| 3| 5| 8| 11| 6| 10| 16| 17
BB 84 LED, 92-100 W| 112 A (2801.6)| 2| 4| 5| 7| 5| 8| 11| 11
BB 96 LED, 100 W| 121 A (287 p.$)| 2| 3| 5| 6| 3| 5| 9| 10
Tridonic LED driver
ECO| In-rush current
(peak/duration)| B10A| B164| B204| B254| C104| C164| C204| C254
BBE 6-10 LED, 12-33 W| 36 A (195 ps)| 10| 16| 21| 28| 16| 21| 35| 44
BBE 6-12 LED, 16-59 W| 32 A (267 ps)| 7| 12| 15| 19| 11| 20| 25| 30
BBE 10-18 LED, 19-80 W| 37 A (287 ps)| 7| 12| 15| 19| 11| 20| 25| 30
BBE 16-34 LED, 37-100 W| 56 A (280 ps)| 5| 8| 11| 14| 10| 16| 22| 22
BBE 20-48 LED, 46-100 W| 84 A (255 Rs)| 3| 5| 8| 11| 6| 10| 16| 17
BBE 48 LED, 46-100 W| 121 A (2801.6) _| 2| 3| 5| 6| 3| 6| 9| 10
Osram LED driver
Standard/High density| In-rush current
(peak/duration)| B10A| B16A| B20A| B25A| C10A| C16A| C20A| C25A
BB 8-16 LED, 8-40 W| 45 A (195 ps)| 10| 17| 21| 28| 16| 27| 33| 44
BB 20-32 LED, 18-66 W| 53 A (267 ps)| 7| 12| 15| 20| 11| 19| 24| 32
BB 32-48 LED, 28-96 W| 57 A (287 ps)| 7| 12| 15| 20| 11| 19| 24| 32
BB 48-84 LED, 52-100 W| 62 A (280 ps)| 4| 8| 10| 14| 6| 12| 16| 22
BB 84 LED, 90-100 W| 114 A (255 ps)| 3| 6| 7| 10| 5| 9| 12| 16
BB 96 LED, 100 W| 119 A (280 Rs)| 2| 4| 6| 8| 3| 7| 9| 12
Osram LED driver
ECO| In-rush current
(peak/duration)| BlOA| B164| B20A| B25A| ClOA| C164| C20A| C25A
BBE 4-8 LED, 11-41 W| 45 A (195 ps)| 10| 17| 21| 28| 16| 27| 33| 44
BBE 6-16 LED, 16-66 W| 53 A (267 its)| 7| 12| 15| 20| 11| 19| 24| 32
BBE 12-24 LED, 28-96 W| 57 A (287 its)| 7| 12| 15| 20| 11| 19| 24| 32
BBE 18-44 LED, 41-100 W| 62 A (280 its)| 4| 8| 10| 14| 6| 12| 16| 22
BBE 48 LED, 100 W| 119 A (255 ps)| 2| 4| 6| 8| 6| 7| 9| 12
Terms of use and maintenance
Before the luminaire is turned on, it should be mounted according to this
mounting instruction or any other applicable regulations.
Mounting instructions
Mounting of luminaire must be performed by a qualified person according to the
following instructions:
- The warranty of the luminaire does not apply if the mounting of the luminaire has been performed in precipitation (rain, snow, hail).
- The warranty of luminaire does not apply if a control system unauthorized by VIZULO or an inapplicable LED driver has been used to drive the luminaire.
- The warranty of luminaire does not apply if it has been used in an unsuitable ambient temperature or has been supplied by voltage outside of the specified range.
- The warranty of the luminaire does not apply if the LED driver program has been changed in any way.
- The warranty of the luminaire does not apply if the logged history data of the LED driver has been deleted without the permission of VIZULO.
- The warranty of luminaire does not apply, if it has been mounted in unspecified angles or upside down (luminaire glass directed up), or it has been completely submerged underwater.
Safety instructions
Any actions with the luminaire must be performed by a qualified person, who is
certified according to with national regulations and requirements.
To prevent any accidents person installing the luminaire must follow national
safety requirements and following instructions:
- The label containing technical parameters of the luminaire has to be studied before the work on it has begun.
- Any luminaire build or design changes are prohibited.
- The luminaire must be used in good technical condition and according to with this instruction.
- Only VIZULO authorized spare parts and accessories can be used to repair the luminaire.
- The repair of the luminaire has to be performed by a qualified and certified person.
Maintenance and repair
Luminaire has to be disconnected from the electrical grid before it is opened
and/or repaired!
The person working with the luminaire must follow national regulations and
legislations that apply to the maintenance and testing of electrical or
electronic appliances.
- The luminaire may need to be cleaned depending on its environment. Only a damp cloth or a sponge may be used to clean the luminaire. Use only household detergents diluted by water.
- Only VIZULO authorized spare parts may be used for the luminaire.
- Instruction for changing spare parts must be requested from VIZULO and studied before the repair is attempted.
- LED modules, lenses, and LED drivers can be changed on an installed luminaire, but it is advised to perform this task indoors to avoid water entering the luminaire.
- Spare parts (lens, LED modules, and drivers) should be ordered from the information available on the luminaire label.
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similarly qualified person.
Caution, risk of electrical shock
In case the mains cable is damaged, the luminaire is no longer usable, and
it must be either recycled or repaired.
The repair can only be performed by VIZIO. Contact either your direct sales
manager or look for contact information on our home page –
www.vizulo.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>