CYBERVIEW RP-120 20-Inch Rack LCD Drawer User Manual

June 6, 2024
CyberView

CYBERVIEW - logo dedicated KVM switch and rackmount screen technology
RP-120 20-Inch Rack LCD Drawer
User Manual
20” LCD 1600 x 1200

Designed and manufactured by Austin Hughes

Legal Information
First English printing, December 2021
Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. The information in this document is subject to change without notice. We are not liable for any injury or loss that results from the use of this equipment.

Safety Instructions
Please read all of these instructions carefully before you use the device. Save this manual for future reference.

  • Unplug equipment before cleaning. Don’t use liquid or spray detergent; use a moist cloth.
  • Keep equipment away from excessive humidity and heat. Preferably, keep it in an air-conditioned environment with temperatures not exceeding 40º Celsius (104º Fahrenheit).
  • When installing, place the equipment on a sturdy, level surface to prevent it from accidentally falling and causing damage to other equipment or injury to persons nearby.
  • When the equipment is in an open position, do not cover, block or in any way obstruct the gap between it and the power supply. Proper air convection is necessary to keep it from overheating.
  • Arrange the equipment’s power cord in such a way that others won’t trip or fall over it.
  • If you are using a power cord that didn’t ship with the equipment, ensure that it is rated for the voltage and current labeled on the equipment’s electrical rating label. The voltage rating on the cord should be higher than the one listed on the equipment’s ratings label.
  • Observe all precautions and warnings attached to the equipment.
  • If you don’t intend on using the equipment for a long time, disconnect it from the power outlet to prevent being damaged by transient over-voltage.
  • Keep all liquids away from the equipment to minimize the risk of accidental spillage. Liquid spilled onto the power supply or on other hardware may cause damage, fi re, or electrical shock.
  • Only qualifi ed service personnel should open the chassis. Opening it yourself could damage the equipment and invalidate its warranty.
  • If any part of the equipment becomes damaged or stops functioning, have it checked by qualifi ed service personnel.

What the warranty does not cover

  • Any product, on which the serial number has been defaced, modifi ed or removed.
  • Damage, deterioration, or malfunction resulting from:
  • Accident, misuse, neglect, fi re, water, lightning, or other acts of nature, unauthorized product modifi cation, or failure to follow instructions supplied with the product.
  • Repair or attempted repair by anyone not authorized by us.
  • Any damage to the product due to shipment.
  • Removal or installation of the product.
  • Causes external to the product, such as electric power flactuation or failure.
  • Use of supplies or parts not meeting our specifi cations.
  • Normal wear and tear.
  • Any other causes which do not relate to a product defect.
    • Removal, installation, and set-up service charges.

Regulatory Notices Federal Communications Commission (FCC)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Any changes or modifi cations made to this equipment may void the user’s authority to operate this equipment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or  television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Re-position or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Before Installation

  • It is very important to mount the equipment in a suitable cabinet or on a stable surface.
  • Make sure the place has good ventilation, is out of direct sunlight, away from sources of excessive dust, dirt, heat, water, moisture, and vibration.

Unpacking

The equipment comes with the standard parts shown in the package content. Check and make sure they are included and in good condition. If anything is missing or damaged, contact the supplier immediately.

How To Clean Your LCD Monitor

Caution :

  • To avoid the risk of electric shock, make sure your hands are dry before unplugging your monitor from or plugging your monitor into an electrical outlet.
  • When you clean your monitor, do not press down on the LCD screen. Pressing down on the screen can scratch or damage your display. Pressure damage is not covered under warranty.
  • Use only cleansers made specifi call for cleaning monitors and monitor screens. Cleansers not made to clean monitors and monitor screens can scratch the LCD display or strip off the finish.
  • Do not spray any kind of liquid directly onto the screen or case of your monitor. Spraying liquids directly onto the screen or case can cause damage that is not covered under warranty.
  • Do not use paper towels or abrasive pads to clean your monitor. Using an abrasive pad or any wood-based paper product such as paper towels can scratch your LCD screen.

Cleaning Your Monitor

To clean your LCD safely, please follow these steps :

  1. Disconnect the power cord.
  2. Gently wipe the surface using a clean, dry microfi ber cloth. Use as little pressure as possible.

Cleaning Tough Marks and Smudges

To remove tough marks and smudges, please follow these steps :

  1. Disconnect the power cord.

  2. Spray a small amount of non-abrasive cleanser on a microfi ber cloth.
    Caution: Do not spray or apply any liquids directly onto the monitor. Always apply the solution to your microfi ber cloth fi rst, not directly on the parts you are cleaning.

  3. Gently wipe the surface. Use as little pressure as possible.

  4. Wait until your monitor is completely dry before plugging it in and powering it up

Package Content

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Package
Content

RP-120 unit X 1

  • 6ft VGA cable X 1
  • Power cord X 1
  • M6 screw, cage nut & cup washer X 8

The above package content is only for the pure model ( VGA and DVI-D only ).
It varies with options such as HDMI, AV, audio & DC power.

Structure Diagram

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Structure
Diagram

1. LCD panel
2. Installation Slide
3. LCD membrane CYBERVIEW RP 120 20 Inch Rack LCD Drawer - icon
2| 4. Audio speaker
5. Carry handle to release the 2-pt lock
6. 2-point lock
---|---

Dimension

Front View

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Front View

Rear View

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Rear View

Side View

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Side View

UNIT: mm
1mm = 0.03937 inch

Top View

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Top View

Model| Product Dimension
(W x D x H)| Packing Dimension
(W x D x H)| Net Weight| Gross
Weight
---|---|---|---|---
RP-120| 439.6 x 650 x 44 mm
17.3 x 25.6 x 1.73 inch| 595 x 860 x 140 mm
23.4 x 33.9 x 5.5 inch| 13.5 kg
29.7 lb| 17.5 kg
38.5 lb

The weight is only for pure models. It varies with accessories & options such as HDMI, AV, audio & DC power.

Installation – How to install 1U 20″ LCD Tray

CYBERVIEW RP 120 20 Inch Rack LCD Drawer -
Installation

Step 1

  • Attach the left and right mounting bracket to ack 19″ mounting rails.
  • Adjust the mounting bracket to fi t your rack.
  • M6 screw x 8 pcs included.

Leave all M6 screws slightly loose, until you complete the installation in step 3

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Installation
2

Step 2

  • Pick up the LCD tray.
  • Insert the LCD tray into the mounting bracket.
  • Pull and hold the left & right black arrow buttons on the rails.
  • Return the LCD tray to park position.

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Installation
3

Step 3

  •  Fix the rear kit to the mounting bracket with M3.2 screw x 4 pcs included.
    This step is necessary. Failure to complete this will cause damage.

This step is necessary. Failure to complete this will cause damage.

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Installation
4

Step 4
Complete the installation

  • Tighten all 8 pcs of M6 screw to complete the installation.

Product Specifi cations

  LCD
Panel| Manufacturer|
---|---|---
Panel Size ( diagonal )| 20-inch TFT color LCD
Display pixel ( dots x lines )| 1600 x 1200
Brightness ( Typ. )| 300
Contrast Ratio ( Typ. )| 800:1
Color| 16.7 M
Viewing Angle ( L/R/U/D )| 89/89/89/89
Response Time ( ms )| 16
Dot pitch ( mm )| 0.255
Display Area ( mm )| 408.00H x 306.00V
Surface treatment| Anti-glare, Hard-coating
Surface hardness| 3H
Backlight Type| CCFL
MTBF ( hrs )| 45,000
video
Connectivity
| Digital| HDMI| HDMI 1.2, CEA-861-D
---|---|---|---
DVI| DVI-D, TMDS single link
Analog| VGA| Analog 0.7Vp-p
Composite ( BNC )| NTSC & PAL
S-Video ( 4-pin )| NTSC & PAL
Plug & Play| DVI / VGA| VESA EDID structure 1.3
Synchronization| VGA| Separate, Composite & SOG
Audio
Connectivity| Audio Input| Connector| 3.5mm stereo jack
---|---|---|---
Impedance / Power level| 30k0 / 750mV
Audio Output| Connector| 3.5mm stereo jack
Resistance / Power level| 30k0 / 2.8V
Speaker| Dual Stereo Speaker| 2W x 2

* When the audio output is connected, speaker output is OFF

Power Power Supply Range Auto-sensing 100 to 240VAC, 50 / 60Hz
Power Consumption Screen ON Max. 45W
Power saving mode Max. 2W
Power button OFF Max. 1W
Regulatory Safety FCC & CE certifi ed
--- --- ---
Environmental RoHS3 & REACH compliant

  Environmental
Conditions| Operating| Temperature| 0 to 55°C degree
---|---|---|---
Humidity| 20-90%, non-condensing
Altitude| 16,000 ft
Storage / Non-operating| Temperature| -20 to 60°C degree
Humidity| 5-90%, non-condensing
Altitude| 40,000 ft
Shock| 10G acceleration (11ms duration)
Vibration| 10-300Hz 0.5G RMS random
Physical
Specification| Product (WxDxH)| 439.6 x 650 x 44 mm 17.3 x 25.6 x 1.73 inch
---|---|---
Packing (WxDxH)| 595 x 860 x 140 mm
23.4 x 33.9 x 5.5 inch
Net Weight| 13.5 kgs / 29.7 lbs
Gross Weight| 17.5 kgs / 38.5 lbs

* All dimensions stated are subject to change if options are selected/integrated to base model part codes

Applicable
Format| DVI-D / VGA Input| PC Signal| 1600 x 1200 x 60Hz
---|---|---|---
1400 x 1050 x 60Hz
1440 x 900 x 60Hz
1360 x 768 x 60Hz
1280 x 1024 x 60 / 75Hz
1280 x 960 x 60Hz
1280 x 768 x 60 / 75Hz
1152 x 864 x 75Hz
1024 x 768 x 60 / 70 / 75Hz
848 x 480 x 60Hz
800 x 600 x 60 / 72 / 75Hz
720 x 400 x 70Hz
640 x 480 x 60 / 72 / 75Hz
640 x 400 x 70Hz
640 x 350 x 70Hz
HDMI Input| PC Signal| Same as VGA
Video Signal| 720p : 50 / 60Hz
480p :60Hz
576p : 50Hz
Audio Signal| 2ch Linear PCM ( 32 / 44.1 / 48 KHz )

On-screen Display Operation ( OSD )

Power light
Green = On
Orange = Power savingCYBERVIEW RP 120 20 Inch Rack LCD Drawer - icon
2

Membrane Switch| Function
| Power on / off  LCD
| Display the OSD menu
CYBERVIEW RP 120 20 Inch Rack LCD Drawer - icon 9| Scrolls through menu options and adjusts the displayed control
(To auto adjustment by pressing the button for 5 seconds)
| Exit the OSD screen
Toggle analog, digital & video connection (DVI-D and video options only)

On-screen Display Operation ( OSD )

OSD Confi guration Page

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - Display
Operation


| Image:
for the brightness, contrast, color temp, red, green, and blue
| Geometry:
for the auto-adjust, H position, V position, phase, and clock
| Video:
for the color, tint, sharpness, noise reduction, DCDi, and TV Setup
| Audio:
for volume, bass, treble, balance, AVL, and mute
| Misc:
for the language, OSD position, graphic mode, ratio, reset, and timer

Options :

  • HDMI ( HDMI 1.2, CEA-861-D )
  • AV ( S-Video + Composite, BNC )
  • Audio ( Built-in Dual Stereo Speakers, 2W x 2 )
    ( 3.5mm audio jacks for audio in & out )

( 1 ) Either HDMI or DVI-D can be selected.
( 2 ) In some circumstances, if the user connects the LCD to the PC via an HDMI port for video and audio signals, the LCD may display incorrectly on a full screen. If so, please adjust the display card setting on display size to fi x the issue.

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - HDMI Options: DC Power

Model 12V 24V 48V 125V
Input rating
Input voltage: 12-Volt 24-Volt 48-Volt 110-Volt
Input range: 9 ~ 18V 18 ~ 36V 36 ~ 75V 66 ~ 160V
Input current
#NAME? 50 mA 50 mA 50 mA 35 mA
#NAME? 4950 mA 2450 mA 1220 mA 749 mA
Output rating
Output voltage: 12-Volt 12-Volt 12-Volt 12-Volt
Output current: 4.16A 4.16A 4.16A 6.25A
Effi  ciency 84% 85% 85% 91%

DC power

CYBERVIEW RP 120 20 Inch Rack LCD Drawer - DC power *** For DC power option :

  1. If the unit with LCD, earthing may be required
  2. DC option excludes AC power adapter and power cord.

The company reserves the right to modify product specifi cations without prior notice and assumes no responsibility
for any error which may appear in this publication.
All brand names, logos, and registered trademarks are properties of their respective owners.
Copyright 2021 Austin Hughes Electronics Ltd. All rights reserved.

UM-CV-751-RP-120-Q421V1

www.austin-hughes.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals