theben 4940300 DM 4 DALI KNX Actuator Instructions

October 27, 2023
theben

theben 4940300 DM 4 DALI KNX Actuator Instructions

WARNING!
Danger of death through electric shock or fire!

  • Installation should only be carried out by professional electrician!
  • Disconnect the mains power supply prior to installation and/or disassembly!
  • Follow the detailed KNX manual on the Internet!

General information

  • The 4-way actuator DM 4 DALI KNX conforms to EN 60669-2-1 if correctly installed
  • DALI-2 certifi ed
  • It provides the interface between the KNX bus system and the DALI lighting system (Digital Addressable Lighting Interface).
  • It has 4 channels for DALI light control; control is via broadcast telegram, i.e. all participants on one channel are switched/dimmed simultaneously.
  • The ETS (Engineering Tool) can be used to select application programmes, assign specifi c parameters and addresses and transfer them to the device

Technical data

Bus voltage KNX: 21–32 V DC,
Power input KNX bus: < 10 mA
Type: TP1-256
Operating voltage: 110–240 V AC, +10%/–15%
Frequency: 50–60 Hz
Standby output: 0.7 W
Max. capacity loss: 2.5 W
DALI voltage: typ. 16 V DC, short-circuit proof,
basic insulation (no SELV)
Imax = 250 mA
Imin = 60 mA
Number of DALI devices: max. 30 per channel
Max. DALI cable length: 300 m per channel
Max. cable cross-section: 0.5 mm² (Ø 0.8) to
6 mm², strand with crimp terminal: 0.5 mm² to
4 mm²
Dimension: 4 TE, 72 x 68 x 90 mm
Operating temperature: –5 °C … +45 °C
Protection rating: IP 20 in accordance with
EN 60529
Protection class: II subject to correct installation
Pollution degree: 2
Rated impulse voltage: 4 kV

The ETS database is available at
www.theben.de.

Designated Use

  • The DALI actuator with 4 outputs controls the connected DALI lamps in brightness, colour and colour temperature (depending on the device types supported by the DALI lamps). It is designed as a Broadcast Single Master and is DALI-2 certified. Due to broadcast communication, no individual addressing of the DALI lamps is required. All DALI lamps connected to a channel respond together to broadcast commands and cannot be controlled via group or individual commands.
  • For use in residential and other buildings (office buildings, public buildings, hotels etc.)
  • Use only in closed, dry areas

Installation

on DIN top hat rails

Installation

Connection

Do not connect an additional DALI power supply in parallel.

  • For the entire DALI installation of a segment, a maximum cable length of 300 m must not be exceeded (Ø 1.5 mm²).
  • The mains voltage is connected according to the connection sequence on the housing; the connection to the KNX system is made with the KNX plug-in terminal.
  • Connect the cable for the DALI bus to terminals DA+/DA–.

Example of a label with QR code

This device supports KNX Secure. For start-up, the Factory-Default-Setup-Key (FDSK) is required (sticker on the device).

Keep the Factory-Default-Setup-Key in a safe place.

 Remove the stickers from the device for maximum safety. If the FDSK is lost, a recovery is not possible. In this case, startup is only possible „insecure“.

LED flashing signals

Lower (-) LED flashes Excess temperature or power failure

Lower (-) LED and
upper (+) flash| Short circuit

Manual operation

Each channel can be operated via 2 channel buttons. When pressing repeatedly, the increments of 0 % – 25 % – 50 % – 75 % –100 % are selectable.

man. button

(must be enabled via ETS)
The outputs can be switched on/off with the channel buttons (if released via ETS).

  • When the man. button is pressed before (LED lights), no bus telegrams are sent
  • When the man. button is pressed again, the LED goes out, and the bus telegrams are sent again

Detailed information is available in the KNX manual at www.theben.de.

Hotline Theben:
+49 7474 692-369

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

theben User Manuals

Related Manuals