theben LUXORliving E1 4800542 Flush Mounted Actuators Instruction Manual
- May 15, 2024
- theben
Table of Contents
theben LUXORliving E1 4800542 Flush Mounted Actuators
Specifications :
- Switching capacity: 16 A (at 240 V AC, cos φ = 1)
- Suitable for SELV: Yes
- Minimum load: 12 V/100 mA
- Mode of operation: Type 1 B
- Pollution degree: 2
- Rated impulse withstand voltage: 4 kV
- Software class: A
- Connection cross-section: 4 mm2
- Dimensions: 44.4 x 48.6 x 32.3 mm
Product Usage Instructions
Proper Use:
This product is suitable for controlling various functions such as
switching, dimming, and raising/lowering blinds in environments like office
buildings, public buildings, and hotels. Ensure that it is not used with
electric heating or cooling systems.
Installation:
- Secure the device with a circuit breaker of type B or C (EN 60898-1) with a maximum rating of 16 A and 6 kA.
- Avoid connecting mains voltage or any other external voltages to the extension inputs.
- During installation, maintain adequate insulation (minimum 5.5 mm) between mains voltage and the bus or extensions.
Connection:
Refer to the manual for proper bus connection, note the polarity, and
ensure correct plug connections for external inputs. Use the programming
button and LED for setting the physical address.
FAQ:
-
Q: What should I do if the device is not functioning properly?
A: Check the installation to ensure proper connection and insulation. Verify that external voltages are not affecting the device’s operation. -
Q: Can this product be used with electric heating systems?
A: No, this product is not suitable for use with electric heating or cooling systems.
LUXORliving E1 4800542 For more information, see product page
LUXORliving
Hotline Theben:
+49 7474 692-369
WARNING
Danger of death through electric shock or fire!
- Installation should only be carried out by professional electrician!
- Disconnect the mains power supply prior to installation and/or disassembly!
- Further functional descriptions in the LUXORliving handbook.
General information
- The flush-mounted heating actuator E1 of the LUXORliving series complies with EN 60730-2-9 when installed as intended.
- It can be installed with conventional push buttons/switches in flush-mounted boxes.
- Direct connection of electric heating or coo-ling systems
- Binary input for floating contacts, such as push buttons, window contacts, temperature sensors (I2)
- The temperature sensors 9070496, 9070459 and the floor sensor 9070321 available as accessories can be connected to I2.
- The LUXORliving series is a range of compact devices for switching, dimming, heating and controlling.
- Start-up using the LUXORplug software and easy operation using the LUXORplay app (for Android and iOS): www.LUXORliving.co.uk
- When used in a KNX system, programming is completed with the ETS.
Technical data
- Bus voltage KNX: 21–32 V DC, Power input KNX bus: 4 mA (typical)
- Type: TP1-256
- Type of contact: μ-contact
- Switching capacity: 16 A (at 240 V AC, cos ϕ = 1)
- Suitable for SELV: yes
- Minimum load: 12 V/100 mA
- Mode of operation: type 1 B
- Operating temperature: – 5 °C … + 45 °C
- Binary inputs:
- Contact voltage: 3.3 V
- Contact current: 0.5 mA
- Max. cable length: 3 m (external inputs)
- Length of connecting wires: 25 cm
- Pollution degree: 2
- Rated impulse withstand voltage: 4 kV
- Software: class A
- Connection cross-section: 4 mm2
- Dimensions: 44,4 x 48,6 x 32,3 mm
Proper use
- The flush-mounted heating actuators control electric heating or cooling systems.
- If potential-free push buttons or switches are connected to the inputs, they can carry out various functions, such as switching, dimming, raising/lowering blinds etc.
- For use in residential and other buildings (office buildings, public buildings, hotels etc.)
- Only for use in closed, dry rooms
Installation
For installation in conventional flush- mounted boxes (according to DIN 49073).
Connection
-
Disconnect power source.
Secure the device with an upstream type B or type C circuit breaker (EN 60898-1) of max. 16 A 6 kA. -
Protect against accidental contact during installation.
- Do not connect mains voltage or other external voltages to the extension inputs!
- During installation, ensure there is adequate insulation between mains voltage and bus or extensions (min. 5.5 mm).
- The bistable relays used in this product can change their state due to strong vibrations, e. g. during transport.
Important: Apply the bus voltage first before supplying the outputs with voltage. Non-observance may result in damage to the connected consumers.
The ETS database is available at www.theben.de.
Theben AG | Hohenbergstraße 32 | 72401 Haigerloch | GERMANY | Telefon +49 7474 692-369 | info@theben.de | www.theben.de
References
- KNX Smart Home System LUXORliving - Privatkunden
- KNX Smart Home System LUXORliving - Privatkunden
- KNX Smart Home System LUXORliving - Privatkunden
- KNX Smart Home System LUXORliving - Privatkunden
- KNX Smart Home System LUXORliving - Privatkunden
- KNX Smart Home System LUXORliving - Privatkunden
- KNX Smart Home System LUXORliving - Klienci prywatni
- Theben AG - KNX, DALI, Zeitschaltuhren, Bewegungsmelder, Smart Home | Theben AG
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>