Theben 4941641 KNX RF Plus Mini Varme Akt. HU1SRF Instruction Manual

May 15, 2024
theben

Theben 4941641 KNX RF Plus Mini Varme Akt. HU1SRF

Product Specifications

  • Operating Voltage: 230 V AC, 50/60 Hz
  • Standby Output: < 0.4 W
  • Type of Contact: -Contact
  • Switch Output: Not floating
  • Switching Capacity: Max. 1 A or 4 actuators 230 V AC (9070441)
  • Mode of Operation: Type 1
  • Pollution Degree: 2
  • Software Class: A
  • Connection Cross-Section: 4 mm2
  • Dimensions: 44.4 x 48.6 x 24.9 mm
  • Radio Frequency: 868.3 MHz (KNX RF1.R)
  • Transmission Power: < 10 mW
  • Range Open Field: Up to 100 m

Product Usage Instructions

Safety Instructions

1. Danger of death through electric shock or fire! Always consult a professional electrician for installation and disassembly.

2. Use the KNX manual for proper installation and operation.

Installation Instructions

1. Ensure correct connection to the power supply (230 V AC, 50/60 Hz).

2. Respect polarity L/N for smooth operation.

3. Follow the provided dimensions (44.4 x 48.6 x 24.9 mm) for installation space.

Operation Guidelines

1. Use the product to control up to 4 actuators or a maximum of 1 A load.

2. Ensure the software settings are in Class A for proper functionality.

3. Keep the product within the radio frequency range for effective communication (up to 100 m in open field).

FAQ

  • Q: What is the standby power consumption of the product?
    • A : The standby output is less than 0.4 W.
  • Q: What is the maximum switching capacity of the product?
    • A : The product can handle a maximum of 1 A or control up to 4 actuators at 230 V AC.
  • Q: What type of contact does the product have?
    • A : The product has a -Contact type of contact.

WARNING

The danger of death through electric shock or fire!

  • Installation should only be carried out by a professional electrician!
  • Disconnect the mains power supply prior to installation and/or disassembly!
  • Please refer to the KNX manual for detailed functional descriptions.

General information

  • The wireless heating actuator HU 1 S RF KNX corresponds to EN 60730-2-9 if correctly installed.
  • It can be installed with conventional push buttons/switches in flush-mounted boxes.
  • Up to 4 thermal actuators (230 V) can be controlled.
  • Binary input for floating contacts, such as push buttons, window contacts, and temperature sensors (I2).
  • Accessories : temperature sensors 9070496, 9070459; floor sensor 9070321; actuator 9070441.
  • The ETS (Engineering Tool) is used to select application programs, to assign specific parameters and addresses, and to transfer them to the device.

Technical data

  • Operating voltage : 230 V AC, 50/60 Hz
  • Standby output : min.: < 0,4 W
  • Type of contact : ε-contact
  • Switch output : not floating
  • Switching capacity : max. 1 A or 4 actuators 230 V AC (9070441)
  • Mode of operation : Type 1
  • Protection class : II subject to correct installation
  • Operating temperature : – 5 °C … + 45 °C

Binary inputs:

  • Contact voltage : 3.3 V
  • Contact current : 0.5 mA
  • Max. cable length : 3 m (external inputs)
  • Length of connecting wires : 25 cm
  • Pollution degree : 2
  • Rated impulse withstand voltage : 4 kV
  • Software : Class A
  • Connection cross-section : 4 mm2
  • Dimensions : 44.4 x 48.6 x 24.9 mm
  • Radiofrequency : 868,3 MHz (KNX RF1.R)
  • Transmission power: < 10 mW
  • Range open field : up to 100 m

Theben AG herewith declares that this type of radio installation complies with Directive 2014/53/EU. The complete text of the EU Declaration of Conformity is available at the following Internet address:

This device supports KNX Secure. For start-up, the Factory-Default-Setup-Key (FDSK) is required (sticker on the device and the secure card).

  • Keep the Factory-Default-Setup-Key in a safe place.
  • Remove the stickers from the device for maximum safety. If the FDSK is lost, a recovery is not possible. In this case, a start-up is only possibly „insecure“.

Proper use

  • The wireless heating actuators control electronic actuators for heaters or cooling ceilings
  • If potential-free push buttons or switches are connected to the inputs, they can carry out various functions, such as switching, dimming, raising/lowering blinds etc.
  • For use in residential and other buildings (office buildings, public buildings, hotels etc.)
  • Only for use in closed, dry rooms

Installation

¾For installation in conventional flush-mounted boxes (according to DIN 49073).

Connection

Risk of electric shock!

  • ¾The inputs carry mains voltage! When connecting the inputs or before any intervention at one of the inputs, interrupt the 230 supply of the device.
  • ¾Protect against accidental contact during installation.
  • ¾Do not remove the insulation from the unused auxiliary inputs.
  • ¾Do not cut off the conductors of the unused auxiliary inputs.
  • Do not connect the mains voltage (230 V) or other external voltages to the extension inputs!
  • During installation, ensure there is adequate insulation between mains voltage (230 V) and bus or extensions (min. 5.5 mm).
  • LThermal actuators often have a so-called construction site function ex-works and do not close the valve completely in the delivered condition. The heating actuator automatically deactivates this function after switching on the supply voltage and/or after
  • programming and switches the output on for 10 minutes.

Hotline Theben: J +49 7474 692-369

Theben AG

Hohenbergstraße 32 72401 Haigerloch

GERMANY