ELRO CBFS36 Blue Line Smoke Alarm with Magnet Instruction Manual
- June 6, 2024
- ELRO
Table of Contents
ELRO CBFS36 Blue Line Smoke Alarm with Magnet
SPECIFICATIONS
5 years, replaceable
Operating temperature
Operating humidity
Optical sensor
Alarm volume
Capacity
Leisure accommodation vehicle
Visit www.elro.eu
Ceiling mounting
Low battery alert
INTENDED USE: FIRE SAFETY
ESSENTIAL CHARACTERISTICS: PASSED
Nominal activation conditions/ Sensitivity, Response delay (response me) and
Performance under fire condition – Operational reliability – Tolerance to
supply voltage – Durability of operational reliability and response delay,
temperature resistance, vibration resistance, humidity resistance, corrosion
resistance, electrical stability
Installation steps
-
Firstly
Follow instructions to ensure proper installation.
Intended use: Fire detection and fire warning for household or similar residential applications. Local regulations shall be consulted. -
Content
-
Activate / Replace
-
Testing
-
Magnetic plates
-
Rooms 6b. Roof
-
Test and Clean
Test not okay, replace detector!
Low battery alert?
Replace battery and test! (see 3 and 4)
EN Operating mode| LED signal (flash)| LED signal (flash)|
Description mode
---|---|---|---
Normal| 1 x per 32 seconds| None| Device is functioning properly
Test| 1 x per second (3 x), pause of 1,5 seconds| 1 x per seconds (3 x), pause
of 1,5 seconds| Device is being tested
Alarm| 1 x per second (3 x), pause of 1,5 seconds| 1 x per seconds (3 x),
pause of 1,5 seconds| Device has detected smoke
Low battery| 1 x per 32 seconds (simultaneously with beep)| 1 x per 32 seconds
(simultaneously with flash)| Battery is running low
Fault warning| 1 x per 32 seconds (alternating with beep)| 1 x per 32 seconds
(alternating with flash)| Device is not functioning properly
Symbols:
Recycling and disposal: The WEEE symbol means that this product and batteries must be disposed separately from other household waste. When it reaches its end of life, take it to a designated waste collection point in your area to guarantee a safe disposal or recycling. Protect the environment, human health and natural resources!
Read the manual before use and store it in a safe place for future use and maintenance.
Download Declaration of Performance (DoP) at www.elro.eu.
Warnings
- Replace smoke alarm device 10 years after initial activation.
- To prevent injury, this apparatus must be securely a ached to the ceiling in accordance with the installation instructions.
- Batteries shall not be exposed to excessive heat such as sunshine and fire.
- Battery life me shortens without monthly test.
- Keep away from air conditioning/ventilation.
- Do not paint or cover device.
- Consult local regulations.
Troubleshooting
False alarm is often caused by dust or steam. In case of doubt: Leave the building and take ac on!
Additional mounting instructions
- Corridor max width 3m: Max 15m between 2 alarms. Max. 7,5m to front side and alarms at edges/crossings of corridors.
- Galleries : Length and width >2m and >16m², additional alarms below gallery.
- Par al roof slopes: Flat ceiling ≤1m wide, consider as roof slope. Flat ceiling >1m wide, consider as flat ceiling.