Technical specifications
Lamp Type | Description | Voltage | Power | Nom. Tc | Lumen |
---|---|---|---|---|---|
PLP050-RGB | RGB color 50 mm | 10-14 VAC | 13 W | All colors and | 650 lm |
PLP100-RGB | RGB color 100 mm | 10-14 VAC | 31 W | Tunable | 1900 lm |
PLP170-RGB | RGB color 170 mm | 10-14 VAC | 66 W | white | 3700 Ern |
PLP050-WH | Sun White 50 mm | 10-14 VAC | 8W | 5000K | 750 lm |
PLP100-WH | Sun White 100 mm | 10-14 VAC | 25 W | 5000K | 2600 lm |
PLP170-WH | Sun White 170 mm | 10-14 VAC | 57 W | 5000K | 5500 Ern |
PLP050-WW | Warm White 50 mm | 10-14 VAC | 8W | 3300K | 700 lm |
PLP100-WW | Warm White 100 mm | 10-14 VAC | 23 W | 3300K | 2400 lm |
PLP170-WW | Warm White 170 mm | 10-14 VAC | 55 W | 3300K | 4950 Ern |
PLP050-BL | Blue fixed 50 mm | 10-14 VAC | 8W | All colors and | 170 lm |
PLP100-BL | Blue fixed 100 mm | 10-14 VAC | 25 W | Tunable | 480 lm |
PLP170-BL | Blue fixed 170 mm | 10-14 VAC | 46 W | white | 1450 lm |
PLP050-TW | Tunable white 50 mm | 10-14 VAC | 14 W | 2000-99999K | 700 lm |
PLP100-TW | Tunable white 100 mm | 10-14 VAC | 27 W | 2000-99999K | 2150 lm |
PLP170 -TW | Tunable white 170 mm | 10-14 VAC | 70 W | 2000-99999K | 4250 lm |
For operation only with a safety isolation transformer
IEC Protection Class III
Minimum input voltage: 10 VAC 50 Hz
(at lamp terminals)
Nominal input voltage: 12 VAC 50 Hz
(at lamp terminals)
Maximum input voltage: 14 VAC 50 Hz
(at lamp terminals)
Power factor: > 0,90
Operation on DC voltages is NOT allowed
Maximum water temperature: +40°C Lamps have to be kept out of ice zones
Ingress protection rate: IP68 measured at 3m max depth = 3m
Remarks
Water conditions
Prevent damage to your pool lamps and wires due to unstable water conditions.
Your local government may have enacted guidelines for your pool water
conditions to apply by. If not we strongly advise the following parameter
specifications to be applied:
pH level: 6,8 – 7,6
Free Chlorine: max. 3ppm
Combined chlorine: max. 1 ppm
Water temperature: max +40°C and lamps need to be kept out of ice zones
Always adhere to the instructions provided by your chemical brand/supplier for
the correct use and application of pool chemicals.
Salt water pools, or pools fitted with a salt water chlorine generator contain
salt in the pool water. Salt is a corrosive material. Overdosage and/or
consistent levels of salt increase the possibility of deterioration of your
pool lamps and cables. As a rule of thumb, a concentration of 35gr/l salt can
be accepted when pH values are between 7,2-7,4.
In any case, we urge proper use, care and maintenance of your installation, in
order to minimize the effect of corrosion and deterioration.
Please be aware that pool lamps and cables with defects caused due to
abnormalities in the water condition are not covered by our factory warranty
Installation/maintenance
The luminaire is maintenance free
If the luminaire needs to be replaced, it needs to be completely removed from
the water
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid hazard
Box contents
ADAGIOPRO Lamp (50,100 or 170 mm)
Connection Kit ADAGIOPRO ( 513-0152 or 513-0219 )
4m Cable
Manual
Retrofit Kit (only for 170mm models)
Installation instructions
mounting face plate
mounting the connector
Connector installation
Wiring instructions Setup 1
For new installations
Each lamp is connected to the transformer by a separate cable
4m cable included in lamp package Separate cable ( not included )
Always use a toroïdal transformer
We recommend using 2 CORE cables for all Adagio Pro lights
SELECT CABLE SECTION & MAXIMUM LENGTH
| LAMP TYPE| 1,5mm2| 2,5mm2| 4,0mm2| 6,0mm2| 10mm2| | VA TRANSFORMER
(12VAC)*
---|---|---|---|---|---|---|---|---
| | | | | |
| PLP050-WH
PLP050-WW
PLP050-BL
PLP050-RGB / TW| 95m
55m| 160m
90m| 250m
145m| 350m
200m| 600m
350m| 10 VA
18 VA
| | | | | |
| PLP100-WH
PLP100-WW
PLP100-BL
PLP100-RGB / TW| 30m
20m| 50m
40m| 80m
65m| 120m
95m| 200m
165m| 33 VA
40 VA
| | | | | |
| PLP170-WH
PLP170-WW
PLP170-BL
PLP170-RGB / TW| 12m
10m| 20m
15m| 35m
25m| 50m
40m| 90m
70m| 74 VA
91 VA
STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE
-
- The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps.
These cable lenghts are calculated with worst case voltage drops in the electrical wiring.
- The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps.
Wiring instructions Setup 2
For existing or other installations
All lamps are connected to the transformer via 1 cable
4m cable included in lamp package Separate cable ( not included )
We recommend using 2 CORE cables for all Adagio Pro lights
This setup is not preferred for installations where DURALINK connected
products are used
) PLP-REM, PLP-REM-300/350, LinkTouch, DLM-450, DLM-600
SELECT CABLE SECTION & MAXIMUM LENGTH
| | ILAMP TYPE| QTY| 2,5mm2| 4,0mm2| 6,0mm2| 10mm2| VA TRANSFORMER
(12VAC)
---|---|---|---|---|---|---|---|---
| | | | | | |
| | PLP050-WH PLP050-WW PLP050-BL| 1| 160m| 250m| 350m| 600m| 10
2| 80m| 125m| 175m| 300m| 20
3| 53m| 83m| 117m| 200m| 30
4| 40m| 63m| 88m| 100m| 40
| | PLP050-RGB / TW| 1| 90m| 145m| 200m| 350m| 18
2| 45m| 73m| 100m| 175m| 36
3| 30m| 48m| 67m| 117m| 54
4| 23m| 36m| 50m| 88m| 72
| | | | | | |
| | PLP100-WH PLP100-WW PLP100-BL| 1| 50m| 80m| 120m| 200m| 33
2| 25m| 40m| 60m| 100m| 66
3| 17m| 27m| 40m| 67m| 99
4| 13m| 20m| 30m| 50m| 132
| | PLP100-RGB / TW| 1| 40m| 65m| 95m| 165m| 40
2| 20m| 33m| 48m| 83m| 80
3| 13m| 22m| 32m| 55m| 120
4| 10m| 16m| 24m| 41m| 160
| | | | | | |
| | PLP170-WH PLP170-WW PLP170-BL| 1| 20m| 35m| 50m| 90m| 74
2| 10m| 18m| 25m| 45m| 148
3| 7m| 12m| 17m| 30m| 222
4| 5m| 9m| 13m| 23m| 296
| | PLP170-RGB / TW| 1| 15m| 25m| 40m| 70 m| 91
2| 8m| 13m| 20m| 35m| 182
3| 5m| 8m| 13m| 23m| 273
4| 4m| 6m| 10m| 18m| 364
STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE
Wiring remarks
For installations with DURALINK* products
-
Third party equipment such as frequency inverters and electric motors can generate excessive noise on the 230VAC / 400VAC power line.
This noise might be injected into the adjacent 12VAC power line and disturb the power line communication towards the AdagioPro RGB lights.
Keep 230VAC / 400VAC power line cables at least 50cm separated over their full length from the 12VAC power line towards any RGB lights
Do not mix 12VAC and 230VAC / 400VAC power line cables into the same ! cable trays -
Floating cores in a multi-core cable are not allowed because it disturbs PLC communication.
We recommend using 2 CORE cables for all Adagio Pro lights to avoid PLC communication issues
() Do not mix 12VAC and 230VAC / 400VAC power line cables into the same
cable trays
**
Retrofit in PAR56 niche (only PLP170)
Color programs
RGB LAMPS
- DEEP BLUE SEA: Saturated blue
- DAYLIGHT BLUE: Light blue
- SUNSET: Slow animation orange – red
- LOVE IS IN THE AIR: Red
- FOREST SPRING: Green
- THINK PINK: Pink
- SUNSHINE: Yellow
- JUNGLE BEACH: Slow animation blue & green tints
- VOODOO: Slow animation red & purple tints
- DISCO: Fast animation lila-pink-peach-yellow-green blue
- PARTY: Fast animation blue-green-red-pink-yellow-green
- WARM WHITE: 3000K
- NEUTRAL WHITE: 6000K
- SUN WHITE: 10.500K
fixed colors
dynamic colors
white tints
TW LAMPS
7 white tints
- 3200K
- 3800K
- 5400K
- 7300K
- 14800K
- LIGHT BLUE
- BLUE
- all color programs are dimmable if PLP-REM,PLP-REM-350, LinkTouch, DLM 450 or DLM-600 are used (in PLC mode)
Synchronizing & color changing (for RGB and TW lamps only)
Manual synchronization
- Switch ON the 12 VAC line voltage and make sure that all lamps light up.
- Switch OFF the 12 VAC line voltage and wait for at least 20 sec.
- Switch ON and switch OFF
- Switch ON and switch OFF
- Switch ON
- The lamps should now all be on color program 1
for RGB lamps: fixed blue light (Deep blue Sea)
for TW lamps: 3200K
Changing colors
Quickly turn the lamps OFF and back ON
The lamp will jump to the next color program ( 1 –> 14 )
Memorizing the last color
Turn the lamp OFF for MINIMUM 20 seconds
The last chosen color has now been memorized
The use of PLP-REM, PLP-REM-350, LinkTouch, DLM-450 & DLM-600 control units enables extended features like automatic synchronisation, dimming and DMX / RS485 control
Troubleshooting
PROBLEM
|
SOLUTION
---|---
- The pool light is flickering
|
- Switch the lamps ON For RGB lamps: select the Sun White color program
- Remove the lamp from the water, unscrew the clips nut, pull back the gasket and the black cable jacket, so you can reach the brass contacts inside the connector block (do not remove the connector block)
- Measure the voltage at the lamp terminals (while the lamp is still ON)
- The voltage at the lamp should be at least 10VAC 50/60hz. If the measured line voltage is below 10VAC:
A. Check the output voltage at the transformator terminals. This voltage should be between 12VAC and 14VAC. Verify that the used transformator VA rating is sufficient for powering all connected lamps
B. If the transformator output voltage is ok, then install a thicker cable between the transformator and the lamp. (wiring instructions)
- Several pool lights in the pool show different color programs
| Make sure that all lamps are connected to the same 12VAC power line. Execute the synchronization