Si-HVACR Measurement Mobile App
User Manual
Mobile App description
The Si-HVACR Measurement MobileApp is the Sauermann mobile application
dedicated to the following HVACR portables: Si-HH3, Si-TT3, Si-PM3, Si-TI3,
Si-VH3 & Si-VV3 measuring instruments. It allows to view and record
measurements in real-time.
Main features
- Easily view different parameters
- Browse saved measurements history and data graphs (average, min & max values, etc.)
- Create reports (PDF, CSV or XML format) and add up to four (4) photos to customize them with either customer or operator information.
Minimal required configuration
For an optimal operation, the following minimum required versions must be
installed on the tablet or smartphone:
- Android 5.0
- iOS 12.4
Mobile Application installation
-
Flash the following QR code to download Si-HVACR Measurement
MobileApp application on your smartphone or tablet.
or -
Write “Si-HVACR Measurement Mobile App” in the search bar then validate.
-
Download the application.
-
Follow your mobile device indications.
http://qrcode.inair.cloud/sauermann/hvacr_MobileApp
Download the Si-HVACR
Measurement MobileApp
Google Play and the Google Play logo are trademarks of Google LLC.
App Store is a service mark of Apple Inc.
Safety instructions
Si-HVACR Measurement MobileApp application
Exclusions and restrictions of liability
The application operation is under the exclusive customer or user entity
responsibility, who acknowledges using this system at his/her own risk. The
customer or user entity explicitly excludes Sauermann, and every other company
through which it could have been sold of any kind of responsibility or
warranty regarding any direct, indirect, accidental, consecutive, or non-
consecutive damage that could have been subjected, for some or all, by partial
or total non-respect, voluntary or involuntary, of recommendations, conditions
and prerequisites indicated hereafter.
Exclusions and warranty limitations
Sauermann guarantees that the application, which is made available for the
customer or user entity through digital content such as a DVD or a downloaded
link as indicated in our commercial documents, is in a state enabling its
correct installation and operation. Within the limits of the law, this
warranty is exclusive. Therefore, we do not guarantee the application
operation after its availability to the customer or user entity of this
digital support or downloaded link. There is no other explicit or implicit
guarantee regarding the application’s merchantability and fitness for a
particular purpose. The customer or user entity acknowledges accepting all the
present guarantee limitations or exclusions.
Symbols used
For your safety and in order to avoid any damage to the device, please follow
the procedure described in this user manual and read carefully the notes
preceded by the following symbol:
The following symbol will also be used in this user manual:
Please read carefully the information notes indicated after this symbol.
Start with the application
Launch the Si-HVACR Mobile App
Launch the application by pressing this icon.
Activate the wireless communication on the instrument
-
The device is turned on.
-
Press simultaneously ON/OFF & HOLD keys to activate or deactivate wireless communication.
The wireless communication icon flashes on the instrument screen.
The icon becomes fixed when the instrument is paired to the tablet or the smartphone. -
Si-TI3 only: turning the device on automatically activates wireless communication.
Pair the device to the smartphone/tablet
-
Click “Search for devices“.
The detected devices are displayed. -
Select the device to pair then click “Connect“.
-
The real-time measurement values are displayed on the smartphone/tablet.
Device information
From the real-time values display:
Check the battery level of the device
Display the device information: name, serial number, and firmware version.
- Click ‘‘Disconnect’’ to unpair the device.
- Click ‘‘Yes’’ to confirm disconnection.
Real-time displayed values on App
- Si-HH3 thermo-hygrometer: humidity, temperature, dew-point, wet temperature, absolute humidity, enthalpy, mixing ratio
- Si-TI3 infra-red thermometer: infrared temperature, ambient temperature
- Si-TT3 dual input thermometer: T1 thermocouple temperature & T2 thermocouple temperature, delta temperature
- Si-PM3 digital differential pressure manometer: pressure, air velocity, airflow
- Si-VH3 hotwire thermo-anemometer: air velocity, airflow, ambient temperature
- Si-VV3 vane thermo-anemometer: air velocity, airflow, temperature
Customize the parameters display: display, hide, set the parameter location.
Directly access the options of the air velocity & airflow parameters.
See more details in Chapter 4 – Options settings, Measures.
Display the list of parameters that can be added to the main display.
Select the required parameter then confirm with ‘‘Select’’.
Options settings
Access the options settings from the main screen displaying real-time data.
When options are set, click ‘‘Close’’.
Device
- If required, tick the wireless connection help box to activate it.
- Click on ‘‘Delete devices found’’ to empty the list of detected devices.
Measures
-
Set the atmospheric pressure.
Default value: 1013.2 hPa -
Pressure settings for Si-PM3:
In ‘‘Pressure’’, set the integration value.
Click ‘‘Validate’’ to confirm. -
Air velocity settings for Si-PM3, Si-VV3 & Si-VH3:
In ‘‘Air velocity’’, select the required air velocity sensor & set the compensation temperature.
Add a customized air velocity sensor:
Add a name and click validate.
Set the coefficient of the air velocity sensor then confirm with validate. -
Airflow settings for Si-PM3, Si-VV3 & Si-VH3:
In ‘‘Airflow’, select the air vent type (rectangular or circular) and the air vent dimensions.
Add customized air vent dimensions:
Fill in the air vent width & length then validate.
-
Tick the ‘‘K Factor’’ box to activate it.
Select the K factor value to apply.
Add a customized K factor value then validate.
Delete an existing customized item (air velocity sensor, air vent type, or K factor):
Select the items to delete.
Click ‘‘Delete’’ to confirm.
Select the measuring units
For each parameter, select the unit to be displayed on the real-time data
screen:
- Click on the parameter then select the required unit.
- Confirm with ‘‘Select’’.
PARAMETER | AVAILABLE UNIT |
---|---|
Temperature | °C / °F |
Pressure | Pa / hPa / mmH2O / inH2O / PSI / inHg |
Atmospheric pressure | hPa / mbar |
Air velocity | m/s / fpm / km/h / mph |
Airflow | m ³/h / m³ /s / m³ /min / cfm |
Distance | mm / in |
Operator
-
Fill in the information on the operator: name, address, e-mail, phone.
Click ‘‘Clear information’’ to empty all operator fields. -
Add a logo to customize your measurement reports:
Click ‘‘Logo’’ then select an existing photo or take a photo.
Click ‘‘Delete’’ to remove the selected picture.
About
- ‘‘Read the manual’’: allows downloading the user manual
- ‘‘Languages’’: select the required language.
- ‘‘Version’’: consult the application version number.
- ‘‘Licences’’: display the licenses.
Datasets
Record & save measured values
Start the record of measured values.
The elapsed time is displayed on top of the screen.
Stop the record of measured values.
-
Save the record:
Add a recording name and a description if needed, then click ‘‘Save’’.
Click ‘‘Cancel’’ if you do not need to save this record. -
Open the data record:
Click ‘‘Yes’’ to open the data record or ‘‘No’’ to go back to the measurements display.
Open the data record to display a summary with:
- the recording name
- the recording duration
- the minimum, maximum, average & standard deviation values for each parameter displayed.
Directly export the dataset.
See next page: ‘‘Export the measured values’’.
Display the saved datasets and reports
Open the list of saved datasets and reports from the real-time values display screen.
-
Click ‘‘Datasets’’ to display all the saved datasets:
In each folder, find the measurement records carried out for this dataset.
Click on a record to display its summary. -
Click ‘‘Reports’’ to display the list of saved reports:
Select how to display the list of reports: ascending/ descending alphabetical, chronological, or inversly chronological.
Click on a report to display it.
Delete existing files: select the items to delete then click ‘‘Delete’’ to confirm.
Export the measured values
Export data as a measurement report, directly from the data
summary screen, or from the
‘‘Datasets’’ list selecting the required recording.
- Fill in the customer information.
- Check that the operator information is correct.
- Add comments if needed.
- Select the required format: PDF, CSV or XML.
- PDF report: select the items to include in the report.
Tick ‘‘Include table of values’’ and/or ‘‘Include graph’’ if needed.
It is also possible to add up to 4 photos to the report to customize it with
either customer or operator information.
- CSV or XML reports: tick ‘‘Copy to clipboard’’ to copy the data and/or tick ‘‘Include a table of values’’ to add the values table to the report.
- Once the export is done, click ‘‘Yes’’ to send or share the report, or ‘‘No’’ to cancel.
View mode
From the real-time values display, during a measurement record, or from the
record summary screen, use the following icons to switch to the required view:
Table of values
Graph
Real-time display
Sauermann Industrie
ZA Bernard Moulinet
24700 Montpon
France
T. +33 (0)5 53 80 85 00
services@sauermanngroup.com
Sauermann UK
Units 7-9, Trident Business Park
Amy Johnson Way
Blackpool – FY4 2RP
T. +44 (0) 870 950 6378
F. +44 (0) 870 950 6379
info.uk@sauermanngroup.com
Sauermann Australia
Unit 4/14 Rodborough Road,
Frenchs Forest, NSW 2086
T. (+612) 8880 4631
© 2019 Sauermann. All rights reserved. Sauermann & Si-HVACR Measurement MobileApp are the exclusive property of Sauermann. Non contractual document. The product’s functionalities and visual appearances can be modified without prior notice. Smartphones or tablets are not supplied with Sauermann products.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>