FORSTER TECHNIK Automatic calf feeder 2.1 SynchroFeed User Guide
- June 6, 2024
- FORSTER TECHNIK
Table of Contents
FORSTER TECHNIK Automatic calf feeder 2.1 SynchroFeed
This document provides a brief overview of how to set up a single or quadruple IFS.
How To Use
-
Mount the SynchroFeed feeding station
Not higher than the teat and near to the automatic feeder. The maximum length of the suction hose with pump = 8m. -
Establish ground connection
-
Insert the pump hose into the servo pump
The pump hose (from Förster-Technik) has to lie against the pumps housing in the top half. -
Mount the power supply unit
-
Mount the pressure sensor
Close to the teat but min. 35 cm below. -
Connect the antenna to the IFS
-
Connect the suction hose & prepare rinse return flow Per feeding station a complete suction hose should not be longer than 8 m.
-
Connect IFS and feeder via CAN-bus cable
-
Connect the power supply
-
IFS feed station
-
Calibrate the IFS
-
Perform cleaning Connect suction hose and flushing return line.
-
Further Information
- The pump speed can be adjusted for each individual group.
- Only use Förster-Technik teats with open ends. Don‘t use teats with a cross pump.
- Has the suction hose been replaced by a technician if damaged?
- Don‘t ignore calibration warnings. If warnings come back daily, check the pump and replace the pump hose by a technician if necessary.
- Clean the membrane of the pressure sensor at least every 3 months with warm water. Replace if damaged or out of shape.
- Only use Förster-Technik hoses.