FORSTER TECHNIK 1.4 Combi Automatic Calf Feeder User Guide

May 15, 2024
FORSTER TECHNIK

FORSTER TECHNIK LOGO QUICK START GUIDE
Automatic calf feeder – CombiFORSTER TECHNIK 14 Combi Automatic Calf
Feeder

1.4 Automatic calibration

This document provides a brief overview about what settings should be made for automatic calibration and what errors can occur.
1. Before calibration
Make sure mixer is not touching feeders housing.
2. Check that the hoses are fixed with the O-ring
3. Loosen or remove locking screw of the mixer

FORSTER TECHNIK 14 Combi Automatic Calf Feeder -
calibration

4. Settings
Times when the calibration should be carried out automatically.

FORSTER TECHNIK 14 Combi Automatic Calf Feeder -
Settings

5. Check calibration scale

FORSTER TECHNIK 14 Combi Automatic Calf Feeder - calibration
scale

6. Manual start of automatic calibration

FORSTER TECHNIK 14 Combi Automatic Calf Feeder - automatic
calibration

Two control weighings are carried out automatically and an average value is calculated. Confirm this with the Enter key.

Troubleshooting

7. Warning: Calibration water HE/boiler

  • Check water valves via diagnosis.
  • Check if station or drain valves are leaking.
  • Change calibration time to a moment when action can be observed (see 4).

8. Warning: Calibration milk

  • Check milk filter.
  • Check milk valve via diagnosis.
  • Check milk pump.
  • Check if station or drain valves are leaking.
  • Change calibration time to a moment when action can be observed (see 4).
    Note: Auto calibration time for milk is an “from“ time. Calibration is done with next entitled calf that enters station.

9. Warning: Calibration milk powder

  • Check powder supply via diagnosis.
  • Check powder supply outlet visually.
  • Check if station or drain valves are leaking.
  • Change calibration time to a moment when action can be observed (see 4).
    Note: Auto calibration time for milk powder is an “at” time. Calibration is done with next entitled calf that enters station.

10. Warning: Calibration

  • 120 days after the last calibration of detergent, additives and concentrate.
    Or if calibration value differs too much from the value of the last calibration for water HE, water boiler, MP and milk.

  • Confirm warning with ENTER button.

  • Recalibrate components that are displayed.

  • Check with arrow left or right if there are more components to be calibrated.

11. Procedure if checking the calibration scale failed

  • Readjust the scale via diagnosis.
  • Make sure the feeder is in a stable position.
  • Make sure potential equalization is done correctly.
  • Have it checked by a technician that the card of the calibration scale is correctly seated on the main board.

FORSTER TECHNIK 14 Combi Automatic Calf Feeder - calibration scale
failed

This checklist refers to the basic equipment of the calf feeder. Not all available functions of the automatic feeder or the extensions can be shown.
For detailed information and valid warnings as well as safety instructions, please refer to the instructions manual. (Status 21/07)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FORSTER TECHNIK User Manuals

Related Manuals