Aquaguard Active Copper Maxx Water Purifier User Manual

June 6, 2024
Aquaguard

Aquaguard Logo

Aquaguard Active Copper Maxx Water Purifier

Aquaguard Active Copper Maxx Water Purifier

Aquaguard® Select brings you India’s first water purifier with two breakthrough technologies – BiotronTM and Active Copper MaxxTM, that help release the natural goodness of water and fortify it with essential natural minerals.
Active Copper MaxxTM technology fortifies drinking water by adding essential natural minerals such as Calcium, Magnesium, Copper and Zinc and balancing the pH level, making it truly the healthiest water.
The revolutionary BiotronTM technology breaks water molecules to release their nutrients, so that every cell of your body can absorb the wholesome goodness of water easily.
Bring home the advantage of revolutionary technology, only with Aquaguard.
IS 10500: 2012 Drinking Water Specification (Acceptable Limit).

Installing Your Water Purifier

Make sure that your water purifier is installed by a trained Eureka Forbes Service Technician only.

  1. Input water must be tested for Total Dissolved Solids (TDS).
  2. Install your water purifier in a suitably ventilated place.
    • Keep it away from direct sunlight, heating devices or areas below freezing temperature.
    • You can wall mount it with concealed wiring, within a duct in the wall, with only the front visible.
  3. Ensure that the input water temperature is in the range of 10°C to 40°C.
    • Do not connect to a hot water tap as it can damage the filters.
  4. Make sure that the tap water pressure is from 0.3 to 2.0 kg/cm², installation of a PRV is mandatory.
  5. Once the flushing is over, switch ON the water flow of the product and allow at least 1-2 liters of water to drain. Now your product is ready to use.
  6. Before fixing the fuse, ensure that the hot tank is filled with water. Do not fix the fuse without filling the hot tank.

Aquaguard ® Select Hot, Warm & Ambient – Operation Guide

Step 1| Power On| Blue / Yellow / Red coloured LEDs glow for 1 second in sequence
Purification process for 30 seconds to ensure 100% protection
Step 2| Purification On| All LED’s glow Blue
Step 3| Dispense Mode| Mode 1| Mode 2| Mode 3
Ambient / Room Temperature| Warm (500 ml)| Hot (500 ml)
approx. 45°| approx. 80°
Step 4| Start Dispense| Touch Water Drop Icon| Touch Warm Icon| Touch Hot Icon
Blue LEDs Blink in Sequence, Purified Water gets Dispensed.| Alternate Yellow LEDs Blink Duration: Approx. 2 mins| Alternate Red LEDs Blink Duration: Approx. 4 mins
LEDs Turn Solid Yellow Once Water is Warm| LEDs Turn Solid Red Once Water is Hot
Touch Child Lock Icon
Touch & Hold Water Drop Icon(within 10 secs)
Yellow LED glows in sequence| Red LED glows in sequence
Purified Warm Water gets dispensed| Purified Hot Water gets dispensed
| | | Remove finger from Water Drop icon
Note: LED INDICATES RED for HOT water and YELLOW for WARM water.

PURIFICATION PROCESS OF AQUAGUARD® SELECT CLASSIC + UV HOT

Diagram

NOTE: THIS IS A SCHEMATIC ILLUSTRATION OF THE PRODUCT TO GIVE A VISUAL SCHEME OF WORKING OF PRODUCT. THIS IS NOT AN ACTUAL ENGINEERING DRAWING OF THE PRODUCT.

INDICATION CHART TO USE AQUAGUARD® SELECT CLASSIC + UV HOT

INDICATION CHART TO USE AQUAGUARD SELECT CLASSIC + UV
HOT

TECHNICAL SPECIFICATIONS

# Technical Parameters Specifications
1 Model Aquaguard® Select Classic + UV HOT

PRODUCT SPECIFICATIONS
1| Dimension (WxDxH) in mm| 313x167x423
2| Net Weight| 6.2 kgs. (Approx.)
3| Purification Technology| UV
4| Standard Filtration Supplied| Combination Cartridge, UV Lamp, Active
Copper Maxx Cartridge, Biotron Cartridge
5| Flow Rate (Approx.)| Ambient Water: 1.5 Liters / min @ 1bar pressure Hot / Warm water : 1 Liter / min @ 1 bar pressure
ELECTRICAL SPECIFICATIONS
1| Operating Voltage Range| 150V AC to 280V AC, 50Hz
2| Power Supply| External: 230V AC, Internal: 12V DC, 1.7 Amps
3| Power Rating| 20 Watts max in Ambient mode & 775 Watts in Hot / Warm mode
4| UV Lamp| 11 Watts
5| UV Lamp Life| 8,000 Burning hours (As per UV Lamp Manufacturer’s Specifications)
6| Solenoid Valve| 12V DC
HOT TANK DETAILS
1| Tank Volume| 500 ml.
2| Temperature Sensing| Thermistor (Electronic Thermostat)
RECOMMENDED INPUT WATER PARAMETERS
1| Input Water Pressure (min-max)| 0.3 kg/cm² – 2.0 kg/cm²
2| Input Iron (max.)| 0.3 PPM
3| Input Water Turbidity (max)| 5NTU
4| Chlorine Content (max)| 0.2 PPM
5| TDS Range| Up to 200 PPM

PRECAUTIONS

  • To get hot/warm water, touch the respective switches
  • After completing the heating/warming process, the indication will display that the product is ready to dispense hot/warm water. If hot/warm water is dispensed before completing this process, the output water will not be hot (80°C)/warm (45°C) respectively.
  • To dispense hot/warm water, press the child lock and hold the dispense switch
  • Do not let the glass/cup/container overflow with hot water while collecting water.

Note: Unless the child lock function is activated and the dispense switch is pressed & held within 10 seconds, hot/warm water will not be dispensed.

SAFETY FEATURES

  • Hot water above 50°C may cause burns, due to scalding if touched with bare hand. Aquaguard Select “Hot” has an in-built safety feature, as “CHILD LOCK” especially for the safety of children/aged.
  • Electronic thermostat cut-off is provided to prevent over heating of hot/warm water.
  • As an additional safety measure, mechanical thermostat is provided which needs a manual intervention to check and restart the product in case the thermostat trips due to overheating.

TIPS FOR SAFETY AND MAINTENANCE OF YOUR AQUAGUARD® SELECT CLASSIC +UV HOT

  1. Read attentively and understand the purifier and its functions before use.
  2. Installation and service has to be conducted by authorized persons from Eureka Forbes Limited only.
  3. Install the purifier at a location with more ventilation.
  4. Ensure that the purifier is installed in a dry place. Do not expose to direct sunlight or heat sources.
  5. Ensure that the installation height is ideal for comfortable reach for the user to avoid any accidental hot water spill. (Approx. 5 feet)
  6. Connect the purifier to 230V AC power socket, duly grounded. Use 500VA voltage stabilizers in case the voltage fluctuates.
  7. Discard about 10 litres of water after installation or after replacing the filter cartridges.
  8. Do not remove or insert the plug with wet hands.
  9. Replace the filters when the end of life indicator is displayed by your purifier.
  10. Ensure that the filter cartridges and spares used during service/replacement, are genuine and from Eureka Forbes only.
  11. Always switch off and disconnect the power plug before maintenance or cleaning.
  12. In case of any damage or incorrect functioning, immediately contact an authorized service Centre of Eureka Forbes Limited. Do not to repair on your own.

WARRANTY TERMS & CONDITIONS

  1. The Products are warranted against manufacturing defects for a period of twelve (12) months from the date of original purchase.
  2. The Customer will notify the Company in writing promptly of any defects noticed and give the Company or its authorized agent adequate opportunity to inspect test and remedy them for which the Customer will deposit the goods at its own expense, if so, required by the Company with the Company’s Office/Service Centre along with the original invoice in the city where they are sold.
  3. The Inspection and Test Report of the company’s office/service Centre will be final and binding under the warranty for determining defects, repairs/alterations required or carried out or certifying work of the goods thereafter.
  4. Aquaguard® may require initial setting, post-installation, depending on varying water conditions and power supply. In case of any service requirement, post-installation, please contact the company’s service centre.
  5. The company or its authorized agent will be entitled to retain any defective part replaced under the warranty.
  6. Notwithstanding anything to the contrary contained or implied by this warranty:
    • The company’s liability under this warranty shall be limited to the first sale of the goods by the company to the customer and will not apply or extend to any secondary sale of goods by the customer.
    • The company’s liability under this warranty shall be limited only to defects in the goods which occur under the conditions of normal operation of the goods and their proper and prescribed use. The warranty does not cover or extend to defects which are determined by the company or its authorized agents as occurring or resulting from or attributable to negligence, abuse, misuse, faulty care, operation or maintenance or repairs, alterations to the goods or any part thereof by others or the use of the goods on electrical supply for which they are not designed, or damage caused by lightening or other electrical disturbances or interruptions, dismantling or reinstallation at a different location.
    • The company’s liability under this warranty shall remain valid only if the goods are duly installed by the company or its authorized agency at the location specified in the invoice and such installation is undertaken by the company or its authorized agent or franchise.
    • Consumable items mentioned in the consumables table are subject to normal wear and tear are not covered by this warranty. Please refer model specific components given in the user manual under the table ‘consumable cartridges’.
    • Reverse Osmosis Membrane warranty is for a period of 1 year (or) 6,000 liters (whichever is earlier) from the date of installation, on the condition that the input water is as per the standard test conditions for RO variants (provided in the section ‘Technical specifications table’), mentioned in the user manual. If the RO membrane gets clogged within warranty period, it will be cleaned/repaired/replaced free of charge as deemed fit by the company authorized service person/Centre after inspection. (At applicable for RO models only.)
    • The customer will have no claim against the company, its employees and its authorized agents or franchise under or pursuant to this warranty in respect of death or injury to the customer or any other person or loss or damage to any property caused by or due to equipment failure, breakdown or accident, fire or operation or utilization of the goods otherwise than in accordance with the user manual or by due to any other cause or circumstances beyond the control of the company.
    • The company’s liability, under this warranty, shall in no event and under no circumstances exceed the price paid by the customer to the company for the goods stated in the invoice.
General

For the purpose of this warranty, the following expressions shall have the following meanings respectively:

  1. The ‘Goods’ shall mean the goods described in the Order Form.
  2. The ‘Customer’ shall mean the original purchaser of goods from the company.
  3. The ‘Company’ shall mean EUREKA FORBES LIMITED.
  4. Aquaguard® means and includes Aquaguard®, Aquaguard® Select and Sure from Aquaguard®.
  5. ‘General Terms & Conditions’ shall mean the terms and conditions agreed upon by the customer and the company printed on the Order Form.
  6. ‘Invoice’ shall mean the invoice issued by the company to the customer describing the goods and indicating, inter alia, the total purchase price thereof and name of the customer.
  7. ‘User Manual’ shall mean the instructions for Installation, use and maintenance provided through QR code along with Product supplied by the company.
  8. EFL reserves the right, in its absolute discretion, to change, alter or discontinue and alter the terms and conditions from time to time without any prior notice.
  9. Any disputes are subject to Mumbai Jurisdiction only.
Post-warranty
  1. The customer may be offered a yearly Service Contract at the prevailing company rates and terms.
  2. In case the customer does not wish to enter the Service Contract, he/she has the option of calling the company’s service Centre having his Aquaguard® services on an actual basis, i.e., by paying the labor cost and spares needed to attend to that service/complaint call at the prevailing company rates. Such service will be rendered by the company in towns/places where the company has its service Centre.
  3. If during such servicing it is necessary for the company to replace or repair defective components or parts, the customer shall be required to pay for the same as per the company’s prevailing price list.
  4. Eureka Forbes limited reserves the right to offer annual maintenance contract/ensure availability of spares only up to 7 years from the date of invoice.