INTRODUCTION-POE-MCBASIC-LFPT
ABOUT POE-MCBASIC-LFPT
The PoE Mc Basic with LFPT is a solution for network applications that requires Power-over-Ethernet (PoE) (IEEE802.3af) for locations inside buildings where PoE Power Sourcing Equipment (PSE) is required to power an Ethernet device. The standalone unit offers 3 ports: a 100 Mbps fixed fiber transceiver (1×9) uplink for the network connection, one 10/100Base-T copper port that provides PSE/PoE, and one standard Ethernet 10/100 Mbps copper port.
This unmanaged unit provides both power and data to a remote device over a
standard CAT5 copper line, eliminating the need for a power connection to the
remote device. The PoE Mc Basic with LFPT provisions up to 15.4 Watts on one
PSE copper port, and is powered by an internal power supply, supporting
100-240 VAC. The copper port auto negotiates to the connected device’s speed
and duplex mode: 10 Mbps or 100 Mbps, HDX or FDX (including Flow Control). The
PoE McBasic with LFPT supports jumbo frames up to 10240.
NOTE : Some options require items that are sold separately, available
from B+B SmartWorx.
INSTALLATION
PoE Mc Basic with LFPT is a compact media converter that can be installed as a
standalone, table-top device, with rackmount ears, or using a wallmount
bracket. The rackmount ears and wallmount bracket are optional accessories
available from B+B SmartWorx.
Several models of the PoE Mc Basic with LFPT support single-strand fiber for
operation. Since single-strand fiber products use optics that transmit and
receive on two different wavelengths, single-strand fiber products must be
deployed in pairs. The two connected products must also have the same speed
and distance capabilities.
DIP SWITCH CONFIGURATION
DIP
Switch
|
Name
| Description|
Default
|
DIP Switch
---|---|---|---|---
1| PoE Reset| ON forces Port 2, PSE/PoE, to OFF on
LOS of fiber input
| OFF|
2| LFPT Port 1| ON enables LFPT for Port 1 and the FX Port.| OFF
3| LFPT Port 2| ON enables LFPT for Port 2 and the FX Port.| OFF
4| Factory| Do not change.| OFF
5| Factory| Do not change.| OFF
6| Factory| Do not change.| OFF
7| Factory| Do not change.| OFF
8| Factory Set| Do not change.| OFF
POE RESET DSW
When set to ON, it will force the PSE output power on the copper port OFF when the LINK state is lost on the fiber segment. By default, the DSW is set to OFF.
LFPT DIP SWITCHES
There are two DIP Switches for Link Fault Pass Through (LFPT), each located near the copper (TX) ports. LFPT is a diagnostic feature that, when enabled, allows a fault to be passed through the unit. When enabled, if link is lost on the FX (fiber) port, the transmit on the TX (copper) port is disabled. If link is lost on a TX port, the transmit on the FX Port is disabled.
NOTE: Fault DIP Switches PoE Reset, LFPT Port 1 and LFPT Port 2: only one fault condition is recognized at a time. The first fault condition to occur is in charge. So, if TX Port 1 has no link and then the FX Port loses link, the loss of TX on Port 1 link causes the FX Port to disable the transmit.
FAR END FAULT
Far End Fault (FEF) is a troubleshooting feature for the fiber segment that is permanently enabled. If one strand of fiber fails, the error is reported back down the other strand of fiber in the form of an FEF signal.
LED OPERATION
The PoE-McBasic LFPT includes LEDs for three ports, as shown below:
NOTE: The fixed twisted pair port labeled PSE is the only port capable of providing Power Over Ethernet.
LED Functions
FLT| Glows red when a fault has been detected on the unit.
LNK| Glows green with a valid link.
100 Mbps| Glows green when SFP is running at 100Mbps.
PWR| Glows green when unit is powered.
RJ-45 LED Functions
LNK/ACT (TX1, TX2)| Glows green with a valid link.
Blinks green when activity is detected.
__
__
PSE (TX2)
| Glows green when port is supplying PoE power.
Blinks green during fault conditions: 1 Hz flashes to indicate an overload or short; 4 Hz flashes to indicate out-of-range voltage or over-temperature.
Off if the port is not supplying power.
FDX (TX1)| Glows amber when port is running full-duplex.
TROUBLESHOOTING
- PWR LED glows green when the unit is powered. If this LED is not lit, contact B+B SmartWorx Technical Support.
- Blinks green during fault conditions: 1 Hz flashes to indicate an overload or short; 4 Hz flashes to indicate out of range voltage or over-temperature.
- The PSE LED should maintain solid green to indicate consistent power. Check the PD device and its requirements.
- The following table lists the pin configuration for the RJ-48 connector.
RJ-45 PINOUTS
The following table lists the pin configuration for the RJ-48 connector.
Pin#| Signal Name
1000M
| Signal Direction
10/100M
| PoE (ALT-B)
---|---|---|---
1| TXD1+| Out|
2| TXD1-| Out|
3| RXD2+| In|
4| D3+| | +V
5| D3-| | +V
6| RXD2-| In|
7| D4+| | -V
8| D4-| | -V
SPECIFICATIONS
Ethernet Connections
- 10/100BaseT
- Auto Negotiation
- Auto Cross
- Flow Control
- 10240 MTU
- Full Line-Rate Forwarding
Input Specifications
100 to 240 ±10% VAC Input, 50/60 Hz, 0.5A to 0.2A
Operating Temperature
0 to +50 °C (+32 to +122 °F)
Storage Temperature
-40 to +85 °C (-40 to +185 °F)
Humidity
5 to 95% (non-condensing); 0 to 10000 ft. altitude
Dimensions
3.71H x 12.09W x 18.59D cm (1.46H x 4.76W x 7.32D in)
Power Characteristics
Consumes <10 Watts (heating) plus PSE power IEEE802.3af Power to Field <
15.4 Watts
Standards Compliance
- IEEE 802.3af Power-over-Ethernet
- IEEE 802.3 Ethernet Standards
- IEEE 802.3u Auto Negotiation
- RFC-2474
- RFC-2475 DiffServ QoS
B+B SMARTWORX TECHNICAL SUPPORT
- USA/Canada: 1 800-346-3119 (Ottawa IL USA)
- Europe: +353 91 792444 (Ireland / Europe)
- Email: support@advantech-bb.com
- Web: www.advantech-bb.com
STATEMENTS, PRECAUTIONS, GUIDELINES, REGULATORY
FCC RADIO FREQUENCY INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class
A computing device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which the user
will be required to correct the interference at his own expense.
Any changes or modifications not expressly approved by the manufacturer could
void the user’s authority to operate the equipment.
The use of non-shielded I/O cables may not guarantee compliance with FCC RFI
limits. This digital apparatus does not exceed the Class A limits for radio
noise emission from digital apparatus set out in the Radio Interference
Regulation of the Canadian Department of Communications.
POE PRECAUTION (INSIDE BUILDING INSTALLATION ONLY)
The PoE Mc Basic with LFPT is for inside-a-building installation only. It cannot be installed in an outside-a-building environment, as it cannot meet the PoE requirements, per the PoE standard. If installing the device outside, serious damage can occur and void any B+B SmartWorx warranty.
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products.
- Do not remove unit from its protective packaging until ready to install.
- Wear an ESD wrist grounding strap before handling any module or component. If the wrist strap is not available, maintain grounded contact with the system unit throughout any procedure requiring ESD protection.
- Hold units by the edges; do not touch the electronic components or gold connectors.
- After removal, always place boards on a grounded, static-free surface, ESD pad or in a proper ESD bag. Do not slide the modules or stand-alone units over any surface.
WARNING! Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage. Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices.
FIBER OPTIC CLEANING GUIDELINES
Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules.
- Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier; low-quality components can cause many hard-to-diagnose problems in an installation.
- Dust caps are installed at the factory to ensure factory-clean optical devices. These protective caps should not be removed until the moment of connecting the fiber cable to the device. Should it be necessary to disconnect the fiber device, reinstall the protective dust caps.
- Store spare caps in a dust-free environment such as a sealed plastic bag or box so that, when reinstalled, they do not introduce any contamination to the optics.
- If you suspect that the optics have been contaminated, alternate between blasting with clean, dry, compressed air and flushing with methanol to remove particles of dirt.
REGULATORY, STANDARDS, COMPLIANCES
UL/cUL: Listed to Safety of Information Technology Equipment, Including Electrical Business Equipment.
Class 1 Laser product, Luokan 1 Laserlaite, Laser Klasse 1, Appareil A’Laser de Classe 1
CE: The products described herein comply with the Council Directive on
Electromagnetic Compatibility (2004/108/EC) and the Council Directive on
Electrical Equipment Designed for use within Certain Voltage Limits
(2006/95/EC). Certified to Safety of Information Technology Equipment,
Including Electrical Business Equipment. For further details, contact B+B
SmartWorx.
European Directive 2002/96/EC (WEEE) requires that any equipment that bears
this symbol on product or packaging must not be disposed of with unsorted
municipal waste. This symbol indicates that the equipment should be disposed
of separately from regular household waste. It is the consumer’s
responsibility to dispose of this and all equipment so marked through
designated collection facilities appointed by the government or local
authorities. Following these steps through proper disposal and recycling will
help prevent potential negative consequences to the environment and human
health. For more detailed information about proper disposal, please contact
local authorities, waste disposal services, or the point of purchase for this
equipment.
© 2018 B+B SmartWorx – powered by Advantech. All rights reserved. The
information in this document is subject to change without notice. B+B
SmartWorx assumes no responsibility for any errors that may appear in this
document. PoE-McBasic is a trademark of B+B SmartWorx. Other brands or product
names may be trademarks and are the property of their respective companies.
Documentation Number: PoE-McBasic_LFPT_4718m
© 2018 B+B SmartWorx – powered by Advantech. All rights reserved. The
information in this document is subject to change without notice. B+B
SmartWorx assumes no responsibility for any errors that may appear in this
document. PoE-Mc Basic is a trademark of B+B SmartWorx. Other brands or
product names may be trademarks and are the property of their respective
companies.
Documentation Number: PoE-McBasic_LFPT_4718m
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>