Milesight UG65 Semi Industrial LoRaWAN Gateway User Guide

June 6, 2024
Milesight

UG65
Quick Start Guide

Xiamen Milesight IoT Co.,
Ltd.UG65 Quick Start Guide

Safety Precautions

Milesight will not shoulder responsibility for any loss or damage resulting from not following the, instructions of this operating guide.

  • The device must not be modeled in any way.
  • Do not place the device close to objects with naked flames.
  • Do not place the device where the temperature is below/above the operating range.
  • Do not power on the device or connect it to another electrical device when installing.
  • Check lightning and water protection when used outdoors.
  • Do not connect or power the equipment using cables that have been damaged.

Related Documents
This Quick Start Guide only explains the installation of the Milesight UG65 LoRaWAN ® Gateway. For more functionality and advanced settings, please refer to the relevant documents below.

Document|

Description

---|---
UG65 Datasheet| Datasheet for UG65 LoRaWAN® Gateway.
UG65 User Guide| Users can refer to the guide for instruction on how to log in to the web GUI, and how to configure all the settings.

The related documents are available on the Milesight website: https://www .milesight-iot.com

Declaration of Conformity
UG65 is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.

For assistance, please contact
Milesight technical support:
Email: iot.support@milesight.com
Tel: 86-592-5085280
Fax: 86-592-5023065

Revision History

Date Doc Version Description
Aug. 31, 2020 V1.0 Initial version
Nov. 24, 2020 V2.0 Layout replace

www.milesight-iot.com

1. Packing List

Before you begin to install the UG65 gateway, please check the package contents to verify that you have
received the items below.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Packing
List

If any of the above items is missing or damaged, please contact your sales representative.

2. Hardware Introduction

2.1 Overview
A. Front Panel

  1. LED Area
    POWER: Power Indicator
    STATUS: System Indicator
    Lora: LoRa Indicator
    Wi-Fi: Wi-Fi Indicator
    LTE: Cellular Indicator
    ETH: Ethernet Port Indicator

  2. Lora Antenna Connector (only for external antenna version)
    B. Rear Panel

  3. Bracket Mounting Screws

  4. SIM Slot

  5. Type-C Port

  6. Ethernet Port (PoE)

  7. Power Connector

  8. Reset Button

  9. Waterproof Silicone

  10. Cable Groove

2.2 Dimensions (mm)

Milesight UG65 Semi Industrial LoRaWAN Gateway -
Dimensions

2.3 LED Indicators

LED| Indication| Status|

Description

---|---|---|---
POWER| Power Status| Off| The power is switched off
On| The power is switched on
STATUS| System Status| Blue Light| Static: the system is running properly
Red Light| The system goes wrong
Lora| Lora Status| Off| Packet Forwarder mode is running off
Blue Light| Packet Forwarder mode is running well
Wi-Fi| Wi-Fi Status| Off| Wi-Fi is disabled
Blue Light| Wi-Fi is enabled
LTE| Cellular Status| Off| SIM card is registering or fails to register
(or there are no SIM cards inserted)
Blue Light| Blinking slowly: SIM card has been registered
and is ready for dial-up
Blinking rapidly: SIM card has been registered
and is dialing up now
Static: SIM card has been registered and dialed
up successfully
ETH| EthernetPort Status| Off| Disconnected
Blue Light| Static: Connected

2.4 Reset Button

Function

|

Description

---|---
STATUS LED| Action
Reset| Static Blue| Press and hold the reset button for more than 5 seconds.
Static Blue→Rapidly Blinking| Release the button and wait.
Off → StaticBlue| The gateway resets to factory default.

 3. Hardware Installation

3.1 SIM Card Installation
A. Use a screwdriver to open the protective cover on the back panel of UG65.
B. Insert the SIM card into the device according to the direction icon on the device.
Note:

  • If you need to take out the SIM card, press into the SIM card and it will pop up automatically.
  • UG65 does not support hot-plugging (also called hot swapping). please turn off the power before you insert or take off cards.
    Milesight UG65 Semi Industrial LoRaWAN Gateway
-nstallation

3.2 Ethernet Cable & Power Cable Installation

A. Connect the Ethernet cable and power cable to corresponding interfaces.
B. Pass two cables through the waterproof silicone and slid into the grooves.
C. Screw the protective cover back to the device.

UG6x can also be powered by 802.3af standard PoE injector or other PoE devices. If both are connected, DC power is preferred.
Note: When connecting, the Ethernet cable of the UG65 device side should be installed first, otherwise, PoE devices or gateway may be damaged.

3.3 Antenna Installation
For the external antenna version, rotate the antenna into the antenna connector accordingly.
The external antenna should be installed vertically always on a site with a good signal.

Note: Please do not let the front panel of products faces to walls if using embedded LoRa antennas.

3.4 Gateway Installation
UG65 can be mounted to a wall or a pole. Before you start, make sure that your SIM card has been inserted, your antennas have been attached and all cables have been installed.

3.4.1 Wall Mounting
Preparation: mounting bracket, bracket fixing screws, wall plugs, wall mounting screws, and other, required tools.

  1. Align the mounting bracket horizontally to the desired position on the wall, use a marker pen to mark four mounting holes on the wall, and then remove the mounting bracket from the wall.
    Note: The connecting lines of adjacent points are at right angles.

  2. Drill four holes with a depth of 32 mm by using your drill with a 6 mm drill bit on the positions you marked previously on the wall.

  3. Insert four wall plugs into the holes respectively.

  4. Mount the mounting bracket horizontally to the wall by fixing the wall mounting screws into the wall plugs.

  5. Screw the bracket fixing screws to the back panel of the device, then hang the device to the mounting bracket on the wall.

3.4.2 Pole Mounting
Preparation: mounting bracket, bracket fixing screws, hose clamp and other required tools.

  1. Loosen the hose clamp by turning the locking mechanism counter-clockwise.

  2. Straighten out the hose clamp and slide it through the rectangular rings in the mounting bracket, Mwrap the hose clamp around the pole.

  3. Use a screwdriver to tighten the locking mechanism by turning it clockwise.
    Milesight UG65 Semi Industrial LoRaWAN Gateway - Pole
Mounting

  4. Screw the bracket fixing screws to the back panel of the device, then hang the device to the mounting bracket on the pole.

Milesight UG65 Semi Industrial LoRaWAN Gateway - bracket
fixing

4. Log in the Web GUI of Gateway

UG65 provides a web-based configuration interface for management. If this is the first time you configure The gateway, please use the default settings below:
ETH IP Address: 192.168.23.150
Wi-Fi IP Address: 192.168.1.1
Wi-Fi AP: Gateway_**
Username: admin
Password: password

4.1 Wireless Access
A. Enable Wireless Network Connection on your computer and search for access point “Gateway_**” to connect it.
B. Open a Web browser on your PC (Chrome is recommended) and type in the IP address 192.168.1.1 to access the web GUI.
C. Enter the username and password, click “Login”.

If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes.
D. After logging the web GUI, follow the guide to complete the basic configurations. You can also skip the instructions. It’s suggested that you change the password for the sake of security.

Milesight UG65 Semi Industrial LoRaWAN Gateway - web
GUI

E. You can view system information and perform the configuration of the gateway.

Milesight UG65 Semi Industrial LoRaWAN Gateway - e
gateway. 4.2 Wired Access
Connect PC to UG65 ETH port directly or through PoE injector. The following steps are based on Windows 10 operating system for your reference.
A. Go to “Control Panel” → “Network and Internet” → “Network and Sharing Center”, then click, “Ethernet” (May have different names).

B. Go to “Properties” → “Internet Protocol Version 4(TCP/IPv4) ”and select “Use the following IP address”, then assign a static IP manually within the same subnet of the gateway.

C. Open a Web browser on your PC (Chrome is recommended) and type in the IP address 192.168.23.1 50 to access the web GUI.
D. Enter the username and password, click “Login”.

If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes.
E. After logging the web GUI, follow the guide to complete the basic configurations. You can also skip the instructions. It’s suggested that you change the password for the sake of security.

Milesight UG65 Semi Industrial LoRaWAN Gateway -
password

F. After the guide is complete, you can view system information and perform the configuration of the gateway.

Milesight UG65 Semi Industrial LoRaWAN Gateway -
gateway

 5. Network Configuration

This section explains how to connect the gateway to the network via WAN connection, Wi-Fi or cellular.

5.1 Ethernet WAN Configuration
A. Go to the “Network”→ “Interface” → “Port” page to select the connection type and configure Ethernet port information.
B. Click “Save & Apply” for changes to take effect.

Milesight UG65 Semi Industrial LoRaWAN Gateway -WAN
Configuration

C. Connect Ethernet port of gateway to devices like router or modem.
D. Log in to the web GUI via the newly assigned IP address and go to “Status”→ “Network” to check Ethernet port status.

Milesight UG65 Semi Industrial LoRaWAN Gateway - WAN
Configuration

5.2 Wi-Fi Connection Configuration

A. Go to “Network” → “Interface” → “WLAN” and select “Client” mode.
B. Click “Scan” to search for Wi-Fi access points. Select the available one and click “Join Network”.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Wi-Fi Connection
Configuration

D. Go to “Status”→” WLAN” to check Wi-Fi status. If it shows “Connected”, it means gateway connects to Wi-Fi successfully.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Wi-Fi
successfully.

5.3 Cellular Connection Configuration

A. Go to the “Network” → “Interface” → “Cellular” → “Cellular Setting” page to enable cellular settings.
B. Choose relevant network type and fill in SIM card information like APN or PIN code.
C. Click “Save” and “Apply” for changes to take effect.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Connection
Configuration

D. Go to the “Status” → “Cellular” page to view the status of the cellular connection. If it shows “Connected”, it means the SIM has dialed up successfully. On the other hand, you can check the status of LTE indicator. If it keeps on blue light statically, it means SIM has dialed up successfully.

Milesight UG65 Semi Industrial LoRaWAN Gateway -
Cellular

6. Packet Forwarder Configuration

UG65 has embedded multiple packet forwarders like Semtech and Chirpstack Generic MQTT broker. This section explains how to connect the gateway to third-party network servers.
Make sure the gateway connects to the network as shown in Section 5.

A. Go to the “Packet Forwarder” → “General” page and click to add a network server.

Milesight UG65 Semi Industrial LoRaWAN Gateway - “Packet
Forwarder

B. Fill in the server information and enable this server.

Milesight UG65 Semi Industrial LoRaWAN Gateway - server
information

C. Go to the “Packet Forwarder” → “Radio” page to configure antenna type, center frequency and channels. The channels of the gateway and network server need to be the same.

Milesight UG65 Semi Industrial LoRaWAN Gateway - network
server

Milesight UG65 Semi Industrial LoRaWAN Gateway - Radio

D. Add the gateway on network server page. Take TTN for example, type and save the gateway EUI and other information when you connect it via Semtech packet forwarder. After you add the gateway, TTN will show connection status.

Milesight UG65 Semi Industrial LoRaWAN Gateway - FIG 2

7. Network Server Configuration

UG65 can work as a network server and transmit data to Milesight IoT Cloud or another platform via MQTT/HTTP/HTTPS.
Make sure the gateway connects to the network as shown in Section 5.

7.1 Connect UG65 to Milesight IoT Cloud
A. Go to the “Packet Forwarder” → “General” page to enable the “Milesight” type server.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Connect UG65
t

B. Go to the “Packet Forwarder” → “Radio” page to select the antenna type, center frequency and channels. The channels of the gateway and nodes need to be the same.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Device” page and click
“

C. Go to the “Network Server” → “General” page to enable the network server and “Milesight IoT Cloud” mode.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Network
Server

D. Log in the Milesight IoT Cloud. Then go to “My Devices” page and click “+New Devices” to add gateway to Milesight IoT Cloud via SN. Gateway will be added under the “Gateways” menu.

Milesight UG65 Semi Industrial LoRaWAN Gateway - FIGB
3

7.2 Connect UG65 to MQTT/HTTP Server

A. Go to the “Packet Forwarder” → “General” page to enable the “Milesight” type server.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Milesight IoT
Cloud

B. Go to the “Packet Forwarder” → “Radio” page to select the antenna type, center frequency and channels. The channels of the gateway and nodes need to be the same.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Packet
Forwarder

C. Go to the “Network Server” → “General” page to enable the network server mode.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Network
Serve

D. Go to “Network Server”→” Application” to add a new application.

Milesight UG65 Semi Industrial LoRaWAN Gateway -
Application

After saving the application, you can select HTTP, HTTPS or MQTT protocol and fill in corresponding server information to send data to another server.

E. Go to the “Profiles” page to add a new profile for the device.

Milesight UG65 Semi Industrial LoRaWAN Gateway - FIG 6

F. Go to the “Device” page and click “Add” to add LoRaWAN®node devices.

Milesight UG65 Semi Industrial LoRaWAN Gateway - Device” page and click
“

You can also click “Bulk Import” if you want to add many nodes all at once.

Milesight UG65 Semi Industrial LoRaWAN Gateway - FIG 7

Click “Template Download” to download the template file and add device information to this file. Application and device profile should be the same as you created on web page.

Milesight UG65 Semi Industrial LoRaWAN Gateway - FIG 8

F. Go to the “Packets” page to check the packets from LoRaWAN®node devices. The type starts from “Up”means uplinks and “Dn” means downlinks.

Milesight UG65 Semi Industrial LoRaWAN Gateway - FIG 9

Click “Details” to check the properties and payload contents of packets.

[END]