global sources K1183964938 Portable Cryolipolysis Machine
Notice:
- Please install the handle and filter first.
- And start to add water
How to add water for the machine?
- Please make sure that the machine is powered off.
- Put the infuse to the AFFUSION HOLE (the blue circle in as Picture 1. Please notice that you should press the blue circle and then put in the infuse. After adding water, please also press this blue circle and then pull out.)
- After inserting the infuse, please turn on the VENT HOLE button and then start to add water. (The adding water should be distilled water or pure water)
- When water comes out from the VENT HOLE, please turn off this button and dry the machine case with paper tower. Then connect power to the machine and you can use it.
Safety Notice
- Please don’t disassemble the equipment or try to do some other operation, which haven’t been indicated in our instruction. All the repairing work should be done by our admitted professional personnel
- Please don’t assemble or operate this equipment while you are near the water or your hands are wet. Notice that don’t pour the liquid on it.
- Please pull out the plug from the socket when you met such conditions as below. And in touch with professional maintenance Station.
- The equipment touched liquid
- The equipment has abnormal smell, smoking or loud and strong noise.
- Cable is broken
- The equipment is fallen down and broken
- Please don’t put anything on the cables, don’t place the equipment at any place where someone can step on the cable.
- Please pull out the power cable after using it for your safety
- Don’t put anything into the equipment’s jack, otherwise it may cause fire or touch the electricity. If something enters the equipment, please don’t pick it out by yourself, contract distributor or our company immediately
- Please don’t put the equipment on the anything that can’t stand steadily, avoid it turns over and damage.
- Our company has the right to modify the information in this introduction before notify! And keep the explanations right for the above.
Operation Notice
Before operation, please read the following content.
-
It is essential to make different setting according to specific treatment demand.
-
The application of The machine must never be painful and cause redness to the skin or leave marks.
-
Move the treatment heads slowly over the skin of the body or the face.Don’t letting
them stop in any one place on the skin. -
Do not apply the device on children less than 7 years old. The treatment to children over 7 requires medical advice.
-
Do not use this device if suffering from a fever, inflammation, dermatitis (acne, eczema, herpes), warts, open or recently stitched wounds, serious and progressive illnesses (cancer, AIDS, hepatitis, blood diseases, etc. or blood coagulation problems. Do not apply the device if you have or have had phlebitis, after veins surgery within the last two months, if you have varicose veins or tingling in your limbs, if you have any concerns consult a physician.
-
Never use the device on a pregnant woman.
-
The machine could be used on all external and healthy areas of the body except the eyes, throat, ears, glottis and the genital area.
-
Must not be applied inside the mouth, or on mucous membrane, or on nipples, or moles without medical advice.
-
Never use the device if you suffer from epilepsy. The device must not be used by any person suffering from mental illness.
-
In the case of long-term treatment with drugs such as anti-inflammation, anticoagulants, antibiotics or if your skin bruises at the slightest shock, ask advice of your doctor/physician before using.
Preparation Before Use5
- Check machine warning label details,and all tag on machine.
- Install the attached on-hook on the machine, put the probes into the corresponding racks.
- It is required to open the injection and overflow behind for adding distilled water or purified water.
- Connect the attached water funnel to the inlet, start adding purified water until water flows out from the overflow, and then close the inlet and overflow.
- Check the host power cable is connected.
- Check the key switch of machine is connected.
Operation steps
- Put the machine stability, do not connect to any probes and power supply.
- Filled with pure water,until the water come out from the vent hole (use the water pipe/funnel/filler,add 4L pure water)
- Connecting the cryolipolysis handle.Check whether connected right or not, clean or disinfect the accessory.
- After enter cryolipolysis operation interface.If the water cycle is normal,the machine enter work.if the water cycle is not normal,There will be a sound alarm,at the same time there will be a red“Error”on operation interface,in this case.must turn off the switch immediately,to check if the water is full and connecting the cryolipolysis handle again. After confirm the cryolipolysis handle enter normal working, place the other accessories well.(make sure the accessories are connect closely, and the machine can working normal), clean or disinfect the accessories
- lean the skin first, then smear the products onto the treated skin, please use anti-freeze when work with cryolipolysis handle.
- ccording the client’s fat part status, adjust the Intensity and the Vacuum mode and Working time.
- urn on the Cryolipolysis system. Working on the body. At the same time, you can adjust the intensity of the system by the button on the handle piece.
- fter treatment, please pause the working, then switch off the power. Clean the spare parts and place them in original.
System selection interface Cryolipolysis+Vacuum System
A. Please analyzer the fat part status, then adjust the appropriate Intensity and Working time.
- Time Setting: click time then click up and down,10-30mins,according to the customers need.
- Intensity Setting: click cool then click up and down,
Handle setting
Please start treatment from a higer temperature till you find the most comfortable temperature for you. We advice -5°C at Max when if the machine operating temperature (indoor temperature) is 25°C.
Cryolipolysis Treatment settings
- 15-30 minutes for each part. Freezing intensity setting to -10(from start) -12(5 mins later) -15(10 mins later) (depending on thickness of fat and health status,After 25-30 minutes of treatment, press the pause button to suspend the suction, check and add antifreeze fluid.)
- Can only treat cellulite part by part, for example, to eliminate cellulite of the entire waist, you need to complete several courses.
- Take a another cooling procedure at the same position 1 or 2 months after the first course, which can reduce the extra fat layer thickness, twice treatment, can enhance the effect of cryolipolysis, but not recommended to accept treatment repeatedly at random.
- Cryolipolysis cool-sculpturing treatment is designed for those physically healthy people who have local fat deposits, but not suitable for the one with overall obesity. It can target at the fat at a specific part, such as waist, abdomen, back, etc. The treatment is not a panacea, it can not treat obesity. It is not a substitute for liposuction or other invasive treatments. Substantial weight loss should be achieved through a balanced diet and regular exercise, cryolipolysis cool-sculpturing treatment can only eliminate the extra fat.
- Use appropriate and constant suction intensity, the suction intensity is adjustable according to the patient’s individual vulnerability. At the same time, the mode of suction and massage can be used.
- Qualified antifreeze fluid is necessary to avoid frostbite during the treatment process when the temperature is reduced to 0 to -40 degrees. (Consumables, purchased by the user)
- After the treatment, skin injury, minor frostbite, or pigment may occur, pay attention to take good care of it.
How to enter chin handle control page?
Machine Display
Taboos(who are not suitable to use this machine?)
- Pregnant women or women during in menses.
- Epileptic
- Patients with malignancy.
- atient whose wound after operation has not healed up.
- cute inflammation or epidemical patients.
- hom with heart diseases or with heart pacemaker..
- hom with kidney (gall-stone ) disease.
- ho was embedded metal object or silica gel.
- ho in menses, birth control period, emiction incontinence period, or accepting the belly operation.
- Whose body always take much inner hot.
- Who has the genetic hypersensitivity.
TECHNICAL PARAMETER
- Voltage: AC110V/220V 50-60Hz
- Power: 400w
- Temperature: -1 °C~-15°C
- Pressure output: 0-900Kpa
- Handle working size : 18*10cm, 14×5.5cm(optional), 8x4cm(optional) Screen: 8 inch touch screen
- Gross weight: 17KG