Yolanda CS10A Professional Body Composition Analyzer User Manual
- June 6, 2024
- Yolanda
Table of Contents
Professional Body Composition Analyzer CS10A
User’s Manual
CS10A User’s Manual
Precautions
- People with blow medical devices should not use this device Implantable medical electronic devices such as cardiac pacemakers Artificial heart and other medical electronic equipment Wearable medical electronic equipment such as electrocardiograph
- Do not jump on the device
- Please measure at the same time and under the same conditions every day
- To ensure accurate measurement, please place the scale on a hard and flat floor
- When there is a big deviation in measuring the weight, you can try to use a small object such as a needle to insert the mechanical reset hole
Appearance
Product Specifications
Model | CS10A |
---|---|
Dimension | Scale: 320 x 300 x 21 mm Handle: 317 x 35 x 23 mm |
Weight Range | 0.2-180kg(0.41b-3961b) |
Display type | LED |
Outputs(LED screen) | Weight, Body Fat%, BMI, Muscle(Skeletal Muscle Mass) |
Power supply | 400mAh lithium battery |
Working current | <300mA |
Data transmission | Bluetooth and WiFi |
Testing Method | Direct Segmental Multi-frequency BIA Method |
Electrode Method | Tetrapolar 8-Point Tactile Electrode Methods |
Accessories | CS10A scale, Measuring handle Type-C charging cable, User’s |
manual
Installation /Charging
Insert handle cable into the type-c port at the top of the scale
The first use requires charging or inserting the reset hole to activate the
device When the scale displays “Lo”, it means that the scale battery is low
and needs to be charged. As shown in the picture below, please use the USB
cable and the charging head(daily mobile phone charging head 5A/1A is
available) to charge
Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the condition that this device does not cause harmful interference (1) this
device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements. The
device can be used in portable exposure conditions without restriction.
FCC ID: 2ANDX-CS10A
App Usage
Download the APP
Search and download “Feelfit” in the App Store or Google play
Pairing and measurement Open Feelfit, turn on Bluetooth ( above Android
6.0 system requests to enable location access), click “+” and select the ”
Device Management”
Step on the scale with bare and dry feet
Tap the device name on the pairing page
Keep standing on the scale and holding the handle for 10-15seconds. When your
metrics appear on the APP, congratulations! you have successfully completed
the measurement Now, you can check the metrics and depth measurement report on
the app
Pair the scale with WiFi After completing the first measurement, it will
ask you whether need to pair the scale with WiFi, tap”OK “
Enter the correct WiFi password (Remark: This device only supports 2.4GHz
WiFi, so please choose a stable 2.4GHz WiFi)
Wait for connecting the scale to WiFi. At this time, the WiFi icon will flash
on the scale
Congratulation! You have successfully paired your scale to WiFi
Note:
- If you didn’t pair the scale with WiFi after the first measurement, you can select the device with the WiFi logo in “Device Management” to configure the WiFi settings
- Once you pair the scale with WiFi, you can always use WiFi to connect it without Bluetooth on
Test Posture
Stand straightly, make sure your arms are extended from your body and wear
light clothes, and don’t let your arms touch your waist
Feet Posture
Feet Posture Step on the scale barefoot. Don’t let your feet and thighs
touch each other
**Feet heels should not touch each other or make feet turn in
The feet should not touch each other
Hands Posture
** Put your thumbs on the oval electrodes and the four fingers on the strip
electrodes and hold them. Let the handle cable is facing down
Please do not hold it in a fist
The handle cable should not face up
Display icon description
| The charging icon will light up when charging
---|---
Wi-Fi icon will light up when WiFi connected
The Bluetooth icon will light up when Bluetooth connected
Muscle mass icon
BMI icon
Body fat% icon
Low power reminder
Overload reminder
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>