SIGLENT SP3050A Passive Probe Instruction Manual
- June 9, 2024
- SIGLENT
Table of Contents
SIGLENT SP3050A Passive Probe
Add: Bldg No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an
District, Shenzhen, 518101, China
Tel: +86 755 3688 7876
Fax: +86 755 3359 1582
E-mail: sales@siglent.com
SP3150A/SP3050A Instruction Manual
R 2022 SIGLENT Technologies Co., Ltd. All rights reserved.
Inform on in this publition supersedes all earlier versions. Specifictions are
subject to change without notice.
Warranty
NOTE: THE WARRANTY BELOW REPLACES ALL OTHER WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY,
FITNESS, OR ADEQUACY FOR ANY PARTICULAR PURPOSE OR USE. SIGLENT SHALL NOT BE
LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN
CONTRACT OR OTHERWISE.
Siglent warrants this oscilloscope accessory for normal use and operation
within specification for a period of one year from the date of shipment. Spare
parts, replacement parts and repairs are warranted for 90 days.
In exercising its warranty, Siglent, at its option, will either repair or
replace any assembly returned within the warranty period to the Customer
Service Department of an authorized service center. However, this will be done
only if the product is determined by Siglent’s examination to be defective
because of workmanship or materials, and the defect is not caused by misuse,
neglect, accident, abnormal conditions of operation; or, damaged by attempted
repair or modifications by a non‐authorized service facility.
This warranty replaces all other warranties, expressed or implied, including,
but not limited to, any implied warranty of merchantability, fitness, or
adequacy for any particular purposes or use. Siglent shall not be liable for
any special, incidental, or consequential damages, whether in contract or
otherwise.
Terms and Symbols
The following terms appear in this manual:
CAUTION of potential damage to equipment, or WARNING of potential for
bodily injury. Attend to the accompanying information to protect against
personal injury or damage. Do not proceed until conditions are fully
understood and met.
The following symbols may appear on the product:
- DANGER High Voltage, risk of electric shock or burn.
- ATTENTION Refer to Manual
- DOUBLE INSULATION
- PROTECTIVE (EARTH) TERMINAL
Introduction
The Siglent SP3150A/SP3050A is a passive high impedance voltage oscilloscope Probe designed and calibrated for use with general purpose oscilloscope having an input impedance of 1 MΩ and can be compensated for use with instruments having an input capacitance between 10 to 20 pF. They are compatible with oscilloscopes that automatically detect probe atenuation and adjust their readout accordingly.
Specifications
Model
| ****
Atn.
| Input Imped.| ****
B/W
| Rise Time| ****
Length
| Compensation Range
---|---|---|---|---|---|---
R(MΩ)
| ****
C(pF)
| ****
(MHz)
| ****
(ns)
| ****
(m)
| ****
(pF)
SP3150A/ SP3050A| 10x| 10| 10| 500| 0.7| 1.3| 10 – 20
-
Atenuation
-
Max. Input Voltage
Circuits not directly connected to Mains: 500 Vrms,
1500 V transient overvoltage
Measurement Category II: 400 Vrms -
Ratio …………………10:1 ± 1%
-
Pollution Degree ………………….Pollution Degree 2 (as defined in EN 61010-031)
-
Operating Altitude ………………..UP to 3000 meters
-
Max. Operating Temp ……………0° C to +50° C
-
Humidity ……………………………..5% to 95% RH (10° C to 30° C)
5% to 75% RH (30° C to 40° C)
5% to 50% RH (above 40° C)
RH not controlled below 10° C
Definitions
Measurement Category- classificafion of testing and measuring circuits
according to the types of mains circuits to which they are intended to be
connected.
Measurement Category II (CAT II)- measuring circuit connected directly to
utilization points of the low-voltage mains installation.
Assemblies without a measurement category(0)-measuring circuit is not directly
connected to the mains supplies.
Pollutin Degree 2: operating environment where normally only dry, non-
conductive pollution occurs. Temporary conductivity caused by condensation
must be expected.
SP3150A/SP3050A
EC Declaration of Conformity
Compliance was demonstrated to the specification as listed in the Official
Journal of the European Communities: Low Voltage Directive 2014/35/EU.
IEC/EN 61010-031:2015 Safety requirements for electrical equipment for
measurement, control and laboratory use – Part 031: Safety requirements for
handheld probe assemblies for electrical measurement and test.
General Safety Information
Observe generally accepted safety procedures in addition to those listed here
to avoid personal injury or damage to equipment. The overall safety of any
system incorporating this accessory is the responsibility of the assembler of
the system.
Connect only to grounded instruments. Use only with compatible Siglent
oscilloscopes that have their BNC input connected to an earth ground. Do not
connect the probe reference lead to any point which is at a potential other
than earth ground.
Connect and disconnect properly. Connect probe to the oscilloscope before
connecting it to the test circuit. Disconnect the probe input and reference
lead from the test circuit before disconneting from the oscilloscope. Do not
connect or disconnect probes while they are connected to a voltage source.
Do not overload. Do not apply any potential to the probe leads that exceeds
the maximum rating of the probe. Always comply with the Voltage vs. Frequency
Derating Curve.
Observe all terminal ratings. Observe all markings on the oscilloscope before
connecting. Consult the oscilloscope product manual for further rangs
information.
Do not remove probe casing. Touching exposed connections may result in
electric shock.
Use indoors only within operational environment listed. Do not use in wet or
explosive atmospheres. Keep product surfaces clean and dry. Handle with care.
Probe tps are extremely sharp and may puncture skin or cause other bodily
injury if not handled properly.
Keep fingers behind the finger guard of probe body and accessories.
Do not operate with suspected failures. Before each use, inspect the probe and
accessories for any potential damage such as tears or other defects in the
probe body, cable jacket, accessories, etc. If any part is damaged, cease
operation immediately and sequester the probe from inadvertent use.
Cleaning
- Clean only the exterior of the probe, cables, and accessories. Use a soft cotton cloth moistened with a mild detergent and water solution. Do not allow any portion of the probe to be submerged at any time.
- Dry the probe and accessory thoroughly before afte mpting to make any voltage measurement.
- Do not subject the probe to solvents or solvent fumes as these can cause deterioration of the probe body, cables, and accessories.
Disposal
The probe is marked with this symbol to indicate that it complies with the
applicable European Union requirements to Directives 2012/19/EU and 2013/56/EU
on Waste Electrical and Electronic Equipment (WEEE) and Batteries.
This electronic product is subject to disposal and recycling regulaons that
vary by country and region. Many countries prohibit the disposal of waste
electronic equipment in standard waste receptacles.
Probe Compensation
Proper compensation of the probe is required to assure amplitude accuracy of the waveform being measured by matching the probe to the oscilloscope’s input capacitance. Compensation should be adjusted whenever the probe is connected to or transferred between oscilloscopes.
Low Frequency
- Apply a 1 kHz square wave to the probe or connect to the oscilloscope’s calibrator output.
- Adjust the trimmer located on the SP3150A/SP3050A BNC Compensation Box until you achieve a flat-topped square wave like the center
illustration in the second figure below.
Over-compensated, correct, and under-compensated waveforms
SP3150A/SP3050A Input Impedance Profile
China RoHS Compliance
Part Name
| Toxic or Hazardous Substances and Elements
---|---
Lead (Pb)
| Mercury (Hg)| ****
Cadmium (Cd)
| Hexavalent Chromium (Cr6+)| ****
Polybrominated Biphenyls (PBB)
| ****
Polybrominated Diphenyl Ethers (PBDE)
PCBAs| X| O| O| O| O| O
Mechanical Hardware| X| O| O| O| O| O
Sheet Metal| O| O| O| O| O| O
c Parts| O| O| O| O| O| O
Protec ve Case| O| O| O| O| O| O
Cable Assemblies| X| O| O| O| O| O
Probe Tips| X| O| O| O| O| O
O : Indicates that this toxic or hazardous substance contained in all of
the homogeneous materials for this part is below the limit requirement
specified in SJ/T11363-2006.
X : Indicates that this toxic or hazardous substance contained in at
least one of the homogenous materials used for this part is above the limit
requirement specified in SJ/T11363-2006.
EFUP (Environmental Friendly Use Period): 30 Years. Use Condi ons: refer to the environmental condi ons stated in the Specific ons sec on of this Manual.
EU RoHS Compliance
The probe and its accessories conform to the 2011/65/EU RoHS2 Directive, as
they have been classified as Industrial Monitoring and Control Equipment (per
Article 3, Paragraph 24) and are exempt from RoHS compliance until 22 July
2019 (per Article 4, Paragraph 3).
The probe and its accessories also conform to the Commission Delegation
Directive (EU) 2015/863.
Replaceable Parts
Item | De | Qu y |
---|---|---|
1 | Sprung Hook, 5 mm, Black | 1 |
2 | GND Lead w/Alligator Clip | 1 |
3 | BNC Adapter, 5 mm | 1 |
4 | Replacement Tip, Black | 1 |
5 | Deluxe Trimmer Tool | 1 |
6 | IC Tip Insulator, 5 mm, Black | 1 |
7 | Probe Tip Cover | 1 |
8 | Tip Insulator, 5 mm, Black | 1 |
9 | r Rings | 1 |
10 | Probe Tip GND | 1 |
Contact Siglent
Siglent Office
If you need any technical support or other help, you can contact SIGLENT
service department directly.
Siglent Technologies Co., Ltd
Add: 3/F, Bldg No.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an
District, Shenzhen, 518101, China.
Tel: 400-878-0807
E-mail:support@siglent.com
To get latest product and service information please log in
http://www.siglent.com
SIGLENT Technologies Co., Ltd
Add: Bldg No.4 & No.5, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an
District, Shenzhen, 518101, China
Tel: + 86 755 3688 7876
Fax: + 86 755 3359 1582
Email: sales@siglent.com
Website: int.siglent.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>