Rami Yokota MI-3800ESR Air System Instruction Manual
- September 18, 2024
- Rami Yokota
Table of Contents
- MI-3800ESR Air System
- Product Information
- Specifications:
- Before Taking Into Use:
- Preparation:
- Air Pressure:
- Air Quality:
- Oiler Maintenance:
- Centralized Oiler:
- Can I use accessories not designed for this tool?
- What if I notice increased noise or vibration levels?
- What is the intended use of this tool?
- What happens if I don’t follow the manual or use the tool
MI-3800ESR Air System
“`html
Product Information
Specifications:
- Brand: MI-3800ESR
- Model: Air System
- Technical Standards: EN ISO 11148-6
- Pressure Range: 5.5 – 6.3 bar
- Maximum Pressure: 6.3 bar
- Recommended Oil Droplets: 3 to 6 per minute
- Maximum Hose Length: 6 to 8 meters
Product Usage Instructions
Before Taking Into Use:
Read and understand the contents of the manual before
installing, operating, repairing, maintaining, or changing
accessories of the tool. Only qualified and trained operators
should handle the tool.
Preparation:
Fill some droplets of resin and acid-free oil into the air inlet
and let the tool run free for a couple of seconds before connecting
the hose.
Ensure the hose and quick coupler are clean by letting air run
freely through them. Check that they have a sufficient
diameter.
Air Pressure:
Maintain air pressure at the inlet of the tool at a maximum of
6.3 bar during operation to prevent wear or damage. Power loss may
occur below 5.5 bar, and excessive low pressure can cause
additional wear/damage.
Air Quality:
Use clean, dry compressed air for optimal performance. Consider
using an air filter or a complete FRL (filter, regulator,
lubricator) unit for best results.
Oiler Maintenance:
Adjust the oiler to deliver approximately 3 to 6 droplets per
minute. Keep the air hose between the oiler and the tool within 6
to 8 meters.
Centralized Oiler:
Consider using a centralized oiler system to reduce oil
consumption by up to 80% and ensure proper lubrication.
FAQ (Frequently Asked Questions)
Can I use accessories not designed for this tool?
No, only use accessories and consumables designed for this tool
to maintain performance and safety standards.
What if I notice increased noise or vibration levels?
If you notice increased noise or vibration levels, replace the
accessories/consumables with the best available options for lower
noise and vibration levels.
What is the intended use of this tool?
This tool is designed for tightening processes on threaded
fasteners. Any other use requires a risk assessment by the
employer/user.
What happens if I don’t follow the manual or use the tool
incorrectly?
Damages resulting from not following the manual or incorrect
use/repairs are not covered by warranty. Always use the tool as
instructed in the manual.
“`
MI-3800ESR
MANUAL
EN www.rami-yokota.com
Air System
Otraap.in (3}
Main pipe downward pitc app·rox. 1 : 100 away from compressor (2).
Shut-off valve (4)
!
Main pipe (11
‘ Comp· essso (10)
t t
Filte, Regulator orner
(5)
(6)
(7)
Hose as thick a,s possible (9) —–1· Co nection
===@==w=it=h=::; tool
—–:nromi;:;:::::=i
MI-3800ESR
EN
Recommended
1. Branch pipe 2. Main pipe approx. 1:100 Downward pitch away from the
compressor 3. Drain trap 4. Shut-off valve 5. Filter 6. Regulator 7. Oiler 8.
Coupling 9. Air Hose (thick as poss) 10. Air compressor 11. Main pipe
Technical specifications
Brand Safety standard Square Drive Version Bolt capacity (mm) Impact mechanism RPM Torque (Nm) Force adjustment Airconsumption (l/s) Weight (kg) Airconnection Hosediameter (mm) Vibration level (m/s²) Sound level (dB(A)) mm A mm B Maximum Airpressure (Bar)
: Toku : EN ISO 11148-6 : 1″ : R+H : 36 : Gesloten Hamer : 4500 : 2100 : R/L 4 Pos : 15 : 9,3 : PT 1/2″ : 13 : 8,0 : 84 : 355 : 55 : 6,3
Before taking into use
Read and understand the contents of this manual before installing, operating,
repairing, maintaining, changing accessories of this tool.
Only qualified and trained operators should install, adjust or use the tool.
Please fill some droplets of resin and acid free oil into the air inlet and
let the tool run free for a couple of seconds. (E.g. Red Rooster air tool oil:
Order no. Atlub)
Before connecting the hose to the tool please check, whether the hose and the
quick coupler are clean. Do this by letting air run freely through hose and
quick coupler, It is absolutely necessary, that quick coupler and hose have a
sufficient diameter. Please note, that the hose is never too big, but mostly
too small!
Air pressure at the inlet of the tool during running has to be at the maximum
of 6.3 bar. When this pressure is exceeded, unnecessary wear and/or damage
will occur. At the pressure of below 5.5 bar power loss will occur and if the
pressure is excessively low, also additional wear/damage will occur.
The quality of the compressed air must be good, which means clean, dry and
this is best assured by means of an air filter. We advise the use of a
complete FRL (filter, regulator, lubricator) unit. The oiler has to be
adjusted to approx. 3 to 6 droplets per minute. The air hose between oiler and
tool should never exceed a length of 6 to 8 meters.
In those cases, where it is possible, use of a centralized oiler is
recommended by us. This system will allow use of less oil and assure a perfect
lubrication. When using a centralized oiler, oil consumption can be reduced by
up to 80%.
If you intend not to use the tool for a longer period of time, it has to be
oiled. Please fill some droplets of resin and acid free oil into the air inlet
and let the tool run free for a couple of seconds.
Do not ignore safety precautions!
Safety
Do not modify this tool in any way, this can cause danger for the operator.
Make sure that this manual is accessible at all times for any relevant person,
in case of loss of this manual ask your dealer for a new copy or refer to our
website. Risk of explosion or fire: Make sure that generated sparks and/or
increased temperature of the work piece can not cause any explosion or ignite
a fire. Make sure that during operation of the tool no projectiles can be
generated, this can be dangerous and may cause injuries. Make sure that the
work piece is securely fixed. Make sure that the inserted tool or accessory is
mounted correctly, if not it may cause high speed projectiles.
MI-3800ESR
Make sure that no dangerous circumstances can occur for other persons in the
work area. Always wear safety glasses during operation of the tool. The grade
of protection must be in relation to the risk of the operation. Rotating
mounted accessories can be easily entangled by rubber coated or metal
reinforced gloves. Wear suitable gloves. Keep fingers out of reach of the
inserted tool or accessory. Never hold the drive shaft, socket, bit,
inserted/mounted tool/accessory with your hands while rotating. For impact and
impulse wrenches: Only use impact sockets, see our Action catalogue. The use
of safety-/working gloves is recommended. Use ear protection as instructed by
your employer or as required by occupational health and safety requirements.
Reasonable countermeasures have to be taken to keep the noise level as low as
possible. Disconnect the air supply before changing inserted tools,
accessories, repairs or when the tool is not being used. Always check that the
mounted tool or accessory is not damaged. Breakage and flying fragments can
cause injuries. Keep rotating parts out of reach of any body part. In case of
long hair, wear a hairnet otherwise it can be trapped causing injuries. Never
wear loose clothing, wear suitable clothing otherwise it can be trapped
causing injuries. Only use accessories for this tool that are designated for
this tool by its manufacturer. Convince yourself that no persons are in the
working zone or danger zone. The advised minimum age for operating this tool
is 18 years. Keep away from whipping hoses, this can cause injuries. A broken
air hose or a hose that comes loose of the hose joint can start whipping. Shut
down the air supply immediately. In case the air hose is damaged, stop
working, shut down the air supply and replace the hose. Keep the work place
clean and organized, you may stumble and fall over a hose on the floor.
Slippery floors and objects on the floor are major causes of injuries. This
tool is not intended for use in potential expolosive hazardous areas and is
not insulated from coming into contact with electric power. In case that
during the use of this tool dust is generated by either the process or the
exhaust air blowing on dust in the environment, a risk assessment has to made.
Operator must use appropriate protection to prevent inhalation or skin
contact. According to health and safety regulations dust suction systems
should be useded if possible and be maintained according manuafacturer’s
instructions. Wear the appropriate clothing to feel comfortable at the
workplace. Cold exhaust air should be diverted from hands and body. Air under
pressure can cause injuries, be aware of this. Never direct the exhaust air to
yourself or anyone else. Do not use quick change couplings direct on the air
inlet of the tool as these may release during operation. Assemble at least 50
cm air hose with a hose joint of shock resistant material. In case universal
twist couplings ( claw couplings) are used, the lock pins must be mounted. Do
not exceed the maximum air pressure as indicated on the tool. Never carry the
tool by the air hose. On overhead work, use safety helmet. Due to the process,
the work piece, inserted/mounted tool/accessory may get hot causing burning
injuries: Be aware of this. Only use air hoses that are designed for it and
are resistant against the used air pressure. Always use “safety quick change
couplers”. Never let the tool run free in the air: the accessory may come
loose and become a projectile causing danger or injury Only use accessories
that are in good condition, worn accessories can be dangerous and cause
injuries. Only trained and qualified operators should use the tool. Never use
a damaged tool. Tools shall be inspected periodically to verify that the
ratings and markings required by the applicable part of the ISO 11148 series
are legibly marked on the tool. If not the user/employer shall obtain
replacement labels from the dealer or manufacturer. Use only tight fitting
gloves, loose gloves can be trapped or entangled causing injuries. Use the
specified gloves for the application that protects against: heat, cold,
entanglement, cutting, impacting Do not wear any shawls jewelry etc that can
be trapped or entangled causing injuries. In case of power loss, release the
trigger immediate. Take care that hands can’t be crushed between the tool and
work piece, especially when unscrewing. Make the possible countermeasures to
minimize noise emission: if possible, use silence materials on the workpiece
or walls around the work station. A risk assessment related to the noise
emission at the work station on the work piece has to be made to determine the
correct ear protection according to health and safety regulation. A risk
assessment related to the vibration exposure to determine the maximum working
hours per day for the operator. Vibration can cause damage to blood vanes and
nerves (white finger disease). Hold the tool with light but safe grip, higher
grip force can increase vibration effects. Whipping air hoses can cause
injuries. Always check if air hose is damaged and that the fittings and
couplings are not loose. Use only hardened steel hose fittings (or same
strength other fittings) for impact, impulse or vibrating tools.
Accessories
Only use accessories and consumables that are designed for the use with this
tool. Select the best available inserted/mounted accessories/consumables for
the lowest possible noise level and vibration. Replace them in case of an
increased noise level and/or vibration.
MI-3800ESR
Do not use worn or bad fitting impact sockets or extensions, as this is likely
to increase noise and vibration. Make sure that the inserted/mounted
tool/accessory is properly held by the retainer and make sure that the
retainer is in good condition. Never use the tool without a retainer as this
may cause high speed projectiles. Never cool down a hot tool/accessory as this
may influence the hardness causing dangerous circumstances. Use the
inserted/mounted accessory/tool according to the manufacturer specifications.
Only use impact rated sockets when using impact or impulse wrenches.
Using the tool:
Before start using the tool, make sure that you are familiar with the
workplace and surrounding area. Always obey the safety regulations for the
work area you are working in. Hold the tool always firmly with both hands.
During operating the tool, the operator may be exposed to hazards as crushing,
impacts, heat, vibration, cuts, abrasions, etc: Wear suitable gloves. Any
person handling the tool must be able to handle the size, weight and power of
the tool. Always be prepared for normal/abnormal movements/forces generated by
the tool. Keep your body in balance, place your feet safe and secure. In case
of interruption of the air supply, release the lever/trigger. When using a
power tool, you may experience discomfort in your hands, arms, shoulders, neck
and other parts of your body. If you experience symptoms such as persistent or
recurring discomfort, pain, throbbing, aching, tingling, numbness, burning
sensation, or stiffness: Do not ignore these warning signs. Stop using the
tool, tell your employer and consult a qualified health professional. Check if
the direction of rotation is in the required direction. Check if the power
setting (air flow) is according the required power for the application. Place
the tool with the accessory on the bolt/nut screw. Pull the trigger to start
the tool and release the trigger to stop the tool. Do not overtighten the
bolt/nut/screw, a broken part can become a projectile causing danger or
injury. When loosening the bolt/nut/screw may become a projectile causing
danger or injury. Operator should change posture regularly to avoid discomfort
and fatigue. Use hear protection according to employer, health and safety
regulations.
Maintenance:
Check the tool regularly for loose bolts/screws or parts. Measure the rpm of
the tool regularly, in case of higher or lower rpm than indicated in the
technical specifications: Stop using the tool immediate and have it repaired.
In case of power loss: Have the tool repaired. Only trained and qualified
engineers are allowed to adjust or repair the tool. In case the tool is
equipped with a silencer, make sure that this silencer is working properly, a
damaged silencer has to be replaced. In case of disposal of the tool, follow
local regulations, so as much as possible can be recycled. Do not throw it in
the normal waste bin. The tool should be maintained regularly to minimize the
noise emission and occurring vibration. Disconnect the air supply during
maintenance on the tool. For impact wrenches, maintain the tool at least
yearly or after 100.000 cycles.
Intended use:
The user or the user’s employer shall assess the specific use that can be
present as a result of each use.
Never use the tool otherwise than the tool is designed for and as explained in
this manual.
Damages as a consequence of not following this manual, or caused by incorrect
use or incorrect repairs, will never be covered by our warranty and we will
have no responsibility for it. We reserve the right for technical
improvements, without prior notification. This tool is designed for tightening
processes on threaded fasteners, if used otherwise a risk assessment has to be
made by the employer/user.
Warranty
The warranty period from the date of purchase is as follows: · 12 months on
Yokota , Toku and Red Rooster tools; · 3 months on spare parts of tools, which
are repaired by us. Warranty covers material or construction mistakes of the
manufacturer, which are clearly definable. Replacement of parts or repair by
an official Yokota/Red Rooster service workshop is free of charge, when the
tool is covered by warranty. Freight or postage is for the account of the
buyer. Damage attributable to a normal wear, overloading or incorrect use is
excluded from warranty. Always consult this manual! Replacement of tools as a
consequence of warranty claims is no part of the warranty arrangements. Also
claims for loss of production and/or other damages are excluded from this
warranty. Repairs under warranty can only be considered, when the tool is in
its original state and it is accompanied by a copy of the purchase invoice.
Warranty claims have to be made through the dealer, who has supplied the tool
concerned.
MI-3800ESR
Declaration of Conformity
Declaration of Conformity
Brand: Toku Product: Impact Wrenches Type: MI-3800ESR Capacity: 2100
WE, RAMI YOKOTA B.V. , hereby declare that this product is conform the European Directive 2006/42/EG and, the standard EN ISO 11148-6
Technical file available from Rami Yokota BV: RAMI YOKOTA BV De Ruyterkade 120 1011 AB Amsterdam THE NETHERLANDS
Date: 09-03-2020 Signature:
Place: Amsterdam
N. Nauta Managing Director RAMI YOKOTA BV
MI-3800ESR
MI-5500ES
MANUAL
EN www.rami-yokota.com
MI-5500ESR
EN
Recommended
1. Branch pipe 2. Main pipe approx. 1:100 Downward pitch away from the
compressor 3. Drain trap 4. Shut-off valve 5. Filter 6. Regulator 7. Oiler 8.
Coupling 9. Air Hose (thick as poss) 10. Air compressor 11. Main pipe
Technical specifications
Brand Safety standard Square Drive Version Bolt capacity (mm) Impact mechanism RPM Torque (Nm) Force adjustment Airconsumption (l/s) Weight (kg) Airconnection Hosediameter (mm) Vibration level (m/s²) Sound level (dB(A)) mm A mm B Maximum Airpressure (Bar)
: Toku : EN ISO 11148-6 : 1 1/2″ : H : 52 : Dynapact : 2800 : 5500 : R/L 4 Pos : 15,0 : 18,1 : PT 1/2″ : 13 : 14,3 : 109 : 553 : 63 : 6,3
Before taking into use
Read and understand the contents of this manual before installing, operating,
repairing, maintaining, changing accessories of this tool.
Only qualified and trained operators should install, adjust or use the tool.
Please fill some droplets of resin and acid free oil into the air inlet and
let the tool run free for a couple of seconds. (E.g. Red Rooster air tool oil:
Order no. Atlub)
Before connecting the hose to the tool please check, whether the hose and the
quick coupler are clean. Do this by letting air run freely through hose and
quick coupler, It is absolutely necessary, that quick coupler and hose have a
sufficient diameter. Please note, that the hose is never too big, but mostly
too small!
Air pressure at the inlet of the tool during running has to be at the maximum
of 6.3 bar. When this pressure is exceeded, unnecessary wear and/or damage
will occur. At the pressure of below 5.5 bar power loss will occur and if the
pressure is excessively low, also additional wear/damage will occur.
The quality of the compressed air must be good, which means clean, dry and
this is best assured by means of an air filter. We advise the use of a
complete FRL (filter, regulator, lubricator) unit. The oiler has to be
adjusted to approx. 3 to 6 droplets per minute. The air hose between oiler and
tool should never exceed a length of 6 to 8 meters.
In those cases, where it is possible, use of a centralized oiler is
recommended by us. This system will allow use of less oil and assure a perfect
lubrication. When using a centralized oiler, oil consumption can be reduced by
up to 80%.
If you intend not to use the tool for a longer period of time, it has to be
oiled. Please fill some droplets of resin and acid free oil into the air inlet
and let the tool run free for a couple of seconds.
Do not ignore safety precautions!
Safety
Do not modify this tool in any way, this can cause danger for the operator.
Make sure that this manual is accessible at all times for any relevant person, in case of loss of this manual ask your dealer for a new copy or refer to our website.
Risk of explosion or fire: Make sure that generated sparks and/or increased temperature of the work piece can not cause any explosion or ignite a fire.
Make sure that during operation of the tool no projectiles can be generated, this can be dangerous and may cause injuries.
Make sure that the work piece is securely fixed.
Make sure that the inserted tool or accessory is mounted correctly, if not it may cause high speed projectiles.
MI-5500ESR
Make sure that no dangerous circumstances can occur for other persons in the work area. Always wear safety glasses during operation of the tool. The grade of protection must be in relation to the risk of the operation. Rotating mounted accessories can be easily entangled by rubber coated or metal reinforced gloves. Wear suitable gloves. Keep fingers out of reach of the inserted tool or accessory. Never hold the drive shaft, socket, bit, inserted/mounted tool/accessory with your hands while rotating. For impact and impulse wrenches: Only use impact sockets, see our Action catalogue. The use of safety-/working gloves is recommended. Use ear protection as instructed by your employer or as required by occupational health and safety requirements. Reasonable countermeasures have to be taken to keep the noise level as low as possible. Disconnect the air supply before changing inserted tools, accessories, repairs or when the tool is not being used. Always check that the mounted tool or accessory is not damaged. Breakage and flying fragments can cause injuries. Keep rotating parts out of reach of any body part. In case of long hair, wear a hairnet otherwise it can be trapped causing injuries. Never wear loose clothing, wear suitable clothing otherwise it can be trapped causing injuries. Only use accessories for this tool that are designated for this tool by its manufacturer. Convince yourself that no persons are in the working zone or danger zone. The advised minimum age for operating this tool is 18 years. Keep away from whipping hoses, this can cause injuries. A broken air hose or a hose that comes loose of the hose joint can start whipping. Shut down the air supply immediately. In case the air hose is damaged, stop working, shut down the air supply and replace the hose. Keep the work place clean and organized, you may stumble and fall over a hose on the floor. Slippery floors and objects on the floor are major causes of injuries. This tool is not intended for use in potential expolosive hazardous areas and is not insulated from coming into contact with electric power. In case that during the use of this tool dust is generated by either the process or the exhaust air blowing on dust in the environment, a risk assessment has to made. Operator must use appropriate protection to prevent inhalation or skin contact. According to health and safety regulations dust suction systems should be useded if possible and be maintained according manuafacturer’s instructions. Wear the appropriate clothing to feel comfortable at the workplace. Cold exhaust air should be diverted from hands and body. Air under pressure can cause injuries, be aware of this. Never direct the exhaust air to yourself or anyone else. Do not use quick change couplings direct on the air inlet of the tool as these may release during operation. Assemble at least 50 cm air hose with a hose joint of shock resistant material. In case universal twist couplings ( claw couplings) are used, the lock pins must be mounted. Do not exceed the maximum air pressure as indicated on the tool. Never carry the tool by the air hose. On overhead work, use safety helmet. Due to the process, the work piece, inserted/mounted tool/accessory may get hot causing burning injuries: Be aware of this. Only use air hoses that are designed for it and are resistant against the used air pressure. Always use “safety quick change couplers”. Never let the tool run free in the air: the accessory may come loose and become a projectile causing danger or injury Only use accessories that are in good condition, worn accessories can be dangerous and cause injuries. Only trained and qualified operators should use the tool. Never use a damaged tool. Tools shall be inspected periodically to verify that the ratings and markings required by the applicable part of the ISO 11148 series are legibly marked on the tool. If not the user/employer shall obtain replacement labels from the dealer or manufacturer. Use only tight fitting gloves, loose gloves can be trapped or entangled causing injuries. Use the specified gloves for the application that protects against: heat, cold, entanglement, cutting, impacting Do not wear any shawls jewelry etc that can be trapped or entangled causing injuries. In case of power loss, release the trigger immediate. Take care that hands can’t be crushed between the tool and work piece, especially when unscrewing. Make the possible countermeasures to minimize noise emission: if possible, use silence materials on the workpiece or walls around the work station. A risk assessment related to the noise emission at the work station on the work piece has to be made to determine the correct ear protection according to health and safety regulation. A risk assessment related to the vibration exposure to determine the maximum working hours per day for the operator. Vibration can cause damage to blood vanes and nerves (white finger disease). Hold the tool with light but safe grip, higher grip force can increase vibration effects. Whipping air hoses can cause injuries. Always check if air hose is damaged and that the fittings and couplings are not loose. Use only hardened steel hose fittings (or same strength other fittings) for impact, impulse or vibrating tools.
Accessories
Only use accessories and consumables that are designed for the use with this tool.
Select the best available inserted/mounted accessories/consumables for the lowest possible noise level and vibration. Replace them in
case of an increased noise level and/or vibration.
MI-5500ESR
Do not use worn or bad fitting impact sockets or extensions, as this is likely
to increase noise and vibration. Make sure that the inserted/mounted
tool/accessory is properly held by the retainer and make sure that the
retainer is in good condition. Never use the tool without a retainer as this
may cause high speed projectiles. Never cool down a hot tool/accessory as this
may influence the hardness causing dangerous circumstances. Use the
inserted/mounted accessory/tool according to the manufacturer specifications.
Only use impact rated sockets when using impact or impulse wrenches.
Using the tool:
Before start using the tool, make sure that you are familiar with the
workplace and surrounding area. Always obey the safety regulations for the
work area you are working in. Hold the tool always firmly with both hands.
During operating the tool, the operator may be exposed to hazards as crushing,
impacts, heat, vibration, cuts, abrasions, etc: Wear suitable gloves. Any
person handling the tool must be able to handle the size, weight and power of
the tool. Always be prepared for normal/abnormal movements/forces generated by
the tool. Keep your body in balance, place your feet safe and secure. In case
of interruption of the air supply, release the lever/trigger. When using a
power tool, you may experience discomfort in your hands, arms, shoulders, neck
and other parts of your body. If you experience symptoms such as persistent or
recurring discomfort, pain, throbbing, aching, tingling, numbness, burning
sensation, or stiffness: Do not ignore these warning signs. Stop using the
tool, tell your employer and consult a qualified health professional. Check if
the direction of rotation is in the required direction. Check if the power
setting (air flow) is according the required power for the application. Place
the tool with the accessory on the bolt/nut screw. Pull the trigger to start
the tool and release the trigger to stop the tool. Do not overtighten the
bolt/nut/screw, a broken part can become a projectile causing danger or
injury. When loosening the bolt/nut/screw may become a projectile causing
danger or injury. Operator should change posture regularly to avoid discomfort
and fatigue. Use hear protection according to employer, health and safety
regulations.
Maintenance:
Check the tool regularly for loose bolts/screws or parts. Measure the rpm of
the tool regularly, in case of higher or lower rpm than indicated in the
technical specifications: Stop using the tool immediate and have it repaired.
In case of power loss: Have the tool repaired. Only trained and qualified
engineers are allowed to adjust or repair the tool. In case the tool is
equipped with a silencer, make sure that this silencer is working properly, a
damaged silencer has to be replaced. In case of disposal of the tool, follow
local regulations, so as much as possible can be recycled. Do not throw it in
the normal waste bin. The tool should be maintained regularly to minimize the
noise emission and occurring vibration. Disconnect the air supply during
maintenance on the tool. For impact wrenches, maintain the tool at least
yearly or after 100.000 cycles.
Intended use:
The user or the user’s employer shall assess the specific use that can be
present as a result of each use.
Never use the tool otherwise than the tool is designed for and as explained in
this manual.
Damages as a consequence of not following this manual, or caused by incorrect
use or incorrect repairs, will never be covered by our warranty and we will
have no responsibility for it. We reserve the right for technical
improvements, without prior notification. This tool is designed for tightening
processes on threaded fasteners, if used otherwise a risk assessment has to be
made by the employer/user.
Warranty
The warranty period from the date of purchase is as follows: · 12 months on
Yokota , Toku and Red Rooster tools; · 3 months on spare parts of tools, which
are repaired by us. Warranty covers material or construction mistakes of the
manufacturer, which are clearly definable. Replacement of parts or repair by
an official Yokota/Red Rooster service workshop is free of charge, when the
tool is covered by warranty. Freight or postage is for the account of the
buyer. Damage attributable to a normal wear, overloading or incorrect use is
excluded from warranty. Always consult this manual! Replacement of tools as a
consequence of warranty claims is no part of the warranty arrangements. Also
claims for loss of production and/or other damages are excluded from this
warranty. Repairs under warranty can only be considered, when the tool is in
its original state and it is accompanied by a copy of the purchase invoice.
Warranty claims have to be made through the dealer, who has supplied the tool
concerned.
MI-5500ESR
Declaration of Conformity
Declaration of Conformity
Brand: Toku Product: Impact Wrenches Type: MI-5500ES Capacity: 5500
WE, RAMI YOKOTA B.V. , hereby declare that this product is conform the European Directive 2006/42/EG and, the standard EN ISO 11148-6
Technical file available from Rami Yokota BV: RAMI YOKOTA BV De Ruyterkade 120 1011 AB Amsterdam THE NETHERLANDS
Date: 09-03-2020 Signature:
Place: Amsterdam
N. Nauta Managing Director RAMI YOKOTA BV
MI-5500ESR
www.rami-yokota.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>