Hisense R32 Air Conditioner Instruction Manual

June 6, 2024
Hisense

Thank you very much for purchasing this Air Conditioner. Please read these use and installation instructions carefully before installing and using this appliance and keep this manual for future reference.

Safety instructions

  1. To guarantee the unit work normally, please read the manual carefully before installation, and try to install strictly according to this manual.
  2. Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner.
  3. Properly ground the air conditioner into the earth.
  4. Check the connecting cables and pipes carefully, make sure they are correct and firm before connecting the power of the air conditioner.
  5. There must be an air-break switch.
  6. After installing, the consumer must operate the air conditioner correctly according to this manual, keep suitable storage for maintenance and moving of the air conditioner in the future.
  7. The fuse of indoor unit: T 3.15A 250VAC or T 5A 250VAC. Please refer to the screen printing on the circuit board for the actual parameters, which must be consistent with the parameters on the screen printing.
  8. For 7k~12k models, the fuse of outdoor unit: T 15A 250VAC or T 20A 250VAC. Please refer to the screen printing on the circuit board for the actual parameters, which must be consistent with the parameters on the screen printing.
  9. For 18k models, the fuse of outdoor unit: T 20A 250VAC.
  10. For 24k models, the fuse of outdoor unit: T 30A 250VAC.
  11. The installation instructions for appliances that are intended to be permanently connected to fixed wiring, and have a leakage current that may exceed 10 mA, shall state that the installation of a residual current device (RCD) having a rated residual operating current not exceeding 30 mA is advisable.
  12. Warning: Risk of electric shock can cause injury or death: Disconnect all remote electric power supplies before servicing.
  13. The maximum length of the connecting pipe between the indoor unit and outdoor unit should be less than 5 meters. It will affect the efficiency of the air conditioner if the distance is longer than that length.
  14. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  15. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  16. The batteries in the remote controller must be recycled or disposed of properly. Disposal of Scrap Batteries — Please discard the battery’s assorted municipal waste at the accessible collection point.
  17. If the appliance is fixed wiring, the appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III conditions, and these means must be incorporated in the fixed wiring in accordance with the wiring rules.
  18. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
  19. The appliance shall be installed in accordance with national wiring regulations.
  20. The air conditioner must be installed by professional or qualified persons.
  21. The appliance shall not be installed in the laundry.
  22. Regarding installation, please refer to the section “Installation instructions”.
  23. Regarding to maintenance, please refer to section “Maintenance”.
  24. For models using R32 refrigerant, the piping connection should be conducted on the outdoor side.

Preparation before use

Note

  • For the multi-system, the refrigerant refers to the multi outdoor unit.

  • When charging refrigerant into the system, make sure to charge in a liquid state,if the refrigerant of the appliance is R32. Otherwise, the chemical composition of refrigerant (R32) inside the system may change and thus affect the performance of the air conditioner.

  • According to the character of the refrigerant (R32, the value of GWP is 675), the pressure of the tube is very high, so be sure to be careful when you install and repair the appliance.

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.

  • Installation of this product must be done by experienced service technicians professional installers only in accordance with this manual.

  • The temperature of the refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
    Preset
    Before using the air conditioner, be sure to check and preset the following.

  • Remote Control presetting Each time the remote control is replaced with new batteries or is energized, the remote control auto presetting heat pump. If the air conditioner you purchased is a Cooling Only one, a heat pump remote controller can also be used.

  • The back-light function of Remote Control(optional) Hold down any button on the remote control to activate the backlight. It automatically shuts off 10 seconds later.
    Note: Back-light is an optional function.

  • Auto Restart Presetting The air conditioner has an Auto-Restart function.

Safeguarding the environment
This appliance is made of recyclable or reusable material. Scrapping must be carried out in compliance with local waste disposal regulations. Before scrapping it, make sure to cut off the main cord so that the appliance cannot be re-used. For more detailed information on handling and recycling this product, contact your local authorities who deal with the separate collection of rubbish or the shop where you bought the appliance.
SCRAPPING OF APPLIANCE
This appliance is marked according to the European Directive 2012/19/EC, Waste Electrical and Electronic Equipment (WEEE). This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

Safety precautions

Symbols in this Use and Care Manual are interpreted as shown below.

Be sure not to do.
Grounding is essential.
Pay attention to such a situation.
Warning: Incorrect handling could cause a serious hazard, such as death, serious injury, etc.
Use correct power supply in accordance with the rating plate requirement. Otherwise, serious faults or hazards may occur, or fire maybe breaks out.

Keep the power supply circuit breaker or plug from dirt. Connect the power supply cord to it firmly and correctly, lest an electric shock or a fire breaks out due to insufficient contact. Do not use the power supply circuit breaker or pull off the plug to turn it off during operation. This may cause a fire due to spark, etc.

It is the user’s responsibility to make the appliance be grounded according to local codes or ordinances by a licensed technician.

It is harmful to your health if the cool air reaches you for a long time. It is advisable to let the air flow be deflected to all the room.

Prevent the airflow from reaching the gas burners and stove.

Do not touch the operation buttons when your hands are wet.

Turn off the appliance by remote control firstly before cutting off the power supply if a malfunction occurs.

Never insert a stick or similar obstacle to the unit. Since the fan rotates at high speed, this may cause an injury.

Do not repair the appliance by yourself. If this is done incorrectly, it may cause an electric shock, etc.

Do not put any objects on the outdoor unit.

Do not knit, pull, or press the power supply cord, lest the power supply cord be broken. An electric shock or fire is probably caused by a broken power supply cord.

Safety precautions

Precautions for using R32 refrigerant
The basic installation work procedures are the same as the conventional refrigerant
(R22 or R410A). However, pay attention to the following points:
CAUTION

  1. Transport of equipment containing flammable refrigerants Compliance with the transport regulations

  2. Marking of equipment using signs Compliance with local regulations

  3. Disposal of equipment using flammable refrigerants Compliance with national regulations

  4. Storage of equipment/appliances The storage of equipment should be in accordance with the manufacturer’s instructions.

  5. Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.

  6. Information on servicing
    6-1 Checks to the area
    Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
    6-2 Work procedure
    •   Work shall be undertaken under a controlled procedure so as to minimise the risk of flammable gas or vapor being present while the work is being performed.
    6-3 General work area
    •  All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided.
    •  The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
    6-4 Checking for presence of refrigerant
    • The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres.
    •  Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
    6-5 Presence of fire extinguisher
    •  If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand.
    •  Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
    6-6 No ignition sources
    •  No person carrying out work in relation to a refrigeration system that involves exposing any pipework that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.
    •  All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing, and disposal, during which flammable refrigerant can possibly be released to the surrounding space.
    •  Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.
    6-7 Ventilated area
    •  Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.
    •  A degree of ventilation shall continue during the period that the work is carried out.
    •  The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
    6-8 Checks to the refrigeration equipment
    •  Where electrical components are being changed, they shall be fit for the purpose and to the correct specification.
    •  At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: ­
    – The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
    – The ventilation machinery and outlets are operating adequately and are not obstructed;
    – If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
    – Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
    – Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.
    6-9 Checks to electrical devices
    •   Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures.
    •   If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: ­ That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; ­ That there no live electrical components and wiring are exposed while charging, recovering or purging the system; ­ That there is continuity of earth bonding.

  7. Repairs to sealed components During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation. Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifications. NOTE: The use of silicone sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.

  8. Repair to intrinsically safe components Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

  9. Cabling Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.

  10. Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.

  11. Leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants: ­ Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) ­ Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. ­ Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. ­ Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. ­ If a leak is suspected, all naked flames shall be removed/ extinguished. ­ If leakage of refrigerant is found which requires brazing, all of the refrigerants shall be recovered from the system, or isolated (by means of shut-off valves) in a part of the system remote from the leak. ­ Oxygen-free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.

  12. Removal and evacuation When breaking into the refrigerant circuit to make repairs ­ or for any other purpose ­ conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to ­ Remove refrigerant; ­ Purge the circuit with inert gas; Evacuate; ­ Purge again with inert gas; ­ Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to the atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.

  13. Charging procedures In addition to conventional charging procedures, the following requirements shall be followed: ­ Ensure that contamination of different refrigerants does not occur when using charging equipment. ­ Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them. ­ Cylinders shall be kept upright. ­ Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. ­ Label the system when charging is complete (if not already). ­ Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system, it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow-up leak test shall be carried out prior to leaving the site.

  14. Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.
    a) Become familiar with the equipment and its operation.
    b) Isolate system electrically.
    c) Before attempting the procedure ensure that: ­ Mechanical handling equipment is available, if required, for handling refrigerant cylinders; ­ All personal protective equipment is available and being used correctly; ­ The recovery process is supervised at all times by a competent person; ­ Recovery equipment and cylinders conform to the appropriate standards.
    d) Pump down the refrigerant system, if possible.
    e) If a vacuum is not possible, make a manifold so that refrigerant can be
    removed from various parts of the system.
    f) Make sure that the cylinder is situated on the scales before recovery takes place.
    g) Start the recovery machine and operate in accordance with the manufacturer’s instructions.
    h) Do not overfill cylinders. (No more than 80 % volume liquid charge).
    I ) Do not exceed the maximum working pressure of the cylinder, even temporarily.
    j ) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
    k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.

  15. Labelling Equipment shall be labeled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

  16. Recovery

  • When removing refrigerants from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
  • When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed.
  • Ensure that the correct number of cylinders for holding the total system charge is available.
  • All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders for the recovery of refrigerant).
  • Cylinders shall be complete with pressure relief valve and associated shutoff valves in good working order.
  • Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
  • The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants.
  • In addition, a set of calibrated weighing scales shall be available and in good working order.
  • Hoses shall be complete with leak-free disconnect couplings and in good condition.
  • Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained, and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release.
  • Consult the manufacturer if in doubt.
  • The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
  • If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant.
  • The evacuation process shall be carried out prior to returning the compressor to the suppliers.
  • Only electric heating to the compressor body shall be employed to accelerate this process.
  • When oil is drained from a system, it shall be carried out safely.
  • When moving or relocating the air conditioner, consult experienced service technicians for disconnection and reinstallation of the unit.
  • Do not place any other electrical products or household belongings under the indoor unit or outdoor unit.
  • Condensation dripping from the unit might get them wet, and may cause damage or malfunction of your property.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operating ignition sources(for example, open flames, an operating gas appliance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that refrigerants may not contain an odor.
  • To keep ventilation openings clear of obstruction.
  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  • The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
  • Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry-recognized assessment specification.
  • Servicing shall only be performed as recommended by the equipment manufacturer.
  • Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be installed, operated, and stored in a room with a floor area larger than 10 m2.
  • The installation of pipe-work shall be kept to a room with a floor area larger than 10 m2. The pipe-work shall be in compliance with national gas regulations.
  • The maximum refrigerant charge amount is 2.5 kg.
  • The specific refrigerant charge is based on the nameplate of the outdoor unit.
  • Mechanical connectors used indoors shall comply with ISO 14903.
  • When mechanical connectors are reused indoors, sealing parts shall be renewed.
  • When flared joints are reused indoors, the flare part shall be re-fabricated.
  • The installation of pipe-work shall be kept to a minimum.
  • Mechanical connections shall be accessible for maintenance purposes.

Explanation of symbols displayed on the indoor unit or outdoor unit.

Caution. dill of fire| WARNING| This symbol shows that this appliance uses a flammable refrigerant.
If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire
---|---|---
| CAUTION| This symbol shows that the operation manual should be read carefully.
| CAUTION| This symbol shows that service personnel should be handling this equipment with reference to the installation manual.
| CAUTION| This symbol shows that information is available such as the operating manual or installation manual.

Installation instructions

Installation diagram

The above figure is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased.
Installation must be performed in accordance with the national wiring standards by authorized personnel only.
Select the installation locations
Location for Installing Outdoor Unit

  • Where it is convenient to install and well ventilated.
  • Avoid installing it where flammable gas could leak.
  • Keep the required distance apart from the wall.
  • The pipe length between indoor and outdoor units should be no more than 5 meters in factory default status, but it can go up to maximum 20 meters with an additional refrigerant charge.
  • Keep the outdoor unit away from greasy dirt, vulcanization gas exit.
  • Avoid installing it by the roadside where there is a risk of muddy water.
  • A fixed base where it is not subject to increased operation noise.
  • Where there is not any blockage of the air outlet.
  • Avoid installing under direct sunlight, in an aisle or sideway, or near heat sources and ventilation fans.
  • Keep away from flammable materials, thick oil fog, and wet or uneven places.

Model| Max. allowed pipe length without additional refrigerant (m)| Limit of pipe length (m)| Limit of Elevation Difference H (m)| Required amount of additional refrigerant (g/m)
---|---|---|---|---
7K-12K| 5| 15| 8| 20
18K| 5| 20| 15| 20
21K-25K| 5| 20| 15| 30

If the height or pipe length is out of the scope of the table, please consult the merchant.

Connecting of the Cable

Note: For some models, it is necessary to remove the cabinet to connect to the indoor unit terminal.
Outdoor Unit

  1. Remove the access door from the unit by loosening the screw. Connect the wires to the terminals on the control board individually as follows.
  2. Secure the power cord onto the control board with a cable clamp.
  3. Reinstall the access door to the original position with the screw.
  4. Use a recognized circuit breaker for 24K model between the power source and the unit. A disconnecting device to adequately disconnect all supply lines must be fitted.

The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected.

Caution:

  1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, refer to the circuit diagram posted on the inside of the access door.
  2. Confirm that the cable thickness is as specified in the power source specification
  3. Check the wires and make sure that they are all tightly fastened after the cable connection.
  4. Be sure to install an earth leakage circuit breaker in wet or moist areas.

Cable Specifications

Capacity (Btu/h) Power cord Power connecting cord
  Type Normal cross
– sectional area Type Normal cross

– sectional area
7K,9K,12K| HO7RN-F| 1.0mm2X3| HO7RN-F| 1.0mm2X5
18K| HO7RN-F| 1.5mm2X3| HO7RN-F| 1.5mm2X5
24K| HO7RN-F| 2.5mm2X3| HO7RN-F| 2.5mm2X5

Attention:
The plug must be accessible even after the installation of the appliance in case there is a need to disconnect it. If not possible, connect the appliance to a double-pole switching device with a contact separation of at least 3 mm placed in an accessible position even after installation.

Wiring diagram
Make sure that the color of the wires in the outdoor unit and terminal No. are the same as those of the indoor unit.
7K~24K Model

Warning: Before obtaining access to terminals,all supply circuits must be disconnected.

Outdoor unit installation

  1. Install Drain Port and Drain Hose (for heat-pump model only)
    The condensate drains from the outdoor unit when the unit operates in heating mode. In order not to disturb your neighbor and protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer to the chassis of the outdoor unit, then connect a drain hose to the port as the right figure demonstrates.

  2. Install and Fix Outdoor Unit
    Fix with bolts and nuts tightly on a flat and strong floor. If installed on the wall or roof, make sure to fix the supporter well to prevent it from shaking due to serious vibration or strong wind.

  3. Outdoor Unit Piping Connection
    Remove the valve caps from the 2-way and 3-way valves.
    Connect the pipes to the 2-way and 3-way valves separately according to the required torque.

  4. Outdoor Unit Cable Connection (see the previous page)

Air purging
The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor. After connecting the indoor and outdoor units, release air and moisture from the refrigerant cycle using a vacuum pump, as shown below.
Note: To protect the environment, be sure not to discharge the refrigerant to the air directly. See next page for air purging steps.

How to Purge Air Tubes :

  1. Unscrew and remove caps from 2 and 3-way valves.
  2. Unscrew and remove the cap from the service valve.
  3. Connect vacuum pump flexible hose to the service valve.
  4. Start vacuum pump for 10-15 minutes until reaching a vacuum of 10 mm Hg absolutes.
  5. With the vacuum pump still running close the low-pressure knob on the vacuum pump manifold. Then stop the vacuum pump.
  6. Open the 2-way valve,1/4 turn, then close it after 10 seconds. Check the tightness of all joints using liquid soap or an electronic leak detector.
  7. Turn 2 and 3-way valves stem to fully open the valves. Disconnect the flexible vacuum pump hose.
  8. Replace and tighten all valve caps.

FAQS

Does the Hisense R32 air conditioner come with an installation kit?

Yes, the Hisense R32 Air Conditioner normally comes with the installation kit, which includes mounting brackets and the required hardware, for standard installations.

Is there a self-cleaning feature on the Hisense R32 air conditioner?

A self-cleaning feature may be available on some Hisense R32 Air Conditioner models, which helps to improve air quality by removing mold and dust from the evaporator coils.

How long is the Hisense R32 air conditioner’s warranty valid?

The Hisense R32 Air Conditioner comes with a 1 to 5 year parts and labor guarantee that varies by location and model.

Where can I locate the Hisense R32 air conditioner’s user manual?

The Hisense R32 Air Conditioner’s user manual is often packaged with the item. Additionally, you can access digital copies by contacting customer care or visiting the official Hisense website.

Is there a sleep mode on the Hisense R32 air conditioner?

Yes, the Hisense R32 Air Conditioner’s majority of models have a sleep mode option that modifies the temperature and fan speed to promote a good night’s sleep.

Is the Hisense R32 air conditioner’s air filter washable or replaceable?

The Hisense R32 Air Conditioner’s air filter is normally washable and reusable, however it’s important to consult the user manual for the particular model for details.

Can you use the Hisense R32 Air Conditioner for both heating and cooling purposes?

Yes, many Hisense R32 Air Conditioner models are heat pumps that can do both cooling and heating duties.

Which refrigerant is utilized by the Hisense R32 Air Conditioner?

The Hisense R32 Air Conditioner, as its name suggests, employs R32 refrigerant, which is renowned for having a lesser global warming potential than more traditional refrigerants like R410A.

Has a remote control been included with the Hisense R32 air conditioner?

Yes, remote control is included in the majority of models of the Hisense R32 Air Conditioner for ease of use.

What is the Hisense R32 air conditioner’s energy efficiency rating?

The EER, or energy efficiency rating, is dependent on the particular model. Hisense R32 air conditioners often have a high EER, which qualifies them as energy-saving appliances.

How much cooling power does the Hisense R32 air conditioner have?

Depending on the model, the Hisense R32 Air Conditioner’s cooling capability can range from 8,000 to 24,000 BTUs (British Thermal Units).

Is there a dehumidification setting on the Hisense R32 air conditioner?

The Hisense R32 Air Conditioner does, in fact, frequently have a dehumidification setting that aids in removing extra moisture from the air without considerably reducing room cooling.

What area of cooling can the Hisense R32 Air Conditioner handle at its highest capacity?

The maximum cooling area is determined by the model’s cooling capability. As already noted, it covers a variety of room sizes with a BTU range of 8,000 to 24,000.

Can a smartphone app be used to operate the Hisense R32 air conditioner?

A specialized smartphone app may be used to control some advanced models of the Hisense R32 Air Conditioner, which may have smart features.

What safeguards is the Hisense R32 Air Conditioner equipped with?

A built-in thermostat to avoid overheating, auto-shutoff during malfunctions, and a fire-resistant electrical enclosure are typical safety features that may differ between models.

Hisense R32 Air Conditioner Instruction Manual.pptx

Hisense R32 Air Conditioner-VIDEO

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hisense User Manuals

Related Manuals