perixx PM-720 Wireless Bluetooth Ergonomic Vertical Trackball Mouse User Manual
- June 5, 2024
- Perixx
Table of Contents
PM 720 Wireless Bluetooth Ergonomic Vertical Trackball Mouse
User Manual
Product Illustration
How do connect PERIMICE-720?
If the Bluetooth pairing fails, please remove PERIMICE-720 from the list of paired devices and redo it from Step-1.
Trackball Cleaning Instructions
FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Caution
- The manufacturer and re-resellers are not responsible for any technical malfunctions, damage, or personal injury incurred by:
- Any attempt to dismantle, change or modify the product in any manner
- Malfunction or damage is due to misuse or improper alteration or repair
- Malfunction or damage caused by external influence such as falling
- Malfunction or damage is caused by fire, salt, gas, earthquake, lightning, wind, water, or other natural calamities, or abnormal voltage.
- Malfunction or damage is caused by other devices connected to the products
- Malfunction or damage is caused by high temperature, humid, greasy, dusty, and hazardous environment
- You are cautioned that changes or modifications not expressly approved by Perixx Computer GmbH could void your authority to operate the equipment
- All brand names, trademarks, and logos are the properties of their respective owners. Please Note: Long-term repetitive use of any keyboard and mouse could cause injury to the user. Perixx recommends users avoid excessive use of this or any keyboard and mouse.
Important Safety Instructions:
- Avoid dropping
- Do not disassemble.
- This product is suitable for moderate climates only.
- The maximum ambient temperature during use of this product must not exceed 40 degree
- Open flame sources, such as candles, must not be placed on this product
- Only use a dry cloth or brush to clean this product.
Perixx offers a one-year limited warranty with an optional one-year extension.
Specification
Interface 2.4GHz/BT4.1
Size 13910250mm
Weight 140±5g
Input current 3V/15mA
Battery required AAA batteries 2pcs
Material ABS
Operating system Win 7 or later
requirements| Number of buttons 8
DPI 600(L)/1600(H)
Acceleration 10G
Tracking speed 30IPS
Report rate 125Hz
Durability 3 million keypresses
---|---
PERIMICE-720
Equipment name Type designation (Type)
Unit| Restricted substances and its chemical symbols
Lead
(Pb)| Mercury
(Hg)| Cadmium
(Cd)| Hexavalent
chromium
CrI-6| Polybrominated biphenyls
(PBB)| Polybrominated diphenyl ethers
(PBDE)
| 0| 0| 0| 0| 0| 0
| 0| 0| 0| 0| 0| 0
| 0| 0| 0| 0| 0| 0
USB| 0| 0| 0| 0| 0| 0
| 0| 0| 0| 0| 0| 0
| 0| 0| 0| 0| 0| 0
Note 1 : “Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicates that the
percentage content of the restricted substance exceeds the reference
percentage value of the present condition.
Note 2 : “0” indicates that the percentage content of the restricted substance
does not exceed the percentage of the reference value of presence.
Note 3: The ” – ” indicates that the restricted substance corresponds to the
exemption