Midea DLFSDA Ducted Style Ductless System Owner’s Manual

June 6, 2024
Midea

Midea DLFSDA Ducted Style Ductless System

NOTE TO EQUIPMENT OWNER:

Please read this Owner’s Information Manual carefully before installing and using this appliance and keep this manual for future reference. For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.

UNIT INFORMATION

Model #
Serial # ____

INSTALLATION INFORMATION
Date Installed

DEALERSHIP CONTACT INFORMATION

Company Name: __
Address:_____

Phone Number:____
Technician Name:__

A NOTE ABOUT SAFETY

Any time you see this symbol in manuals, instructions and on the unit, be aware of the potential for personal injury. There are 3 levels of precaution:

  1. DANGER identifies the most serious hazards which will result in severe personal injury or death.
  2. WARNING signifies hazards that could result in personal injury or death.
  3. CAUTION is used to identify unsafe practices which could result in minor personal injury or product and property damage.

NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

WARNING

PERSONAL INJURY, DEATH AND / OR PROPERTY DAMAGE HAZARD Failure to follow this warning could result in personal injury, death or property damage. Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or service agency must use factory−authorized kits or accessories when modifying this product. Read and follow all instructions and warnings, including labels shipped with or attached to unit before operating your new air conditioner.

GENERAL

The ducted fan coil unit provides quiet, maximum comfort. In addition to cooling and/or heating, the ducted fan coil unit matched with an outdoor condensing unit filters and dehumidifies the air in the room to provide maximum comfort.

IMPORTANT:

The ducted fan coil unit should be installed by authorized personnel only; using approved tubing and accessories. If technical assistance, service or repair is needed, contact the installer. The ducted fan coil unit can be set up and operated from the remote control (provided). If the remote is misplaced, the system can be operated from the “Auto” setting on the unit.

Operating Modes

The ducted fan coil unit has five operating modes:

  • FAN Only
  • AUTO
  • HEATING (heat pumps only)
  • COOLING
  • DEHUMIDIFICATION (DRY)

FAN Only
In the FAN Only mode, the system filters and circulates the room air without changing room air temperature.

AUTO
In the AUTO mode, the system automatically cools or heats the room according to the user-selected set point.
NOTE: AUTO mode is recommended for use on single zone applications ONLY. Using AUTO CHANGEOVER on multi-zone applications could set an indoor unit to STANDBY mode, indicated with two dashes (–) on the display, which will turn off the indoor unit until all the indoor units are in the same mode (COOLING or HEATING). HEATING is the system’s priority mode. Simultaneous HEATING and COOLING is not allowed.

HEATING
In the HEATING mode, the system heats and filters the room air.

COOLING
In the COOLING mode, the system cools, dries and filters the room air.

DEHUMIDIFICATION (DRY)
In DEHUMIDIFICATION mode, the system dries, filters and
slightly cools the room air temperature. This mode prioritizes air dehumidification but it does not take the place of a
dehumidifier.

Wireless Remote Control
The remote control transmits commands to set up and operate the system. The control has a window display panel that displays the current system status. The control can be secured to a surface when used with the mounting bracket provided.

Wired Remote Control (Optional)
Refer to the Wired Controller manual.

PART LIST

Midea DLFSDA Ducted Style Ductless System fig 1

Part Name

Indoor Unit
Drain Adapter
Air Filter
Wired Controller
Wireless Remote

DISPLAY PANELS (SHIPPED INSIDE THE CONTROL BOX)

WIRELESS REMOTE CONTROL FUNCTION BUTTONS

Before you begin using your new air conditioner, familiarize yourself with the remote control.

Midea DLFSDA Ducted Style Ductless System fig 3

NOTE : New remote controller starting on production of week 10 year 2021 (serial number V210240000). For advanced functions, refer to the RG10B(B1)/BGEFU1 Wireless Remote Controller’s Service Manual.

WIRELESS REMOTE CONTROL LCD SCREEN INDICATORS

Midea DLFSDA Ducted Style Ductless System fig 4

REMOTE CONTROL

CAUTION

EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage. Handle the control with care and avoid getting the control wet.

IMPORTANT:

The wireless remote control can operate the unit from a distance of up to 26 ft. (8 m) as long as there are no obstructions.

NOTE : If a Wireless Remote controller is used, relocate the IR (Infrared) Receiver within line of sight of the remote location using the 6 ft. cable included. The factory location of the IR receiver is inside the control box.
When the timer function is used, the remote control should be kept in the vicinity of the unit (within 26 ft. (8 m). The remote control can perform the following basic functions:

  • Turn the system ON and OFF
  • Select the operating mode
  • Adjust room air temperature set point and fan speed

Refer to the “WIRELESS REMOTE CONTROL FUNCTION BUTTONS” on page 4 for a detailed description of all the capabilities of the remote control.

Battery Installation

Two AAA 1.5v alkaline batteries (included) are required to operate the remote control.
To install or replace batteries:

  1. Slide the back cover off the control to open the battery compartment.
  2. Insert the batteries. Follow the polarity markings inside the battery compartment.
  3. Replace the battery compartment cover.

Remote Control Operation – Quick Start

NOTE: When transmitting a command from the remote control to the unit, be sure to point the control toward the right side of the unit. The unit confirms receipt of a command by sounding an audible beep.

  1. Turn the unit on by pushing ON/OFF.
    NOTE: If there is a preference for °C rather than °F (default), press and hold TEMP or TEMP together for approximately 3 seconds.

  2. Select the desired mode by pushing MODE.

  3. Select the temperature set point by pointing the control toward the unit and pressing the increase/decrease temperature set point buttons until the desired temperature appears on screen.

  4. Press FAN to select the desired fan speed.
    NOTE: If the unit is operating in DRY or AUTO mode, the fan speed will be automatically set.

  5. 5. Set the airflow direction. When the unit is turned on, the Up-Down airflow louvers default to the cooling or heating position. The user can adjust the horizontal Up-Down airflow louver position by pushing DIRECT or have continuous louver movement by pressing SWING.

Manual Operation

If the remote control is lost, damaged, or the batteries are exhausted, MANUAL can be used to run the unit. When MANUAL is pressed once, the AUTO mode takes affect (heat or cool). When this button is pressed twice, the system enters the TEST mode and runs for 30 minutes in the COOLING mode (it will run in the AUTO mode afterward). When pressed three times, the system turns OFF.

The set conditions of manual operation are as follows:

  • Preset set point: 76°F (24°C)
  • Fan speed: AUTO

BASIC REMOTE CONTROL OPERATION

Before the operation, ensure the unit is plugged in and power is available.

COOL mode

  1. Press MODE to select the COOL mode.
  2. Set your desired temperature using TEMP  or TEMP 
  3. Press FAN to select the fan speed in a range of AU‘100%,
  4. Press ON/OFF to start the unit.

Setting Temperature

The operating temperature range for units is 60-86°F (16-30°C)/(68-82 °F (20-28°C) (depends on model). You can increase or decrease the set temperature in 1°F (0.5°C) increments.

HEAT Mode

  1. Press MODE to select the HEAT mode.
  2. Set your desired temperature using TEMP  or TEMP .
  3. Press FAN to select the fan speed in the range of AU-100%.

NOTE : As the outdoor temperature drops, the performance of your unit’s HEAT function may be affected. In such instances, we recommend using this air conditioner in conjunction with other heating appliances.

AUTO Mode

In AUTO mode, the unit automatically selects the COOL, FAN, or HEAT operation based on the set temperature.

  1. Press MODE to select AUTO.
  2. Set your desired temperature using TEMP or TEMP
  3. Press ON/OFF to start the unit.

NOTE : FAN Speed can not be set in the AUTO mode.

DRY Mode

  1. Press MODE to select the DRY mode.
  2. Set your desired temperature using TEMP  or TEMP 
  3. Press ON/OFF to start the unit.

FAN Mode

  1. Press MODE to select the FAN mode.
  2. Press FAN to select the fan speed in the range of AU-100%.
  3. Press ON/OFF to start the unit.

CAUTION

EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage. Handle the controller with care and avoid getting it wet.

REMOTE CONTROL FUNCTIONS

Pressing ON/OFF

When the air conditioner is not in operation, the remote control displays the last setpoint and mode.

  • Press ON/OFF to start the unit.
    • The unit starts in the last operating mode and set point. The ON/OFF indicator appears.
  • Press ON/OFF to stop the unit.
    • All the indicator lights on the unit go out, and the remote control displays the set point and mode.

NOTE: If ON/OFF is pressed too soon after a stop, the compressor will not start for 3 to 4 minutes due to the inherent protection against frequent compressor cycling. The unit only emits an audible beep when the signals are received correctly.

Selecting an Operating Mode

Use OPERATING MODE to select one of the available modes.

Setting the Room Temperature Set Point

Press TEMP or TEMP to raise or lower the temperature. The unit confirms the signal receipt with a beep and the value of the set temperature appears on the display and changes accordingly. The temperature can be set between 62F (17C) and 86F (30C) in increments of 1°F or 1°C. NOTE: In the COOLING mode, if the temperature selected is higher than the room temperature, the unit will not start. The same applies for the HEATING mode if the selected temperature is lower than the room temperature.

Press FAN to select the fan speed.

NOTE : When the unit is on, the fan runs continuously in cooling or heating. When in heating, there might be situations where the fan will slow down or shut off to prevent cold blow.

Direct

NOTE: The DIRECT feature is not available on this model.

Swing

NOTE: The SWING feature is not available on this model.

Timer Function

TIMER ON (to start the unit) and TIMER OFF (to stop the unit) can be used separately or together.

Timer ON Only

This function allows the unit to start automatically at the set time. The TIMER ON function can be set while the unit is on or off.

Unit On

  1. Press TIMER ON to initiate the auto-on time sequence. The set time is displayed in the remote control display. Every time TIMER ON is pressed, the time increases by 30 minutes, up to 10h. It increases by 60 minutes, afterward, until the time setting reaches 24h.
  2. When the TIMER ON is set, the TIMER light on unit illuminates. The unit continues to run at the set time.

Unit Off

  1. Set the timer described in the UNIT ON section. The unit starts at the set time.
  2. Adjust the TIMER ON settings to 0.0 to cancel this option.

Timer OFF Only

This function allows the unit to stop automatically at the set time. The timer can be set while the unit is on or while it is off.

Unit On

Press TIMER OFF to initiate the auto-off time sequence. The set time appears on the remote control display. Every time TIMER OFF is pressed, the time increases by 30 minutes, up to 10h. It increases by 60 minutes, afterwards, until the time settings reach 24h. When the TIMER OFF is set, the timer light on the unit illuminates and the unit turns off automatically at the set time.

Unit Off

  1. Set the TIMER OFF as described in the UNIT ON section. The TIMER display on the unit illuminates and the unit remains off.
  2. Adjust the TIMER ON settings to 0.0 to cancel this option.

Timer ON and Timer OFF

Use both functions to program the unit to turn on and shut off at specified times.

Unit Off

  1. Set TIMER ON as previously described.
  2. Set TIMER OFF as previously described. The unit starts automatically at the set TIME ON and turns off at the set TIME OFF.

Unit On

  1. Set TIME OFF as previously described.
  2. Set TIME ON as previously described. The unit turns off automatically at the set TIME OFF and turns on at the set TIME ON.

SLEEP Mode

SLEEP mode is used to conserve energy and can be used when the unit is in the COOL, HEAT or AUTO mode only.

COOLING Mode

Push SLEEP. After 1 hour the set point raises by 1.8°F (1°C). After another hour, the set point raises by another 1.8°F (1°C) and the fan runs in a low speed. The unit shuts off 5 hours after setting the SLEEP mode. SLEEP mode cancels if either MODE, TEMP, FAN, TIMER, or ON/OFF on the remote control is pressed.

HEATING Mode

Same as the COOLING mode however the set points are lowered by 1.8°F (1°C).

TURBO Mode

Use TURBO to cool or heat the room rapidly.

  1. Press TURBO. An audible “beep” is heard if the indoor unit supports this function. The fan runs on super high speed. The TURBO mode terminates automatically 20 minutes after selecting TURBO.
  2. To cancel TURBO, select TURBO mode again. When the TURBO mode terminates, the unit reverts to the original setting.

Clean Mode (Available only on sizes 18 to 24)

Press CLEAN to activate or deactivate the self−cleaning function. Under this function, the air conditioner automatically cleans and dries the evaporator. The cleaning cycle takes 16 minutes, after which the unit turns off automatically. Pressing CLEAN in the middle of the cycle cancels the operation and turns off the unit. This function can be activated only in the COOL or DRY mode.

SILENCE Mode

NOTE: The SILENCE Mode (SLC) is not available on this model.

LED Light

Press the LED to turn the display light on and off.

Resetting the Remote Control

If the batteries in the remote control are removed, the current settings will be canceled and the control returns to the initial settings and will be in standby mode. Push ON/OFF to activate.

Time Delay

If ON/OFF is pressed too soon after a stop, the compressor will not start for 3 to 4 minutes due to the inherent protection against frequent compressor cycling. The unit only emits an audible beep when the signals are received correctly.

Heating Features

If the unit is in heating mode, there is a delay when the fan starts. The fan starts only after the coil is warmed up to prevent cold blow.

Auto Defrost Operation

In HEATING mode, if the outdoor coil is frosted, the indoor fan and outdoor fan turns off while the system removes the frost from the outdoor coil. The system automatically reverts to normal operation when frost is removed from the outdoor unit.

Auto Start

If the power fails while the unit is operating, the unit stores the operating condition, and the unit will start operation automatically under those conditions when the power is restored.

CLEANING, MAINTENANCE, AND TROUBLESHOOTING

CAUTION

ELECTRICAL SHOCK HAZARD

Failure to follow this caution may result in personal injury or death. Always turn off power to the system before performing any cleaning or maintenance to the system. Turn off the outdoor disconnect switch located near outdoor unit. Be sure to disconnect the indoor unit if on a separate switch.

EQUIPMENT DAMAGE/OPERATION HAZARD

Failure to follow this caution may result in equipment damage or improper unit operation. Operating the system with dirty air filters may damage the indoor unit and could cause reduced cooling performance, intermittent system operation, frost build-up on indoor coil or blown fuses.

Periodic Maintenance

Periodic maintenance is recommended to ensure proper operation of the unit. Recommended maintenance intervals may vary depending on the installation environment, e.g., dusty zones, etc. Refer to Table 2 on page 11.

CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury. The coil fins are very sharp. Use caution when cleaning. Always wear safety protection.

Cleaning the Coil

Clean the coil at the beginning of each cooling season, or when necessary. Use a vacuum cleaner or a long-bristle brush to avoid damage to the coil fins.

Cleaning the Air Filters

Remove and clean the air filters once a month. A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. NOTE : If air filters show signs of excessive wear or are torn, they must be replaced. Contact your local dealer for replacement filters.

  1. Unscrew filters from the frame.

  2. Pull filters down to remove.

  3. Vacuum the filters.

  4. Clean with warm water.

  5. Shake filter to remove excess water and dry thoroughly.

  6. Replace filter by sliding into rack until filter snaps in place.

  7. The close front panel on the unit.

CAUTION

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment damage. When cleaning the front panel, do not use water hotter than 105°F (40.6°C) and do not pour water onto the fan coil. Do not use abrasive or petroleum based cleaners as they may damage the front panel.

Preparing for Extended Shutdown Period

Clean the filters and reposition them in the unit. Operate the unit in FAN ONLY mode for 12 hours to dry all internal parts. Turn the main power supply off and remove batteries from the remote control.
System Operation Recommendations

The items outlined in the following list help to assure proper system operation:

  • Replace both remote control batteries at the same time.
  • Point the remote control toward the unit display panel when transmitting a command.
  • Keep doors and windows closed while unit is operating.
  • Contact an authorized service representative if a problem arises that cannot be easily resolved.
  • Do not perform cleaning or maintenance activities while the unit is on.
  • Keep the display panel on the unit away from direct sunlight and heat as this may interfere with remote control transmissions.
  • Do not block air intakes and outlets on the indoor or outdoor units.

Energy Saving Recommendations

The following recommendations will add greater efficiency to the ductless system:

  • Select a comfortable thermostat setting and leave it at chosen setting. Avoid continually raising and lowering the setting.
  • Keep the filter clean. Frequent cleaning may be necessary depending on indoor air quality.
  • Use drapes, curtains or shades to keep direct sunlight from heating the room on very hot days.
  • Limit the unit’s run time by using the TIMER function.
  • Do not obstruct the air intake on the front panel.

TROUBLESHOOTING

Refer to Table 4 on page 12 before contacting your local dealer.

INDOOR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR
Clean Air Filter* ·
Change Remote Control Batteries ·
OUTDOOR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR
Clean Outdoor Coil from Outside ·
Clean Outdoor Coil from Inside† ·
Blow Air Over Electric Parts† ·
Check Electric Connection Tightening† ·
Clean Fan Wheel† ·
Check Fan Tightening† ·
Clean Drain Pans† ·

Increase the frequency in dusty zones. Maintenance to be carried out by qualified service personnel. Refer to the Installation Manual.

CAUTION

If one of the following conditions occurs, switch off the power supply immediately and contact your dealer for further assistance.

  • The operation light continues to flash rapidly after the unit has been restarted.
  • The remote control buttons do not work.
  • The unit continually trips fuses or circuit breakers.
  • A foreign object or water enters the air conditioner.
  • Other abnormal situations.

Common Problems

Problem Possible Causes

Unit does not turn on when pressing ON/ OFF

| The unit has a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.
Cooling and Heating Models: If the Operation light and PRE-DEF (Pre- heating/ Defrost) indicators are illuminated, the outdoor temperature is too cold and the unit’s anti-cold wind is activated in order to defrost the unit.
Cooling-only Models: If the FAN ONLY indicator is illuminated, the outdoor temperature is too cold and the unit’s anti-freeze protection is activated in order to defrost the unit.

The unit changes from COOL mode to FAN mode

| The unit changes its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating again.
The set temperature has been reached, at which point the unit turns off the compressor. The unit will resume operating when the temperature fluctuates again.
The indoor unit emits white mist| In humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist.
Both the indoor and outdoor units emit white mist| When the unit restarts in the HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.

The indoor unit makes noises

| A squeaking sound is heard when the system is OFF or in the COOL mode. The noise is also heard when the drain pump (optional) is in operation.
A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.

Both the indoor unit and outdoor unit make noises

| A low hissing sound may occur during operation. This is normal and is caused by refrigerant gas flowing through both the indoor and outdoor units.
A low hissing sound may be heard when the system starts, has just stopped running or is defrosting. This noise is normal and is caused by the refrigerant gas stopping or changing direction.
The outdoor unit makes noises| The unit will make different sounds based on its current operating mode.

Dust is emitted from either the indoor or outdoor unit

| The unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by covering the unit during long periods of inactivity.

The unit emits a bad odor

| The unit may absorb odors from the environment (such as furniture, cooking, cigarettes, etc.) which will be emitted during operations.
The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operate| During operation, the fan speed is controlled to optimize product operation.
PROBLEM| POSSIBLE CAUSE| SOLUTION
---|---|---




Unit/System Does Not Work

| The circuit breaker has tripped or a fuse has blown.| Reset the circuit breaker or replace the fuse with the specified replacement fuse.
Power failure| Restart the operation when the power is restored.
Diagnostic lights illuminate.*| Call your service representative
Voltage is too low.| Call your service representative.
Remote control batteries need replacing| Replace the remote control batteries.
The unit’s 3 minute protection has been activated| Wait three minutes after restarting the unit.





Poor cooling performance

| The filter is blocked by dust.| Clean the air filter
Temperature is not set properly.| Check the temperature and reset if necessary.
A window or door is open.| Close the window or door.
The outdoor unit is obstructed.| Turn the unit off, remove the obstruction and turn it back on.
The fan speed is too low.| Change the fan speed selection.
The operation mode is in Fan instead of Cool.| Change the operating mode to Cool or reset the unit.
The operation mode is in Fan instead of Cool.| Change the operating mode to Cool or reset the unit.
Low refrigerant due to leak or long-term use of refrigerant.| Check for leaks, re-seal if necessary and top off refrigerant.



Poor heating performance

| The filter is blocked with dust.| Clean the filter.
The temperature is set too low.| Check the temperature and reset if necessary.
A window or door is open| Ensure all the doors and windows are closed while operating the unit.
The outdoor unit is obstructed.| Turn the unit off, remove the obstruction and turn the unit back on.
Unit stops during operation| The OFF timer is not operating correctly.| Restart the operating mode.
Diagnostic lights illuminate| Call a service representative for service

Diagnostic lights are a combination of lights that will illuminate in the display area on the unit. They are a combination of the lights you see during normal operation.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Midea User Manuals

Related Manuals