dji T30 Intelligent Battery Station User Guide
- June 6, 2024
- DJi
Table of Contents
dji T30 Intelligent Battery Station
Disclaimer
Congratulations on purchasing your new DJITM product. Read this entire
document and all safe and lawful practices DJI provided carefully before use.
Failure to read and follow instructions and warnings may result in serious
injury to yourself or others, damage to your DJI product, or damage to other
objects in the vicinity. By using this product, you hereby signify that you
have read this document carefully and that you understand and agree to abide
by all terms and conditions of this document and all relevant documents of
this product. You agree to only use this product for purposes that are proper.
You agree that you are solely responsible for your own conduct while using
this product, and for any consequences thereof. DJI accepts no liability for
damage, injury, or any legal responsibility incurred directly or indirectly
from the use of this product.
DJI is a trademark of SZ DJI TECHNOLOGY CO., LTD. (abbreviated as “DJI”) and
its affiliated companies. Names of products, brands, etc., appearing in this
document are trademarks or registered trademarks of their respective owner
companies. This product and document are copyrighted by DJI with all rights
reserved. No part of this product or document shall be reproduced in any form
without the prior written consent or authorization of DJI.
This document and all other collateral documents are subject to change at the
sole discretion of DJI. For up to date product information, visit
http://www.dji.com and click on the product page for this product.
This document is available in various languages. In the event of divergence
among different versions, the English version shall prevail.
Warning
- The power cable of the AC input current is 16 A. Use a power outlet that can provide a current exceeding 16 A for the T10 Intelligent Battery Station and use two separate power outlets of a total current exceeding 32 A for the T30 Intelligent Battery Station. A certain power margin is required for safety.
- DO NOT connect two AC power cables simultaneously when using the T30 Intelligent Battery Station indoors.
- This product is used to charge aircraft that are used in plant protection operations. Before using such aircraft, make sure you understand and comply with the local laws and regulations and, if required, have obtained corresponding approval and clearance from the related government agencies.
- DO NOT use this product under direct sunlight, in rain, or in a damp environment.
- Keep the battery station away from heat, pressure, water, flammable gases, and corrosives.
- The battery station should be kept in an environment with a temperature range of -5° to 45° C (23° to 113° F).
- Place the battery station on a flat and stable surface. In order to prevent fire hazards, make sure the device is properly insulated and that there is sufficient space forventilation (at least 50 cm).
- In case of fire, make sure to use a dry powder fire extinguisher. A liquid fire extinguisher may lead to an electrical hazard.
- DO NOT unplug the AC cable or charging cable while the battery station is in use. Remove batteries after charging is complete.
- If there is any noticeable buildup, wipe the battery station or power ports with a clean, dry cloth.
- DO NOT use the battery station during a thunderstorm.
- Refer to the user guide of the batteries for more safety instructions before use.
- DO NOT hold the charging cables to carry the battery station. Otherwise, the cables may be damaged.
- DO NOT use the battery station in an area where batteries are stored. There should be a distance of at least 30 cm between the battery station and any charging batteries. Otherwise, the battery station or charging batteries may be damaged by excessive heating and may even lead to a fire hazard.
- Keep the battery station away from inflammable materials while charging. DO NOT place the battery station or charging batteries on a blanket or any carpeted surfaces when in use.
- For activation or firmware updates, the battery station can be connected to the DJI ASSISTANTTM 2 for MG or the remote controller of the T10, T30, or T20. Make sure the remote controller has been updated to the latest version before activating or updating the battery station.
Introduction
The T30/T10 Intelligent Battery Station can connect with up to two batteries. While charging, the battery station monitors the status of the batteries and can automatically adjust the charging current if required. The battery station continues to charge even if the ventilation holes are blocked. Users can check the battery charging status LEDs and the warning indicator on the operation panel of the battery station to confirm if there are any errors. The battery station can be connected to a remote controller using a USB-C cable and users can launch the DJI MG or DJI AGRASTM app to check more detailed information regarding any errors. Additionally, the battery station has the following functions: overcurrent protection, overcharging protection, under-voltage protection, overheating protection, and status display.
The general descriptions in this user guide apply to both the T30 Intelligent Battery Station and T10 Intelligent Battery Station. The illustrations in this user guide may vary from the actual product. The T30 Intelligent Battery Station is used as an example below.
Overview
Battery Station
- Operation Panel
- Charging Cables Clamp
- Front Panel Dustproof Cover
- Charging Cables Storage
- Handle
- Charging Cable
- USB-C Port Cover
- AC Power Port
- AC Power Dustproof Cover
- GND Port
Operation Panel
-
Charging Status LED × 2
Each LED indicates the charging status of the battery connected to a charging cable. The numbers (1-2) correspond to the position of the charging cable on the battery station. -
Warning Indicator
The warning indicator will be on if the battery station detects any abnormalities. If the indicator turns solid yellow, connect the battery station to a remote controller using a USB-C cable to confirm if there are any errors. If the indicator turns solid red, stop charging immediately. Only start to charge again once the indicator is no longer solid red -
Power Button
Press to power the battery station on and off. It is recommended to press the power button and unplug the AC power cable to power off the station.
Mounting the Battery Station
If the CPX503-3000 switching power supply has not been mounted to the battery station before leaving the factory, follow the instructions below to mount.
-
Loosen the screws and remove the front panel.
-
Insert the CPX503-3000 switching power supply into the battery station as shown below. The T30 Intelligent Battery Station has two CPX503-3000 switching power supplies while the T10 Intelligent Battery Station has one.
-
Attach the panel and secure using the screws.
Activation
The battery station requires activation before using for the first time. If the warning indicator is solid green, it means the battery station has not been activated. Follow the steps below to activate the battery station:
Method 1: Using the DJI MG App or DJI Agras App
- Connect the battery station to a power outlet.
- Connect the battery station to the remote controller using a USB-C cable.
- Press the power button to power on the battery station.
- Run the app and follow the prompts to finish activation.
Method 2: Using DJI Assistant 2 for MG
- Connect the battery station to a power outlet.
- Connect the battery station to the PC using a USB-C cable.
- Visit www.dji.com to download DJI Assistant 2 for MG. Install and run the software.
- Press the power button to power on the battery station.
- Use your DJI account to log in and click “Battery Station / Inverter Generator” and follow the prompts to finish activation.
Make sure the PC or smart device is connected to the internet during activation.
Using the Battery Station
Up to two batteries can be connected to the T30/T10 Intelligent Battery Station. Follow the instructions below to use the battery station.
-
Connect the battery station to a power outlet.
|- When using the T30 Intelligent Battery Station, each AC power cable must be connected to a separate AC power outlet or power strip with a rated current of more than 16 A.
- Only use one AC power cable when using the T30 Intelligent Battery Station indoors. This will reduce the maximum power output by half.
---|---
- Connect the battery to the battery station.
| Make sure to place the charging battery on the same side that the charging cable is fixed to the battery station.
---|--- - Make sure all cables are correctly connected and press the power button on the operation panel of the battery station. The two LEDs and the warning indicator will flash simultaneously. After powering on, the only lights remaining will be the charging status LEDs, which represent the batteries currently connected. This indicates that self-diagnosis is complete and the device is working normally. For more information about how to check if there are any errors during self-diagnosis, refer to the LEDs and Warning Indicator Description. Alternatively, connect the battery station to a remote controller and launch the DJI MG or DJI Agras app for more detailed information about the errors.
- If no errors are detected during self-diagnosis, the battery station will begin to charge the batteries. If two batteries are connected simultaneously, the battery station will charge them in order of their power level, starting from highest to lowest.
|
- Before use, make sure there are no obvious defects on the battery station or batteries (e.g., jams, breakages, or short circuits).
- DO NOT power the battery station on unless the batteries are correctly connected.
- The battery station will automatically adjust the charging current based on the condition of the batteries being charged. For example, if the battery temperature is below 15° C (59° F), the charging current will be limited and the charging time will be longer. The charging time depends on the battery model and battery temperature. The lower the battery temperature, the longer the charging time will be. The charging temperature range varies depending on the battery model. Refer to the user guide of the battery to check the charging temperature range.
---|---
LEDs and Warning Indicator Description
During charging, the status LED will blink when the corresponding charging battery is experiencing an abnormality due to the cable being disconnected, a high or low temperature, overvoltage, or overcurrent. Once charging is complete, the status LED will be solid green. The battery can be disconnected from the battery station.
Battery Station Status:
LEDs
| Warning Indicator| Power Button Indicator|
Description
---|---|---|---
/
| Solid green|
/
| The battery station is ready to be activated, or under loader stage
Solid yellow
| Solid yellow| Solid green| Self-diagnosis and power supply of the battery
station are normal
/| /| Solid green|
The battery station is ready to connect to a battery
Solid yellow| Blinks yellow twice continuously| /|
The battery station logs are being exported and it has stopped charging. Restart the battery station after the logs have been exported
Charging Indicators:
LED Blinking Pattern
| Warning Sound| Description
---|---|---
Solid yellow
| /|
The battery in the corresponding position to the number is connected and queued to charge
Blinks green| /|
The battery in the corresponding position to the number is charging
Solid green
| /| The battery in the corresponding position to the number is fully charged
Blinks yellow three times continuously| /|
The temperature of the battery in the corresponding position to the number is too low and the battery station has stopped charging
Blinks yellow four times continuously
| /|
The temperature of the battery in the corresponding position to the number is too high and the battery station has stopped charging
Blinks red once continuously
| Beeps once continuously|
The battery in the corresponding position is not correctly connected or an unauthorized battery is connected. This warning will only appear 10 seconds after the battery is connected
Blinks red twice continuously
| Beeps twice continuously| The connector short-circuited. Check the battery
or the battery station
Solid red| Beeps three times continuously|
Critical error detected
The warning indicator will light up if one of the following problems occur while using the battery station:
Warning Indicator
| Warning Sound|
Description
---|---|---
Solid yellow
| /| Main board is abnormal and the power is limited
Blinks yellow once continuously| /|
The CPX503-3000 switching power supply is abnormal and the power is limited
Blinks red once continuously
| /| The CPX503-3000 switching power supply is unavailable or the fan stalled
Blinks red once continuously| Beeps once continuously|
The CPX503-3000 has experienced a critical error and there is no output
Solid red
| Beeps twice continuously|
Main board is abnormal and unavailable
If there are any abnormalities, connect the battery station to a remote controller and run the DJI MG or DJI Agras app to check more information. If the app indicates that a module is abnormal or broken, contact DJI or a DJI authorized dealer.
Updating Firmware
Follow the instructions below to update the firmware using the remote controller or DJI Assistant 2 for MG. Users will be notified through the app when firmware updates are available.
Using Remote Controller
- Connect the battery station to a remote controller using a USB-C cable and connect the battery station to a power outlet.
- Power on the remote controller and press the power button on the operation panel to power on the battery station.
- Run the DJI MG or DJI Agras app and follow the prompts to update the firmware. Make sure the remote controller remains connected to the internet while updating.
Using DJI Assistant 2 for MG
- Download DJI Assistant 2 for MG at https://www.dji.com/t30/downloads or https://www.dji.com/t10/downloads.
- Launch DJI Assistant 2 for MG and log in with your DJI account.
- Power on the battery station and connect the station to a computer via the USB-C port.
- Select “Battery Station / Inverter Generator” and click on Firmware Updates on the left panel.
- Select the firmware version that you wish to update to.
- Wait for the firmware to download. The firmware update will start automatically.
- The station will reboot automatically after the firmware update is complete.
|
- Before using the battery station, make sure there are no obvious defects on the ports or cables of the battery station (e.g., jams, breakages, or short circuits).
- DO NOT connect the batteries while updating the firmware of the battery station.
- DO NOT disconnect the battery station while updating the firmware of the battery station.
- Make sure the computer is connected to the internet.
- Retry if update fails
---|---
Storage and Maintenance
Battery Station Storage
When the battery station is not in use, disconnect the batteries from the battery station and the battery station from the power outlet. Follow the steps below to safely secure the charging cables.
- After disconnecting a battery, wrap the charging cable over the battery station.
- Make sure the end of the charging cable is securely attached to the corresponding storage on the side of the battery station.
|
- DO NOT store this product under direct sunlight, in rain, or in a damp environment.
- Keep the battery station away from heat, pressure, water, flammable gases, and corrosives.
---|---
Battery Station Maintenance
Clean the AC power dustproof cover and front dustpoof cover regularly to ensure the charging performance is unaffected.
Specifications
Specifications| T30 Intelligent Flight Battery (Model: CHX503-7000)| T10
Intelligent Flight Battery (Model: CHX503-3500)
---|---|---
Operating Temperature Range|
-5° to 45° C (23° to 113° F)
Dimensions|
300×280×230 mm
Output Channel|
2
Compatible Battery| T30 Intelligent Flight Battery| T10/T16/T20
Intelligent Flight Battery
**** Weight| Approx. 5.5 kg (without CPX503- 3000 Switching Power Supply)|
Approx. 5.1 kg (without CPX503- 3000 Switching Power Supply)
Note: Refer to the CPX503-3000 Switching Power Supply Product Information for current, input and output voltage.
Environmentally friendly disposal
Old electrical appliances must not be disposed of together with the residual
waste, but have to be disposed of separately. The disposal at the communal
collecting point via private persons is for free. The owner of old appliances
is responsible to bring the appliances to these collecting points or to
similar collection points. With this little personal effort, you contribute to
recycle valuable raw materials and the treatment of toxic substances.
Download the latest version from www.dji.com/t30 or www.dji.com/t10
This content is subject to change.
If you have any questions about this document, please contact DJI by sending a
message to DocSupport@dji.com
AGRAS and are trademarks of DJI.
Copyright © 2021 DJI All Rights Reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>