ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station User Manual

June 12, 2024
ENERNOVA

ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station TA Ultra 2160Wh 2000W Portable Power Station
User Manual

Charge first- Before using, plugitinto the power outlet until it is fully charged.

Safety Instructions

1.1 Disposal Guide

  1. The product contains high voltage AC output, please do not put your hand or handheld metal conductor into the AC outlet.
  2. Do not disassemble the product if you are not professionals because internal battery and circuit of the product have dangerous high energy which is able to cause electric shock, short circuit and other dangerous things to happen.
  3. Do not put the product in high temperature environment (more than 50 degrees Celsius) or near the fire to avoid the product from explosion or catching fire.
  4. The product is not a toy. Keep the product out of the reach of chil- dren.
  5. Do not use it in a damp environment.
  6. Please do not knock or hit the product.
  7. Itis strictly forbidden to disassemble the product.
  8. Itis strictly forbidden to use products with obvious damage.
  9. All parts of the product are environmental friendly and recyclable, please recycle according to local regulations.

1.2 Usage

  1. Please select the solar panel in accordance with the electrical para- meters specified by the manufacturer. It is forbidden to charge with solar panels whose voltage is higher than 50V.
  2. Please charge the battery within the temperature range of 0~45°C. Charging at too low temperature will shorten the cycle life of the battery.
  3. For long term storage (more than 3 months), it should be stored in a low humidity environment without corrosive gas at -10~50°C in a se- mi-electric state.
  4. If the power station is stored for more than 6 months, please charge and discharge the product 1-2 times every three months to extend the life of the battery.
  5. In order to preserve the power of the product, please turn off the product in time after using so as to avoid running out of the battery power (the device will have no-load loss as long as it is turned on).
  6. When the product runs out of power, please charge it in time.
  7. If the product emits abnormalities such as odor and overheat during charging or storage, please stop charging immediately and place it in an open place for observation from a distance to confirm safety, and contact the manufacturer or distributor after it.
  8. The product has a wireless charging function. If the wireless charging switch is turned on, the wireless charging function will be turned on. Please note that the charging part on the back of the phone cannot be made of metal (such as a bracelet). If there is metal, it will cause heat. Do not put metal objects or radio-sensitive items on the top of the power supply. Otherwise, it may cause abnormal heat or even damage!
  9. This product is a power station, please select the corresponding model according to the electrical equipment. The use of this product with excessive power and load is prohibited.
  10. When the short-circuit protection occurs after the product is con- nected to the device, if it is still protected after restarting, please do not restart it again. You should find the reason for the protection of the connected device, and then continue to use the  roduct after troubleshooting.
  11. This product is factory set according to the voltage standards of di- fferent countries. Please consult the dealer or check the product instru- ction manual before purchase and use.
  12. The mesh holes on both sides of the power supply are heat dissipa- tion holes, which are strictly prohibited to be blocked and a certain space should be reserved to ensure the heat dissipation effect.

Package List

Please kindly check all accessories are complete
If any charger cables missing, please feel free to contact us at: [email protected]

ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station -
List

Technical Specification

General Specs

Net Weight 55.11bs(25kg)
Dimensions 18.2in x 11.3in x 14.4in (46.3cm x 28.9cm x 36.6cm)
Capacity 2160Wh

Outputs

AC Output (x4) Pure Sine Wave| 2000W (Surge 4000W) tota1,100-120 Vac, 200-240Vac (50/60Hz)
USB-A Output (x4)| 5V – 2.4A, 12W Max (per port)
QC 3.0 Output (x2)| 5V – 3A, 9V – 2A, 12V – 1.5A, 18W Max
USB-C Output (x3)| 5V – 3A,9V – 3A,12V – 3A,15V – 3A,20V – 5A,100W Max*1 5V – 3A,9V – 3A,12V – 3A,15V – 3A,20V – 2.25A,45W Max (per port)’2
Car Power Output (xl)| 12.5V – 8A, 100W Max
Wireless Output (xl)| 15W

Input

AC Charger Input| 1500W Max
Solar Charge Input| 11-50V – 12A, 400W Max
Car Charge Input| 12V-24V – 10A, 100W

Battery

Cell Chemistry| Lithium Iron Phosphate
Operating Temperature| -10°C-40°C (14°F-104°F)
Recharging Temperature| I 0°C-40°C (32°F-104°F)
Warranty Life| 5 Years
Cycle Life| 3000 times to 800/o+ capacity

*Please note:
The following information has been obtained under supervised test conditions.

Getting Started

3.1 Input & Output Ports

ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station -
Ports

3.2LCD Screen

ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station - Ports
1

3.3 Battery Cells
3.3.1 Power Storage of Power Supplies:
The storage capacity of the power supply is the rated value. The rated power storage of the power supply is shown in the parameter label in the power supply manual, which is usually marked directly Wh, and the rated voltage (V) and rated capacity (mAh) are also marked, and the power storage (Wh) = rated voltage rated capacity (mAh) / 1000.
3.3.2 The Actual Power Discharged From the Power Supply:
The actual power discharged by the power supply is related to the fol- lowing parameters:

  1. Ambient Temperature
    The ambient temperature has a great influence on the power dischar- ged from the battery, for example, the range of electric vehicles will be shortened when they are used in cold areas. Generally speaking, with the rated 25°C(77°F) as the base, for every 10°C(50°F) decrease above 0 °C(32°F), the power discharged will be reduced by 10-15%. For every 10 °C(50°F) lower than 0°C, the power discharged will be reduced by 30%.

  2. Efficiency
    During the discharge process, the battery voltage needs to be transfor- med, which inevitably brings energy loss, especially the inverter (AC output) part, which is influenced by the ambient temperature and the power level of the equipment running, and the loss varies from 5-15%. Therefore, the measured power released from the output side under full load is only 85%-95% of the rated capacity.
    3.3.3 Power Supply With Load Time:
    Operating time = 2160Wh * 0.85 / your device’s operating power. (15% loss). The duration of our devices is based on laboratory data and may vary for specific device use.

3.4 The Output Power of the Power Station
3.4.1 Definition of Rated Power:
The rated output power of the power supply refers to the rated output power of the inverter (AC output) part, and the rest of the power is ge- nerally not marked because the power is relatively small compared to the inverter (AC output). Power supply can be AC part of the full power and other ports full power output at the same time.
3.4.2 Select Power Supply Power Considerations:
Some appliances such as hair curlers, laser printers, with motors and non- inverter class load (air conditioning, washing machines, etc.), such equipment start current is very large (3-5 times the nominal power), and the start time is long, about 10S, so the power exceeds a lot of this time is normal, choose the power supply to pay extra attention to the rated power of the power supply should be greater than the rated power of these appliances 3-5 times.
3.4.3 Power Supply Display Power Description:
Some appliances may be marked with their rated power, which itself also needs to calculate the actual operating efficiency or slightly diffe- rent according to the output voltage, so if the power displayed by the power supply itself is not much different from the rated power of the device itself (e.g. 20%), it is generally a normal phenomenon. If it exce- eds more, you need to verify the power of the equipment or need to confirm the existence of power or load failure.
3.5 Power Supply Alarm Function
3.5.1 When this product triggers the high temperature protection me- chanism, the icon will light up, it will automatically cut off all out- puts and enter the alarm reminder, while the screen icon will flash synchronously and the buzzer will sound 10 times.
3.5.2 This product will light up when the low temperature protection mechanism is triggered, the icon   will automatically cut off all out- puts and enter the alarm reminder, while the screen icon A will flash synchronously and the buzzer will sound 10 times.
3.5.3 This product will automatically cut off all outputs when it triggers the protection of other protection mechanisms and enter the alarm re- minder, while the screen’s icon will flash synchronously and the beep will sound 10 times.
3.6 EPS and Bypass Function
The product supports EPS and function, when connected to the utility for charging use, the product output will be directly through the utility port for output without going through the battery, greatly reducing the loss of battery life, while the moment of power  ailure can be switched to internal battery power within 30ms.
3.7 Auto Power Off
3.7.1 DC/AC/USB/wireless charger all output off state and without any operation, 1 minute automatic shutdown, or long press the “ON/OFF” key for 1 second to shut down.
3.7.2 If the output AC/DC/USB/wireless charger all open or open 1 of them, if all the output port without load, the default after 8 hours auto- matically shut down.
3.8Fan
When the power supply temperature exceeds 45°C, the fan will start running and speed up as the temperature rises in order to better help the power supply dissipate heat.
After the load is removed, the interior of the product is still in a high temperature state, so the fan will continue to run and dissipate heat to extend the life of the device. Typically, the fan will stop spinning after about 10 minutes of operation (depending on the load power and scene temperature).
3.9 Wireless Charging
Wireless charging is marked on the top of the power supply (the circle in the middle is the center of the wireless charging). When using the device, turn on the wireless charging switch and the wireless charging will turn on. Please put the phone in the center, wait a few seconds to wait for the power supply and the phone docking agreement to start wireless charging, at this time the phone will show the charging logo.

Recharging

The product has a charging protection function, once the productis fully charged, it will automatically stop charging. It is recommended to disconnect the charging connection in time after the product shows that it is fully charged.
4.1 Solar Charging
The XT60 charging port on the ETAUltra portable power station can be connected to a solar panel for charging (requires the use of an XT60 adapter cable in the solar panel).
The product is equipped with an internal MPPT system. When connec- ted to the solar panel, the product will automatically start charging and the battery icon will flash while the screen will show the charging power.
The power of the solar panel is greatly affected by light, so the input power may fluctuate, which is normal.

ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station - Solar
charging

4.2 AC Charging
Plug the AC input port of the charging cable into the AC power supply.
Plug the output port of the charging cable into the mains charging port on the side of the power supply and the battery icon starts to scroll while the charging power is displayed.

ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station - Solar charging
1

4.3 Car Charging
Plug the DC input of the Car charging cable into the Car cigarette ligh- ter. Plug the DC output of the car charging cable into the XT60 port of the portable power station and the battery icon will scroll while the charging power is displayed.

ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station - Solar charging
2

Troubleshooting

5.1 Charging Failure
5.1.1 The charging cable is not plugged into place. Please insert the input and output of the charging cable into place.
5.1.2 The ambient temperature is too high. It is dangerous to use the lithium battery at temperatures above the specified temperature, so if the ambient temperature is low or high, the product’s internal tempe- rature protection will stop charging and discharging. In this case, please wait for the product temperature to recover before using it.
5.1.3 Please make sure that the voltage version of the purchased power supply meets your local utility power supply standard (110V in the US, 100V in Japan, 230V in Europe).
5.2 Automatic Shutdown When Loading
5.2.1 The power of the connected load exceeds the specified value (after connecting the load, the power is turned on and the alarm icon on the display will light up after the output is automatically cut off).
Please note that some loads have a high starting current even though the nominal power is small, which will also cause the product to enter overload protection status.
5.2.2 Short-circuit fault exists in the rear load: Confirming this fault requires a professional to measure it with special tools (such as using a multimeter to measure the resistance of the rear device).
Overload or short-circuit fault can be confirmed with a normal low-power load. If there is no problem with a slightly lower-power load, it is usually a rear load overload or short-circuit fault.
5.2.3 The display protection mark lights up during operation, no output: the internal temperature of the inverter may be too high, the power station stops output, normal ambient temperature, normal load generally does not appear this situation, if it appears, please check ac- cording to the following recommendations. First, whether the ambient temperature is too high resulting in the internal temperature rise of the power station exceeds the specified value; second, both sides of the power station have heat dissipation holes, you need to leave at least 20cm of space for air circulation heat dissipation, pay attention not to place some light paper, plastic film, cloth and other soft materials, be- cause the fan will form suction when turning, these materials are ad- sorbed will greatly affect the power station heat dissipation resulting in internal protection. After eliminating the above abnormalities, the power station can be used again after cooling for a period of time.
5.2.4 Product failure. If the above abnormalities are excluded and the product still does not work properly, the power station itself may be malfunctioning and needs to be repaired.
5.3 Automatic Shutdown After Outputting
To save power consumption and to avoid not having power available when needed, the device will automatically shut down after 60 se- conds without turning on any port and without any operation if the output port switch is not turned on. If it needs to be used at this time, the power needs to be restarted.
5.4 Unable to Power On
5.4.1 Ambient temperature exceeds the specified temperature power internal protection. Lithium-ion batteries over the specified tempera- ture use is very easy to dangerous, so if the ambient temperature is very low or very high, the product’s internal temperature protection will not respond to the power on in the off state, if it has been turned on will stop charging and discharging. In this case, please wait for the product temperature to recover before using.
5.4.2 If the ambient temperature is normal, the battery may have been stored for too long causing the battery to run out of power, please plug in the charging cable to charge for at least 1 hour before use.
5.4.3 If the power station still cannot be turned on after taking the above measures, and there is no response when you press any button, the power station needs professional repair.
5.5 Short Discharge Time
5.5.1 The ambient temperature has a large impact on the battery discharge time, especially when the ambient temperature is below 0 degrees.
5.5.2 The product has a high number of cycles. The battery’s capacity will gradually decay as the number of cycles increases. Generally, when the rated cycle life is reached, the capacity is only 80% of the rated ca- pacity. This is a normal phenomenon and can continue to be used, but the discharge time will be shortened accordingly.
5.6 Wireless Charging Failure
5.6.1 Only when the Wireless Charge output switch is turned on can the wireless charging function be used.
5.6.2 Wrong position: Please move the phone to the corresponding position.
5.6.3 In order to wireless charging function properly, please do not use more than 3-5mm thick phone case.
5.6.4 The surface is hot: Because the coil of wireless charging is hot, so there will be a little heat at the wireless charger. But please pay extra attention to the back of the phone can not have metal substances, which will lead to abnormal heating and can not be charged properly.
5.7 Product Overheating
When the power station with a larger load, the inverter at the top and the battery at the bottom will generate a certain amount of heat, the cooling fan will start to dissipate heat, even so, the shell will still have a certain temperature rise, the temperature of the shell will reach about 40 degrees in the area where the heat is concentrated at full load (rela- ted to the ambient temperature), this situation is normal.
5.8 DC and USB Output Error
5.8.1 Corresponding switch is not turned on:
Make sure that the DC or USB switches are pressed and the correspon-n dingicons are lit.
5.8.2 Output overload protection:
When the DC or USB outputs are overloaded, the outputs will be auto- matically cut off and the alarm icon will flash. In this case, you need to disconnect the power of the connected device, then press the DC and USB switch again to make sure the alarm icon is no longer flashing and you can use it again.
5.8.3 No response when the device is turned on and the correspon- dingicon flashes:
Some DC devices have a high starting current (such as car vacuum cle- aners), and the power station may not respond at the moment of star- ting, or it may enter the protection state in a short time. When you en- counter this situation, please judge and operate as described in 5.8.2.

WARRANTY

We provide a 30-day money-back guarantee and a 5-year warran- ty(please register on our website to activate the 3-year extended war- ranty).

ENERNOVA ETA Pro 1050Wh 1200W Portable Power Station - QR
Code https://linktr.ee/enernovawarranty?utm_source=qr_code
For FAQs and more information, please visit:enernovatech.com/pages/policy
ENERNOVA(CHINA) CO., LTD.

Documents / Resources

| ENERNOVA ETA Ultra 2160Wh 2000W Portable Power Station [pdf] User Manual
ETA Ultra 2160Wh 2000W Portable Power Station, ETA Ultra, ETA Ultra Portable Power Station, 2160Wh 2000W Portable Power Station, 2160Wh Portable Power Station, 2000W Portable Power Station, Portable Power Station, 2000W Power Station, Power Station
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ENERNOVA User Manuals

Related Manuals