XARALYN 5820B Built-in Bio Ethanol Burner Instructions

June 6, 2024
Xaralyn

Built-in Bio Ethanol Burner

The safest fire!
The bioethanol burners with ceramic stone by Xaralyn provide a solution for situations where the ambiance of real fire is requested but no chimney is available or possible.
The bioethanol burners can be combined with one of the many surrounds of the Xaralyn collection, and can easily be placed and moved. No special adjustments are necessary for the installation. Our burners can also be used in existing fireplaces or in other creative custom-made situations. This manual contains instructions for correct and safe handling and building in.
Important! Read the manual provided with your bioethanol burner thoroughly for safe use!
Recommended building materials

  • Promafoury plate
  • Promatect® plate
  • Super-iso) plate
  • Promaglafe isolation blanket
  • Insulfrax isolation blanket
    Or other fire-resistant building materials.

Building in without built-in profile or unit
Recess for bioethanol burner without lip:

S (4114)  409 x 137 x 80 mm ()xwxh)
M (4120) 405 x 200 x 80 mm (1)cash)
 L (5820) 577 x 200 x 80 mm (lxwxh)

Recess for bioethanol burner with lip:

S (4114L) 409 x 137 x 80 mm (1)cw)ch)
L (5820) 575 x 200 x 80 mm ()xinch)
XL (8014LS) 800 x 137 x 80 mm (1)cwxh)
XXL (11814LS) 1180 x 137 x 80 mm (Ixwxh)

Top plate: 429 x 159 mm
Top plate: 597 x 220 mm
Top plate: 820 x 157 mm
Top plate: 1200 x 157 mm

Instructions for building in a bio ethanol burner

  • The recess for the burner should be made of a heat-resistant material, special profiles are available for situations where used material does not meet this requirement.
  • Make sure the material used on the top, back- and sidewalls of the burner is heat resistant.
  • Keep a safe distance of at least 400 nuns above the bioethanol burner and a minimal 50 mm on the sides.
  • In case a television is placed directly above the burner, we recommend a safety distance of at least SOO mm Always ask your TV supplier whether your TV is suitable for hanging above a fireplace.
  • After the bioethanol burner is placed in the recess make sure the bioethanol burner is leveled.

Building in with Built-in profile
Dimensions built-in profile:

Built-in profile S 40 x 530 x 260 mm (hxwxd)
Built-in profile L 40 x 690 x 330 mm (hxwxd)
Built-in profile XL 40 x 920 x 260 nun (hxwxd)
The opening for the built-in profile needs to be a minimum of S mm smaller than the size of the profile. The built-in profile is to be milled into the top panel of your design. If desired, this can be glued with heat-resistant adhesive. Keep enough space in the design from the top of the built-in profile, so the warmth from the burner will not damage the panel above.

Building in with built-in unit
Recess built-in unit:
Built-in unit S 640 x 420 x 210 mm (hxwxd) for burner M (4120)
Built-in unit L 670 x 590 x 220 mm (hxwxd)  for burner L (5820)
Built-in unit XL 486 x 922 x 217 nun (hxwxd)  for burner XL (8014)
Built-in unit XXL 486 x 1302 x 217 nun (hxwxd)  for burner XXL (11814)
height strip 91 mm
height strip 124 nun
It is also possible to use the XL and XXL units as a see-through option, as the back panel can be removed from these built-in units. They also have a strip on the front side at the bottom of the unit. This provides the option to keep the metal strip insight or to make the edge finish at the bottom higher (see pictures below). NB then the depth is 205mm.

The XL and XXL are also equipped with metal pipes on top. These can be used to connect a tube to a ventilation outlet in order to lead the heat to the room. If these are not necessary or desirable in your application, they can easily be removed.
Instructions for building in a bioethanol burner with a built-in unit

  • The recess for the bioethanol burner should be made of a heat-resistant material.
  • Make sure the material used on the top, back- and sidewalls of the burner is heat resistant.
  • Keep a space of a minimal 50 mm on both sides of the unit. This space is to be filled with insulation wool.
  • Place the built-in unit in the recess, make sure the unit is leveled.
  • Mount the built-in unit on the wall by attaching screws through the holes in the side strips.
  • Make sure the screws attaching the built-in unit are firmly stuck in the used material.
  • If desired, you can cover the side strips. Keep in mind that this must be done with heat-resistant material. Special profiles for covering the side strips are also available for the models L, XL and XXL.

A Vreekesweld 30 1721 PR Brock op langedijk The Netherlands
T r31(0)226 33 14 20
Einfoexaralyn.com
Wwwwxaralyn.com