oraimo OEB-E94D AirPods 2 Wireless Earbuds User Guide

June 6, 2024
oraimo

oraimo OEB-E94D AirPods 2 Wireless Earbuds User Guide

Package Contents

  • Charging Case

  • True Wireless Half In-Ear Earbuds

  • Micro USB Charging Cable

Product Overview

Product Overview
Product Overview

  1. Multi-Function Force Sensor
  2. Earbud Status Indicator
  3. Microphone
  4. Micro USB Charging Port
  5. Left Earbud
  6. Right Earbud
  7. Case Status Indicator

Basic Product Specifications

Earbuds

  • BT version : V5.0
  • Talk time : Up to 3 hours
  • Talk range :10m / 33ft
  • Music play time : Up to 3.5 hours
  • Weight : 4g (each earbud)
  • Battery capacity : 37mAh (each earbud)
  • Driver (full range) : 13mm x 2
  • Charging time : Approx. 2 hours
  • Standby time : Up to 82 hours

Charging Case

  • Weight : 31g
  • Charge times for earbuds: Up to 6 times
  • Battery capacity : 500mAh
  • Charging time : Approx. 3 hours

Using Your Earbuds

Turn On & Pairing
Earbuds will turn on and enter pairing mode automatically when taken out of the charging case.

Turn On & Pairing
Turn On & Pairing
Indicators table

  • Make sure the distance of the earbuds and your device is less than 1 meter / 3.3 feet at the first time of connection.

  • When turned on. the earbuds will automatically connect to the last connected device if available. If not, the earbuds will enter pairing mode.

  • Under any abnormal condition, return the earbuds to the charging case and then take out again.
    Turn Off
    The earbuds turn off automatically when placed back into the charging case.
    Turn Off

  • The earbuds will automatically turn off after 3 minutes if no device is connected.

Charging Your Earbuds & Case

Earbuds will be charged automatically once they are returned to the charging case

Charging Your Earbuds & Case

Earbud indicator

Case Status Indicator Status
Based on the case power level Running lamp first, then the lights will flash
based on the case power level and turn off after 4 seconds Charging the

earbuds
| Lights off| Earbuds fully charged

Charging the case

Case study indicator

  • Use the included Micro USB charging cable to charge the case.
  • To preserve battery lifespan, fully charge at least once every 45 days.

Controls

Controls
Controls
Controls

  • Attention
  • Use original or certified cables
  • Do not expose to liquids
  • Do not disassemble
  • Avoid dropping
  • Avoid extreme temperatures
  • Do not use the product outdoors during a thunderstorm
  • Do not use any corrosive cleaner/oil to clean

Considerate Hints

  1. Do not turn up the volume to a fair high level constantly as this could shorten the service life of this product or impair your hearing.
  2. When encounter any fault during operation, please cut off the power supply and disconnect the USB cable to prevent further damage to the product or other components.
  3. The wireless transmission range or connectivity could be affected by low battery power. In that case, please recharge immediately.

FCC ID: 2AXYP-OEB-E94D

FCC  Caution : Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and  (2) this device must accept any interference received, including interference that may cause undesired operation.

IMPORTANT NOTE :

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/IV technician for help.

The device has been evaluated to meet general RF exposure requirement The device can be used in portable exposure condition without restriction. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.

Customer Service

365 Days Warranty

Email: hello.ab@oraimo.com

Caution :

  1. Risk of explosion if battery is replaced by an incorrect type, dispose of used batteries according to the instructions.
  2. The product shall only be connected to a USB interface of version USB2.0
  3. Adapter shall be installed near the equipment and shall be easily accessible.
  4. EUT Temperature: -20C — +60C (Standalone),-20°C —+40°C(With Parts).
  5. To prevent possible hearing damage, do not listen at high volume levels for long periods.

Operating Frequency (RF):

BT: 2402-2480MHz

Modulation mode :

GFSK, n/4-DQPSK, 8-DPSK(BT) GFSK (BLE)

Warning label

EU Declaration of Conformity

in accordance with Annex VI of Directive 2014/53/EU of the European Parliament and of the Council

  1. For the following Radio equipment: Model: OEB-E94D Product: True Wireless Half In-Ear Earbuds Trade name or Brand: oraimo Software / Hardware number: V2.0 /V2.0

  2. Name and address of the manufacturer or his authorised representative: Manufacturer: ORAIMO TECHNOLOGY LIMITED Add: ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL

  3. This declaration of conformity is issued under the sole responsibility of the Manufacturer.

  4. Object of the declaration (identification of the radio equipment allowing traceability; it may include a colour image of sufficient clarity where necessary for the identification of the radio equipment):

  5. The object of the declaration described above is in conformity with the relevant Union harmonization legislation: Directive 2014/53/EU (RED)

  6. References to the relevant harmonized standards used or references to the other technical specifications in relation to which conformity is declared: Article 3.1a Health: EN 62479: 2010
    Article 3.1a Electrical Safety: EN62368-1:2014+A11:2017
    Article 3.1b: ETSI EN 301 489-1 V2.2.3 (2019-11)
    Draft ETSI EN 301 489-17 V3.2.2 (2019-12)
    Article 3.2: ETSI EN 300 328 V2.2.2 (2019-07)

  7. Notified Body Name: MET Laboratories, Inc.
    Notified Body Number: 0980
    Notified Body Assessment Performed: Module B/C on Article 3.1a, 3.1b, 3.2 and 3.3 Technical File Identification Number N/A

  8. Where applicable, description of accessories and components, including software, which allow the radio equipment to operate as intended and covered by the EU declaration of conformity: User instructions are provided in the User Manual. The Software and Hardware versions are specified above.

  9. Additional information: Referring to Article 10.2 of the Directive, this equipment is so constructed that it can be operated in all Member States, without infringing applicable requirements on the use of radio spectrum. Referring to Article 10.10 of the Directive, there are no restrictions on putting this equipment into service or of requirements for authorisation of use. Please refer to the User Manual for details.

On behalf of:
Manufacturer ORAIMO TECHNOLOGY LIMITED
Add: ROOM 604 6/F SOUTH TOWER WORLD FINANCE CTR HARBOUR CITY 17 CANTON ROAD TST KL (place and date of issue): Shenzhen, 2019-12-25 (name, function): Yiting Luo/ Manager

(signature):

Warranty Certificate

Name :
Address :
Tel. No. :
Date of purchase : (dd/mm/yy)
Store name :
Warranty period :

Warranty Terms & Conditions

  • All quality-related defects on items sold directly by oraimo or oraimo’s authorized resellers are covered by an extensive warranty, starting from the date of purchase.
  • oraimo’s limited warranty is restricted to the country of purchase. The limited warranty is void on items taken outside the country they were originally bought in or shipped to directly from an authorized online purchase.
  • This warranty covers only original oraimo products. It is not applicable to normal wear and tear, or any defects arising from damage caused by misuse of this product.
  • Warranty is for the primary product only nor transferable. Any free additional product(s) are not covered in this warranty.
  • If the product fails regardless of usage in compliance with the instruction manual and other written precaution, replacement will be provided free of charge.
  • To receive replacement, bring the warranty certificate and the product itself to the store from where you have purchased the product.

For more information, please visit:

Facebook: @oraimo accessories
Instagram: @oraimoclub
Twitter; @oraimomate

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals