LEONTON EG5-2004-SFP Series 20-Port Industrial Gigabit Managed Ethernet Switch User Manual
- June 3, 2024
- Leonton
Table of Contents
EG5-2004-SFP Series 20-Port Industrial Gigabit Managed Ethernet Switch
LEONTON
EG5-2004-SFP Series
(EG5-2004-SFP / EG5-2004-SFP-T)
User Manual
© Copyright 2020 Leonton Technologies Co., Ltd. All Rights Reserved This
document contains information, which is protected by copyright. Reproduction,
adaptation or translation without prior permission is prohibited, except as
allowed under the copyright laws.
Disclaimer Leonton Technologies, Co. Ltd. provides this manual without
warranty of any kind, expressed or implied, including but not limited to the
implied warranties of merchantability and fitness for a particular purpose.
Leonton Technologies, Co. Ltd. may make improvements and/or changes to the
product and/or specifications of the product described in this manual, without
prior notice. Leonton Technologies, Co. Ltd. will not be liable for any
technical inaccuracies or typographical errors found in this guide. Changes
are periodically made to the information contained herein and will be
incorporated into later versions of the manual. The information contained is
subject to change without prior notice.
FCC Notice This equipment has been tested and found to comply with the limits
for a Class-A digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy. It may cause harmful interference to
radio communications if the equipment is not installed and used in accordance
with the instructions. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation
between the equipment and receiver. · Connect the equipment into an outlet on
a circuit different from that to which the receiver
is connected. · Consult the dealer or an experienced radio/TV technician for
help.
Caution: Any changes or modifications not expressly approved by the grantee of
this device could void the user’s authority to operate the equipment.
Déclaration FCC Cet équipement a été testé et reconnu conforme aux limites de
la classe A pour les équipements numériques, conformément à la section 15 des
Réglementations FCC. Ces limites sont conçues pour fournir une protection
raisonnable contre toutes interférences nuisibles dans un milieu résidentiel.
Cet équipement génère, utilise, et peut émettre de l’énergie de fréquence
radio et, s’il n’est pas installé et utilisé conformément au manuel
d’instruction, peut perturber la réception radio. Cependant, il n’est pas
garanti que l’équipement ne produira aucune interférence dans une installation
particulière. Si cet équipement cause des interférences nuisibles à la
réception radio ou télévisée, qui peuvent être déterminées en l’éteignant et
le rallumant, l’utilisateur est encouragé à essayer de remédier au problème en
prenant les mesures suivantes: * Réorienter ou déplacer l’antenne réceptrice.
- Augmenter la distance entre l’équipement et le récepteur. Connecter
l’équipement à une prise secteur sur un circuit différent de celui utilisé par
le récepteur. Consulter le négociant ou un technicien radio/TV expérimenté.
Caution: Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
ATTETNION: Tout changement ou modification non expressément approuvé par le concessionnaire de cet appareil pourrait annuler l’autorité de l’utilisateur à utiliser l’équipement.
CE Mark Warning This is a Class-A product. In a domestic environment this
product may cause radio interference in which case the user may be required to
take adequate measures.
CE Mark AVERTISSEMENT Ceci est un produit de classe A. Dans un environnement
domestique, ce produit peut être utilisé en présence d’interférences radio.
This document is the current official release manual. Please check our website
(www.leonton.com) for any updated manual or contact us by e-mail
(sales@leonton.com).
Contents
Overview………………………………………………………………………………………………………………………………………………………………………. 1 Key
Features ……………………………………………………………………………………………………………………………………………………………. 1
Package Contents…………………………………………………………………………………………………………………………………………………… 2
Safety Precaution……………………………………………………………………………………………………………………………………………………. 2
Hardware Description ………………………………………………………………………………………………………………………………………………..
3 Physical Dimensions………………………………………………………………………………………………………………………………………………. 3
Front Panel ………………………………………………………………………………………………………………………………………………………………. 4
Top View ………………………………………………………………………………………………………………………………………………………………….. 4 LED
Indicators …………………………………………………………………………………………………………………………………………………………. 5
Ethernet Ports …………………………………………………………………………………………………………………………………………………………. 6
Cabling……………………………………………………………………………………………………………………………………………………………………… 7
Wiring the Power Inputs ………………………………………………………………………………………………………………………………………..
9
Mounting Installation……………………………………………………………………………………………………………………………………………….10
DIN-Rail Mounting ………………………………………………………………………………………………………………………………………………. 10
Wall Mounting ………………………………………………………………………………………………………………………………………………………. 12
Hardware Installation
……………………………………………………………………………………………………………………………………………….14 Installation Steps
………………………………………………………………………………………………………………………………………………….. 14
Trouble Shooting ……………………………………………………………………………………………………………………………………………………… 15
Overview
This series is rated IP30 and installation by DIN Rail. Each unit of this
industrial gigabit managed Ethernet switch series has 1610/100/1000Tx and
4100/1000 Base-(F)X SFP Slots, suitable for applications that require high
bandwidth communication. In order to prevent unregulated voltage, this series
provides high EFT and ESD protection. This also allows it to function in harsh
environments, as well as support power redundancy with a dual power input
design with reverse polarity protection. With one model having an operating
temperature of -10°C ~ 65°C, and another with a wide operating temperature of
-40°C ~ 75°C, this series is designed to meet any needs for industrial
automation application and harsh environments.
Key Features
Interface & Performance · All Copper ports support auto MDI/MDI-X function ·
EG5-2004-SFP – Embedded 1610/100/1000Tx + 4100/1000 Base-(F)X SFP Slots ·
Store-and-forward switching architecture · 8K MAC Address Table · Supports
9.6Kbytes Jumbo Frame · 4Mbits memory buffer
Power Input · EG5-2004-SFP: Dual 12-48VDC redundant power inputs, with SELV
output certified by UL61010-2-201 · 2 removable 4-contact terminal block ·
Max. current 1.31A
Certification · CE/FCC · UL 61010-1 · UL 61010-2-201 · IEC 61850-3
Operating Temperature · Standard operating temperature model: -10°C ~ 65°C ·
Extended operating temperature model (T): -40°C ~ 75°C
Case/Installation · IP30 protection (not certified by UL) · Installation in
pollution degree to environment · DIN-Rail and Wall mount design · indoor use
· Pollution degree 2
1
Package Contents
· 1 – EG5-2004-SFP(-T) x 1 · 2 – Wall mounting brackets and screws x 1 · 3 –
Quick installation guide x 1 · 4 – RJ45 to DB9 Serial Console cable x 1
Safety Precaution
Attention If the DC voltage is supplied by an external circuit, please use a
protection device on the power supply input. Supply by UL Listed industrial
use power. The industrial Ethernet switch’s hardware specs, ports, cabling
information, and wiring installation will be described within this user
manual. ATTETNION Si la tension CC est fournie par un circuit externe,
veuillez utiliser un dispositif de protection sur l’entrée d’alimentation.
Fourniture par courant industriel homologué UL. Les spécifications
matérielles, les ports, les informations de câblage et l’installation du
câblage du convertisseur de média industriel seront décrits dans ce manuel
d’utilisation.
2
Hardware Description
Physical Dimensions
Figure 2.1, below, shows the physical dimensions.
67mm (W) x 142mm (H) x 99mm (D)
Figure 2.1: Physical Dimensions
3
Front Panel
The front panel of the EG5-2004-SFP series industrial gigabit managed Ethernet
switch is shown below in Figure 2.2.
Figure 2.2: The Front Panel
Top View
Figure 2.3, below, shows the top panel of the EG5-2004-SFP series switches
that is equipped with two 4-pin removal terminal block connector for dual DC
power inputs (12-48VDC).
Figure 2.3: Top Panel View
4
LED Indicators
There are LED light indicators located on the front panel of the industrial Ethernet switch that
display the power status and network status. Each LED indicator has a different color and has its
own specific meaning, see below in Table 2.1.
LED P1 P2
STATUS
MASTER RING
1G (LAN Port 1-16)
10/100 (LAN Port 1-16)
Color Green Green Green Red Green Green Green
Green
L/A (SFP Port 17-20)
Green Amber
On Off On Off On
Off
On Off On Off On Flashing Off On Flashing Off On Flashing Off On Flashing Off
Description Power input 1 is active Power input 1 is inactive Power input 2 is
active Power input 2 is inactive No configured event happens 1. System booting
2. Configured event happens ERPS Owner Mode (Ring Master) is ready ERPS Owner
Mode is not active ERPS Ring Network is active and works well ERPS Ring
Network is not active Connected to network, 1000Mbps
Networking is active
Not connected to network Connected to network, 10/100Mbps Networking is active
Not connected to network Connected to network, 1000Mbps Networking is active
Not connected to network Connected to network, 100Mbps Networking is active
Not connected to network
Table 2.1: LED Indictors
5
Ethernet Ports
RJ-45 Ports (Auto MDI/MDIX) The RJ-45 ports are auto-sensing for 10Base-T,
100Base-TX or 1000Base-T devices connections. Auto MDI/MDIX means that the
switch can connect to another switch or workstation without changing the
straight-through or crossover cabling. See the figures as below for straight-
through and crossover cabling schematics.
10/100BASE-T(X) RJ-45 Pin Assignments (Table 2.2)
Crossover Cable
Straight Through Cable
Pin Number / Signal Pin Number / Signal Pin Number / Signal Pin Number / Signal
1 / RX+
3 / TX+
1 / RX+
1 / TX+
2 / RX-
6 / TX-
2 / RX-
2 / TX-
3 / TX+
1 / RX+
3 / TX+
3 / RX+
6 / TX-
2 / RX-
6 / TX-
Table 2.2
6 / RX-
1000BASE-T RJ-45 Pin Assignments (Table 2.3) Crossover Cable
Straight Through Cable
Pin Number / Signal Pin Number / Signal Pin Number / Signal Pin Number / Signal
1 / TP0+
3 / TP1+
1 / TP0+
1 / TP1+
2 / TP0-
6 / TP1-
2 / TP0-
2 / TP1-
3 / TP1+
1 / TP0+
3 / TP1+
3 / TP0+
4 / TP2+
7 / TP3+
4 / TP2+
4 / TP3+
5 / TP2-
8 / TP3-
5 / TP2-
5 / TP3-
6 / TP1-
2 / TP0-
6 / TP1-
6 / TP0-
7 / TP3+
4 / TP2+
7 / TP3+
7 / TP2+
8 / TP3-
5 / TP2-
8 / TP3-
Table 2.3
8 / TP2-
Note: “+” and “-” signs represent the polarity of the wires that make up each wire pair.
6
Cabling
Use the four twisted-pair, category 5e, or the above cabling for RJ-45 port
connections. The cable between the switch and the link partner (switch, hub,
workstation, etc.) must be less than 100 meters (328 ft.) long. The small
form-factor pluggable (SFP) is a compact optical transceiver used in optical
communications for both telecommunication and data communication applications.
Caution: Please employ optional optical transceiver (SFP) that complies with
IEC 60825-1 and classified as Class 1 laser product. Attention: Veuillez
utiliser un émetteur-récepteur optique (SFP) conforme à la norme CEI 60825-1
et classé comme produit laser de classe 1. To connect the transceiver and LC
cable, please follow below steps: Step 1 Insert the SFP transceiver module
into the SFP slot as shown below in Figure 2.4. Notice that the triangle mark
is at the bottom of the SFP slot. Figure 2.5 shows SFP transceiver module was
inserted.
Figure 2.4: Transceiver to the SFP Module
Figure 2.5: Transceiver Inserted
7
Step 2 Insert the fiber cable of the LC connector into the transceiver as
shown below in Figure 2.6.
Figure 2.6: LC Connector to the Transceiver To remove the LC connector from
the transceiver, please follow the steps shown below:
Step 1 Press the upper side of the LC connector from the transceiver and pull
it out to release as shown below in Figure 2.7
Figure 2.7: Remove LC Connector Step 2 Push down the metal clasp and pull the
transceiver out by the plastic part as shown
below in Figure 2.8
Figure 2.8: Pull Out from the SFP Slot
8
Wiring the Power Inputs
Caution: Please follow the below steps to insert the power wire. Attention:
Veuillez suivre les étapes ci-dessous pour insérer le câble d’alimentation.
Step 1 Insert the positive and negative wires into the PWR1 (V1-, V1+) and
PWR2 (V2-, V2+)
contacts on the terminal block connector as shown below in Figure 2.9.
Figure 2.9: Power Terminal Block Step 2 Tighten the wire-clamp screws to
prevent the wires from loosening, as shown below in
Figure 2.10.
Figure 2.10: Power Terminal Block Caution: Only use copper conductors, 125°C,
tighten to 5 in-lbs (0.56 Nm). The wire gauge for the terminal block should
range between 18~20 AWG. Attention: Utilisez uniquement des conducteurs en
cuivre, 125°C, serrez à 5 in-lbs (0.56 Nm). Le calibre du bornier doit être
compris entre 18 et 20 AWG.
9
Mounting Installation
DIN-Rail Mounting
The DIN-Rail is pre-installed on the industrial Ethernet switch from the
factory. If the DIN-Rail is not on the industrial Ethernet switch, please see
Figure 3.1 to learn how to install the DIN-Rail on the switch.
Figure 3.1: The Rear Side of the Switch and DIN-Rail Bracket Follow the steps
below to learn how to hang the industrial Ethernet switch. Step 1. Use the
screws to install the DIN-Rail bracket on the rear side of the industrial
Ethernet
switch. Step 2. To remove the DIN-Rail bracket, do the opposite from Step 1.
Step 3. After the DIN-Rail bracket is installed on the rear side of the
switch, insert the top of the
DIN-Rail on to the track as shown below in Figure 3.2.
10
Figure 3.2: Insert the Switch on the DIN-Rail Step 4. Lightly pull down the
bracket on to the rail as shown below in Figure 3.3.
Figure 3.3: Stable the Switch on DIN-Rail Step 5. Check if the bracket is
mounted tightly on the rail. Step 6. To remove the industrial Ethernet switch
from the rail, do the opposite from the above
steps.
11
Wall Mounting – in the industrial control panel
Follow the steps below to mount the industrial Ethernet switch using the wall
mounting bracket as shown below in Figure 3.4. Step 1. Remove the DIN-Rail
bracket from the industrial Ethernet switch by loosening the screws. Step 2.
Place the wall mounting brackets on the top and bottom of the industrial
Ethernet switch. Step 3. Use the screws to screw the wall mounting bracket on
the industrial Ethernet switch. Step 4. Use the hook holes at the corners of
the wall mounting bracket to hang the industrial
Ethernet switch on the wall. Step 5. To remove the wall mount bracket, do the
opposite from the steps above.
Figure 3.4: Remove DIN-Rail Bracket from the Switch and Install the Wall Mount
Bracket
12
Below, in Figure 3.5 are the dimensions of the wall mounting bracket. Figure
3.5: Wall Mounting Bracket Dimensions
13
Hardware Installation
Installation Steps
This section will explain how to install EG5-2004-SFP series. Installation
Steps Step 1. Unpack the industrial Ethernet switch from the original packing
box. Step 2. Check if the DIN-Rail bracket is screwed on the industrial
Ethernet switch.
· If the DIN-Rail is not screwed on the industrial Ethernet switch, please
refer to the DIN-Rail Mounting section for DIN-Rail installation.
· If you want to wall mount the industrial Ethernet switch, please refer to
the Wall Mounting section for wall mounting installation.
Step 3. To hang the industrial Ethernet switch on a DIN-Rail or wall, please
refer to the Mounting Installation section.
Step 4. Power on the industrial Ethernet switch and then the power LED light
will turn on. · If you need help on how to wire power, please refer to the
Wiring the Power Inputs section. · Please refer to the LED Indicators section
for LED light indication. Step 5. Prepare the twisted-pair, straight-through
category 5 cable for Ethernet connection. Step 6. Insert one side of the RJ-45
cable into switch’s Ethernet port and on the other side into the networking
device’s Ethernet port, e.g. switch PC or server. The Ethernet port’s (RJ-45)
LED on the industrial Ethernet switch will turn on when the cable is connected
to the networking device. · Please refer to the LED Indicators section for LED
light indication. Step 7. When all connections are set and the LED lights all
show normal, the installation is complete.
14
Trouble Shooting
Verify you have the right power cord or adapter. Never use a power supply or
adapter with a non-compliant DC output voltage or it will burn the equipment.
Select the proper UTP or STP cable in order to construct the network. Use an
unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45
connections: 100 Category 5e for 10/100/1000Mbps. Also be sure that the length
of any twisted-pair connection does not exceed 100 meters (328 feet).
Diagnosing LED Indicators: To assist in identifying problems, the switch can
be easily monitored with the LED indicators which help to identity if any
problems exist. Please refer to the LED Indicators section for LED light
indication.
If the power indicator LED does not turn on when the power cord is plugged in,
the user may have a problem with the power cord. Check for loose power
connections, power losses or surges at the power outlet. Please contact
Leonton for technical support service, if the problem still cannot be
resolved.
If the industrial switch LED indicators are normal and the connected cables
are correct but the packets still cannot transmit, please check the system’s
Ethernet devices’ configuration or status.
15
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>