Milesight UR35 Industrial Router Pro Series User Guide
- June 6, 2024
- Milesight
Table of Contents
Milesight UR35 Industrial Router Pro Series
Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide.
- The device must not be modified in any way.
- Do not place the device close to objects with naked flames.
- Do not place the device where the temperature is below/above the operating range.
- Do not power on the device or connect it to another electrical device when installing.
- Check lightning and water protection when used outdoors.
- Do not connect or power the equipment using cables that have been damaged.
Related Documents
This Start Guide only explains the installation of Milesight UR35 router.
For more functionality and advanced settings, please refer to the relevant
documents as below.
Document | Description |
---|---|
UR35 Datasheet | Datasheet for UR35 industrial cellular router. |
UR35 User Guide | Users could refer to the guide for instruction on how to log |
in the web GUI, and how to configure all the settings.
The related documents are available on the Milesight website: https://www .milesight-iot.com
Declaration of Conformity
UR35 are in conformity with the essential requirements and other relevant
provisions of the CE, FCC, and RoHS. All rights reserved.All information in
this guide is protected by copyright law. Whereby, no organization or
individual shall copy or reproduce the whole or part of this user guide by any
means without written authorization from Xiamen Milesight IoT Co., Ltd.
For assistance, please contact Milesight technical support:
- Email: iot.support@milesight.com
- Tel: 86-592-5085280
- Fax: 86-592-5023065
- Address: Building C09, Software Park III, Xiamen
Revision History
Date | Doc Version | Description |
---|---|---|
Aug. 1, 2019 | V 1.0 | Initial version |
Feb. 11, 2020 | V 1.1 | 1. Replace serial port picture; |
2. Delete reboot descriptions of reset button
Aug. 26, 2020| V 1.2| 1. Web GUI change;
2. 2.Add -485 model
Nov. 20, 2020| V 2.0| Layout replace
Dec. 1, 2021| V 2.1| Update cellular pictures
Packing List
Before you begin to install the UR35 router, please check the package contents
to verify that you have received the items below.
If any of the above items is missing or damaged, please contact your sales representative.
Hardware Introduction
Overview
- Wi-Fi Antenna Connector
- AUX Antenna Cellular Connector
- AUX Antenna Cellular Connector
- MAIN Cellular Antenna Connector
- LED Indicator Area
- POWER: Power Indicator
- SYSTEM: Status Indicator
- Wi-Fi: Wi-Fi Indicator
- VPN: VPN Indicator
- SIM: SIM Status Indicator
- Signal Strength Indicator
- Ethernet Port & Indicator
- Grounding Stud
- SIM and Reset Button Holder
- Power Connector
- Serial Port & I/O
Dimensions (mm)
Serial & IO & Power Pinouts
PIN | RS232 | RS485 | DI | DO | Description |
---|---|---|---|---|---|
1 | — | — | IN | — | Digital Input |
2 | GND | — | GND | — | Ground |
3 | — | B | — | — | Data – |
4 | TXD | — | — | — | Transmit Data |
5 | — | — | — | COM | Common Ground |
6 | — | — | — | OUT | Digital Output |
7 | — | A | — | — | Data + |
8 | RXD | — | — | — | Receive Data |
Note:
For -RS485 model, RXD—>A, TXD—>B.
PIN | Description | Wire Color |
---|---|---|
9 | Positive | Red |
10 | Negative | Black |
LED Indicators
LED | Indication | Status | Description |
---|---|---|---|
POWER | Power Status | Off | The power is switched off |
On | The power is switched on |
SYSTEM
|
System Status
| Green Light| Static: Start-up
Blinking slowly: the system is running properly
Red Light| The system goes wrong
VPN| VPN Status| Off| VPN is disconnected
Green Light| VPN is connected
Wi-Fi
|
Wi-Fi Status
| Off| Wi-Fi is disabled
Green Light| Static: Wi-Fi is enabled
Blinking slowly: sending or receiving data via Wi-Fi
SIM
|
SIM Card Status
| Off| SIM1 or SIM2 is registering or fails to register (or there
are no SIM cards inserted)
Green Light
| Blinking slowly: SIM1 (as primary SIM) has been
registered and is ready for dial-up
Blinking rapidly: SIM1(as primary SIM) has been
registered and is dialing up now
Static: SIM1 (as primary SIM) has been registered and
dialed up successfully
Orange Light| Blinking slowly: SIM2 (as primary SIM) has been
registered and is ready for dial-up
Blinking rapidly: SIM2 (as primary SIM) has been
registered and is dialing up now |
---|
Static: SIM2 (as primary SIM) has been registered and
dialed up successfully
Signal Strength
|
Signal 1/2/3
| Off| No signal
Green Light
| Static/Off/Off: weak signals with 1-10 ASU (please
check if the antenna is installed correctly, or move the antenna to a suitable location to get better signal)
Static/Static/Off: normal signals with 11-20 ASU
(average signal strength)
Static/Static/Static: strong signals with 21-31 ASU
(signal is good)
Reset Button
The reset button is under the SIM slots.
Function | Description |
---|---|
SYSTEM LED | Action |
Reset
| Blinking| Press and hold the reset button for more than 5 seconds.
Static Green →
Rapidly Blinking
| Release the button and wait.
Off → Blinking| The router is now reset to factory defaults.
Ethernet Port Indicator
Indicator | Status | Description |
---|
Link Indicator (Orange)
| On| Connected
Blinking| Transmitting data
Off| Disconnected
Hardware Installation Environmental Requirements
- Power Input: 9-48 VDC (48 VDC is needed for PoE output)
- Power Consumption: Typical 3.9 W (Max 4.6 W)
- Operating Temperature: -40°C to 70°C (-40°F -158°F)
- Relative Humidity: 0% to 95% (non-condensing) at 25°C/77°F
SIM Card/Micro SD Card Installation
UR35 do not support hot-plug. Please cut off the power before inserting or
take off cards.
- Unscrew the cover of the SIM card then take it off.
- Put SIM card/Micro SD into the slot and screw it up.
Antenna Installation
Rotate the antenna into the antenna connector accordingly. The external
antenna should be installed vertically always on a site with a good
signal.
Router Installation
The router can be placed on a desktop or mounted to a wall or a DIN rail.
DIN Rail Mounting (Measured in mm)
Use 2 pcs of M3 × 6 flat head Phillips screws to fix the mount clip to the
router, and then hang the device to the DIN rail. The width of DIN rail is
3.5cm. Recommended torque for mounting is 1.0 N·m, and the maximum allowed is
1.2 N·m.
Wall Mounting (Measured in mm)
Use 2 pcs of M3 × 6 flat head Phillips screws to fix the wall mounting
bracket to the router, and then use 2 pcs of M3 drywall screws to mount the
router associated with the wall plugs on the wall. Recommended torque for
mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.
Protective Grounding Installation
Remove the grounding nut, then connect the grounding ring of the cabinet’s
grounding wire onto the grounding stud and screw up the grounding nut.
The router must be grounded when deployed. According to the operating environment, the ground wire should be connected with the grounding stud of router.
Log in to the Web GUI of Router
Please connect PC to LAN port of UR35 router. PC can obtain an IP address,
or you can configure a static IP address manually. The following steps are
based on Windows 10 operating system for your reference.
IP Address: 192.168.1.1
Username: admin
Password: password
Go to “Control Panel” → “Network and Internet” → “Network and Sharing Center”,
then click “Ethernet” (May have different names).
Go to “Properties” → “Internet Protocol Version 4(TCP/IPv4) ”, select “Obtain an IP address automatically” or “Use the following IP address”, then assign a static IP manually within the same subnet of the device.
Open a Web browser on your PC (Chrome is recommended), type in the IP address 192.168.1.1, and press Enter on your keyboard. Enter the username, password, and click “Login”.
If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes. When you login with the default username and password, you will be asked to modify the password. It’s suggested that you change the password for the sake of security. Click the “Cancel” button if you want to modify it later.
After you login the Web GUI, you can view system information and perform configuration on the router.
Network Configuration
This chapter explains how to connect UR35 to the network via WAN connection
or cellular.
Ethernet WAN Configuration
Go to “Network > Interface > WAN” to select connection type and configure
WAN parameters, click “Save & Apply” button to make the changes take
effect.
- Connect WAN port to another network device like a modem.
- Go to “Network > Interface > Link Failover” to rise the WAN priority to 1.
- Open your preferred browser on PC, then type any available web address into the address bar and see if it is able to visit the Internet via the UR35 router.
Cellular Connection Configuration
Take inserting SIM card into SIM1 slot as an example; please refer to the
following detailed operations. A. Go to “Network > Interface > Cellular >
Cellular Setting” to configure APN, PIN code or other cellularinfo, click
“Save” and “Apply” to save the configuration.
Go to “Network > Interface > Link Failover” to enable SIM1 and rise link priority of SIM1. Click to configure ICMP ping detection information.Click “Status > Cellular” to view the status of the cellular connection. If it shows “Connected”, it means SIM1 has dialed up successfully. On the other hand, you can check the status of SIM indicator. If it keeps on green light statically, it means SIM1 has dialed up successfully. Open your preferred browser on PC, then type any available web address into the address bar and see if it is able to visit the Internet via the UR35 router.