My Green Lighting 21509103 Tin Maxi Light Sensor Instructions
- June 6, 2024
- My Green Lighting
Table of Contents
My Green Lighting 21509103 Tin Maxi Light Sensor
INSTRUCTIONS
Please read these instructions carefully before attempting to install this fitting. It is advisable to keep these instructions in a safe place for future reference. If this fitting is installed by a contractor, the contractor should ensure that the customer has a copy of these instructions.
Sensor specifications
-
Voltage: 230 volts AC
-
Max load: I 00 watt maximum
-
Angle of detection: 110 degrees
-
Lux operation: I 0-20000LUX
-
Time on:5 seconds-5 min. (approx.) from initial triggering.
NOTE! If triggered within this period, another triggered timeN is added to time already run. -
Max. detection range: Up to 8 meters approx. depending on weather conditions and mounting height.
NOTE! The 8111 detection range applies when a person is walking across the detection area, not walking towards the sensor. If a person is walking towards the sensor and I .Sm to the left or right of it, the detection range is typically between 4m and 6m -
Mounting height: 1.5 to 2.5 meters approx.
-
Ambient operating temp. range: -10° to +50° Celsius
Operation
Time: regulate triggered time 5 seconds-Smin Distance: regulate detection range up to 8 metres approx Lux: regulate lux I 0-20000
Note
We do not recommend using low energy-saving lamps in this fixture.
Troubleshooting
When replacing the lamp or servicing the fitting, turn the power off at the mains and allow the lantern to cool.
FAULT | POSS . IBLE CAUSE | SOLU . | TION |
---|---|---|---|
Unit will not work at all | . No power |
Lamp not fitted correctly or
broken
. __ Incorrect wiring
| .
.
| Check power and fuse Check lamp
Check wiring
Unit will not work when in normal
operation
| .| Area too light, e.g. lighting nearby| .| Re-position lantern if
required
Sensing range too short| Unit is fixed too high, or angle of
approach into
. detection bands is incorrect Other lighting interfering with
the sensitivity of the PIR
sensor
| Move the unit to a lower height and/or change the angle of
. approach
Move lantern away from other
lighting
. .
Lamp on all the time| Wrongly wired| Check wiring
If Normal Mode lamp stays on for more than 5 minutes| | PIR
(sensor) has been triggered again within the 5 minutes time period (sec
specification)
| . .| Light will automatically switch off approximately 5 minutes after
the last signal the PIR receives
Lamp false triggers| Lantern badly positioned High winds| Reposition
lantern
Temporary situation. If annoying, switch lantern off
Read User Manual Online (PDF format)