guardian technologies H975AR 1 Gallon Table Top Ultrasonic Humidifier Instruction Manual
- June 6, 2024
- guardian technologies
Table of Contents
guardian technologies H975AR 1 Gallon Table Top Ultrasonic Humidifier
READ AND SAVE THESE INSTRUCTIONS
WARNINGS
Failure to comply with the warnings listed below may result in electric shock
or serious injury. This product should be used only in accordance with the
specifications outlined in this manual. Usage other than what has been
specified here may result in serious injury.
- CAUTION: To reduce the risk of severe burns, keep this product out of the reach of children and pets.
- Disassembly, repair or remodeling by an unauthorized person may result in serious harm and will void the manufactures warranty.
- Always place this humidifier on a firm, flat & level surface. This humidifier may not work properly on an uneven surface.
- Do not place this product on cloth, carpet or an absorbent surface. This may block air inlet.
- This product releases mist. Do not place this humidifier directly on wood furniture, flooring or any surfaces that could be damaged by water. Manufacturer does not accept any liability for damage in the case of the unit being placed incorrectly.
- Do not use if the plug is damaged or loose.
- Before filling or cleaning the unit, make sure it is unplugged.
- Once the humidifier has been plugged in, do not tilt or move the unit.
- Do not handle the plug with wet hands.
- Do not excessively bend, twist, pull or damage the power cord.
- Avoid placing this product where the humidity spout is pointed directly at an object or person.
- Do not inhale the mist/vapor expelled from the product or drink water from the tank.
- Do not fill the water tank with hot or boiling water.
- Do not use this product in direct sunlight or near a heat source such as a stove, heater or radiator.
- If the water tank becomes cracked or damaged, do not use.
- Do not keep this product running for an extended period of time.
- Unplug the cord when unit is not in use for an extended period of time and/or when no one is home.
- Do not keep water in the tank when not in use for an extended period of time.
- Do not clean the unit, water tank or water reservoir with detergents or chemicals of any kind.
- The use of water additives in the tank including ethereal/essential oils, fragrances, eucalyptus, water conditioners, etc. will damage the appliance materials and as a consequence the whole unit. Any use of such additives in the tank will void the manufactures warranty.
- Do not use this product near any other electronic device.
- Do not cover the spray spout at any time during use. Do not put anything on or in the tank.
- IMPORTANT: Neither humans nor animals can hear the high frequency vibrations.
- When unplugging from outlet hold humidifier securely.
- Do not place cord over objects.
- Do not get water in or on the power cord or where it connects to the product.
- Do not use near a sink.
- Do not touch the water tank during operation.
- Do not submerse the unit in water or pour water on the unit or in the humidity spout.
- When emptying water from water tank, pour on drain side.
- Do not cover the spout with cloth or hand and do not use without the spout.
- Use clean or distilled water in tank. Hard water areas will require more frequent cleaning.
Stop using your humidifier and contact your physician if you have respiratory symptoms which you believe are associated with periods of use of your home humidifier, even if you are following maintenance directions.
WARNING: Cancer and Reproductive Harm. For more information go to www.P65Warnings.ca.gov. This equipment has been tested and found to comply with the limits for a Consumer ISM equipment, pursuant to Part 18 of the FCC Rules. Although tested, it may affect these devices. If the humidifier is found to interfere, separate the device and/or the humidifier. Conduct only the user maintenance found in this manual. Other maintenance and servicing can cause harmful interference and can void the required FCC compliance.
SPECIFICATIONS
- HUMIDIFYING MODE: Ultrasonic Cool Mist
- TANK CAPACITY: 1.0 gallons
- SUCCESSIVE HUMIDITY HOURS: Up to approximately 70 hours between tank refills when on lowest mist setting.
**PARTS
**
DIRECTIONS FOR USE
SET UP
Select a firm, level, flat location – at least six inches (15 cm) from any
wall or object for proper air flow. Place the humidifier on a water-resistant
surface, as water can damage furniture and some flooring. Do not place unit
directly on carpet, towels, blankets or other absorbent surfaces.
Guardian Technologies will not accept responsibility for damage caused by
water spillage.
FILLING –
Make sure unit is unplugged.
-
Separate the tank from the base of the unit.
-
Flip over water tank and open the tank lid, turning it to the left.
-
Pour cool, clean water directly into the tank. Do not pour anything but water into the tank.
-
Close the tank lid, turning it to the right. It is important to FIRMLY secure cap after filling the tank with water.
-
Attach the tank to the base of the unit by aligning night light (in base) with night light cap (in tank). Plug in.
-
Add a few drops of your favorite essential oil to the pad in the tray. (Oil not included)
WARNING: DO NOT add oils or other additives directly into the water tank. Add only to the pad in the tray. Oils added to the tank will damage the tank and the whole unit. Any use of such additives in the tank will void the manufacturer’s warranty. Pureguardian essential oils and replacement pads sold separately at www.guardiantechnologies.com -
Before turning on make sure there is water in the unit. Press the Power Button.
Are minerals in your water producing white dust?
Try Decalcification Cartridge FLTDC30 Look for cartridge at your local
retailer or visit
www.guardiantechnologies.com
NOTE : If you live in a hard-water area, we recommend the use of
distilled water for your humidifier. This will help reduce the precipitation
of minerals or ‘white dust’.
CLEANING
-
Always unplug the unit before servicing in any way.
GENERAL CLEANING -
Water tank. Empty water tank. Remove mist spout and clean with fresh water and a light brush (bottle cleaning brush is recommended).
-
Outer surface of the unit. Wipe the surface of the unit with a soft, damp cloth if needed. If you notice an accumulation of water during usage, reduce humidity and dry outer surface with a cloth.
DESCALING
- Depending on usage and water type, cleaning to remove scale may be required weekly or every other week to optimize unit performance.
- If you live in a hard water area, we recommend the use of distilled water for your humidifier. This will help reduce the precipitation of minerals or ‘white dust’.
- Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.
ULTRASONIC DISK
- Unplug unit.
- Remove the tank and empty all water from unit base and tank.
- Locate the ultrasonic disk on the inside center of the base unit.
- Use ONLY the enclosed cleaning brush to gently clean disk and remove build up and deposits. Do not scrub or scrape the ultrasonic disk.
If scale becomes difficult to remove with a brush:
- Fill the Base with: mixture of 1 tsp. white vinegar and 1 tsp. water.
- Let the solution stand for 5 minutes.
- With the vinegar in the Base, clean all interior surfaces with a soft cloth or brush to help remove scale.
- Also, check the mist nozzle and mist tube in the water tank. Clean as needed.
- Rinse the Base thoroughly with water to remove scale and vinegar solution.
END OF SEASON STORAGE
- Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end of the season.
- Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
- Pack the unit in its original carton and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.
TROUBLESHOOTING GUIDE
PROBLEM | SOLUTION |
---|---|
Water vapor and humidity are not produced. | Power Plug: Unplug and then try |
again.
Power Failure: When the power is returned, try again. Tank Installation: Make sure the tank is correctly attached.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
Air blows but water vapor is not produced.| Excessive Water: Remove a certain amount of water from the tank.
The desired humidity is lower than the current temperature: Increase the desired humidity.
Detergent residue and/or oil ingredients from cosmetics, etc. may be in tank; wash out the tank and try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk. If you use hard water, replace with softer water.
The humidity level is low.| The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
The water in the unit is too cold: Replace with cool, but not cold water. Damage on the ultrasonic disk: Contact Customer Service
The humidity has a bad smell.| Poor maintenance or dirty water: Clean the
product thoroughly, and fill it with fresh water.
White dust is forming on nearby furniture.| Hard water may deposit a certain
amount of dust. Dust in the air also settles because of added humidity in the
room. Use distilled water if this becomes a nuisance.
Unit has stopped working.| No or low water. Unplug the unit and refill tank.
Water is accumulating outside of unit or area surrounding unit.| Saturation of
humidity. Lower mist control setting.
The unit not level and water is accumulating. Unplug and place on a level surface. Point spray away from objects. Raise unit on a water-resistant level surface 2-3 feet off of floor.
Increased noise level.| Unit must be placed on a flat, level, hard surface.
Make sure it is NOT placed on a soft or absorbent surface.
Water dripping when refilling.| Water remaining on the bottom of tank. Wipe
tank or tilt to drain before transporting.
Cannot smell aroma scent.| Add a few more drops of oil to the aroma pad.
Replace the aroma pad with a new one.
LIMITED WARRANTY
To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. In order to be eligible for this Limited Warranty, an original sales receipt or comparable substitute proof of purchase bearing the date of original purchase is required. Refer to the original product carton or specific product/model page on the Guardian Technologies website for warranty length for your particular model. This warranty applies only to the original purchaser of this product from the original date of purchase. This warranty covers product purchased from authorized distributors only. This warranty applies to repair or replacement of product found to be defective in materials or workmanship. This warranty does not apply to damage resulting from unusual wear, commercial, abusive, unreasonable use or supplemental damage.
This warranty does not cover damage from unauthorized repairs or from any use not in accordance with the instruction manual. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. All warranty repairs must be completed by Guardian Technologies LLC. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A.) To submit product under warranty the complete machine must be delivered pre-paid to Guardian Technologies LLC. Please include complete information including: the problem, the model number of the product, the day of purchase, and a copy of the original sales receipt along with your name, address, and telephone (email optional). Address returns to the attention of: Customer Service, at the address below. Additional questions or comments can be made toll free to the number listed below.
USA and Canada
Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Please go to www.guardiantechnologies.com to register your product. We consider the registration process important to ensuring superior service to our customers, however submitting the registration is optional and does not affect your rights to utilize this warranty according to the conditions stated above. Additional copies of the instruction manual can be obtained by accessing and printing directly from our website or calling customer service.
Guardian Technologies LLC
26251 Bluestone Blvd. • Euclid, OH 44132
1.866.603.5900 •
www.guardiantechnologies.com
References
- Lasko, GermGuardian, B-Air, BlueDri | Fans, Heaters, Air Purifiers – GuardianTechnologies
- P65Warnings.ca.gov