guardian TECHNOLOGIES SD495 Wall Mount Soap and Sanitizer Dispenser Instructions
- June 6, 2024
- guardian technologies
Table of Contents
- guardian TECHNOLOGIES SD495 Wall Mount Soap and Sanitizer Dispenser
- PRODUCT SPECIFICATIONS AND PARTS
- Dispenser Installation
- Battery Installation
- Installation of the Refill Bottle and Pump
- Product Usage
- TROUBLESHOOTING GUIDE
- LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
guardian TECHNOLOGIES SD495 Wall Mount Soap and Sanitizer Dispenser
WARNINGS
Failure to comply with the warnings listed below may result in electric shock
or serious injury. This product should be used only in accordance with the
specifications outlined in this manual. Usage other than what has been
specified here may result in serious injury. When using electrical appliances,
basic precautions should always be followed to reduce the risk of fire,
electric shock and injury to persons, including the following:
- Always use the designated spout for liquid, foam or gel soaps/sanitizers.
- Use caution when using hand sanitizers that contain flammable ingredients.
Read and follow soap/sanitizer manufacturer instructions before use.
- For normal “automatic dispensing,” do not mix water with liquid soap, sanitizer or lotion.
- Do not rinse, submerge, or allow liquid to enter the battery compartment.
- Do not immerse the unit in water to avoid the malfunction of the inner electrical parts of the unit.
- Do not expose the unit directly to strong sunlight otherwise it will cause the malfunction of the infrared sensor.
- Do not allow to be used as a toy. Close attention is necessary when used by or near children.
- If appliance is not working as it should, has been dropped, damaged, left outdoors or dropped in water, call Customer Service.
- Remove batteries before any routine cleaning or maintenance.
- Leaks from battery cells can occur under extreme conditions. If the liquid gets on the skin (1) wash quickly with soap and water or (2) neutralize with a mild acid such as lemon juice or vinegar. If the liquid gets into the eyes, flush them immediatelywith clean water for a minimum of 10 minutes. Seek medical attention.
- Use only 4 AA batteries (4).
WARNING : Cancer or Reproductive Harm. For more information go to www.P65Warnings.ca.gov.
PRODUCT SPECIFICATIONS AND PARTS
Dispenser Installation
The automatic soap dispenser must be installed at least 8” away from other furniture.
- Insert the anti-theft key in the keyhole at the top of the dispenser, grip the top of the back of the dispenser while holding the top of the cover by hand, and open it gently downward. The cover will be on the bottom of the dispenser (see figure 1).
- Remove the liner refill bottle and pump head by sliding it out. Remove the battery compartment by pressing the two tabs above the compartment and slide the whole assembly upward to release (see figure 2).
- There are 2 options for installing wall anchors (see figure 3). After choosing wall anchor installation, place the dispenser on the wall where you want to install dispenser.
- Mark the wall anchor locations and drill a hole for each wall anchor (4-6 mm). Insert the anchor into the wall. Align the dispenser (check to make sure it is facing the right direction and open cover is at the bottom of the dispenser) and secure with screws (see figure 4).
- Replace the liner refill bottle, pump head and battery compartment.
Battery Installation
Open the soap dispenser. The battery holder is on the right side facing the soap dispenser. Note the arrow on the cover and slide the cover forward to remove. Insert four (4) AA batteries as shown (see figure 5). Return the battery cover by sliding it back over the side of the compartment.
Adding Soap or Sanitizer
- Remove the soap dispenser refill bottle and pump from the dispenser.
- Select the proper pump for the type of soap or sanitizer being added. See chart below: Note: if switching the type of soap/sanitizer, be sure the refill bottle is completely empty.
- First install selected pump by sliding it into refill bottle opening at the bottom of the bottle. It will be a snug fit (see figure 6).
- After the correct pump is installed, open the cap of the refill bottle and pour in the soap or sanitizer. The bottle will hold up to 1000ml. Return and secure cap.
- Use the window to see when it’s time to refill the liquid in the bottle.
Note: Clean the nozzle periodically to remove soap or sanitizer build up, especially if a gel solution is used. This will prevent the nozzle head from blocked and not working.
Installation of the Refill Bottle and Pump
-
Return the refill bottle to the dispenser. The refill bottle markings should face outward to be lined up correctly.
-
Gently slide the refill bottle and pump head into the dispenser, it will sit on top of the battery compartment. The pump will fit within the battery compartment grooves. Make sure the push rod engages in the empty position 1 on top of the discharge nozzle of the pump (see figure 7).
-
You can select a single or double dispensing cycle. To select single or double dispensing cycle you press the black pumping cycle button (see figure 7).
Tip: A double dispensing may be preferred with a thick gel or foam soap. Light will flash 3 times for single cycle dispensing. Light will flash twice rapidly 3 times for double cycle dispensing. -
Close and lock dispenser cover.
Product Usage
- The indicator light on the front of the dispenser will be green when it’s ready to use.
- Place hands under the dispenser to activate the infrared sensor.
- The light turns red when the batteries are low or the sensor is still activated by a hand or object, even though the cycle is complete.
TROUBLESHOOTING GUIDE
PROBLEM | SOLUTION |
---|---|
Unit won’t power on. | Make sure batteries are inserted properly. Replace with |
new batteries.
Too much/too little soap is being dispensed.| Adjust the liquid volume (see
filling instructions).
No liquid is being dispensed.| Make sure batteries are working properly.
Confirm dispenser is connected and in the liquid. Refill soap.
Remove any soap build up from pump.
Unit turns off.| Make sure batteries are working properly.
Indicator light is Red.| Batteries are low.
The unit sensor is still activated by a hand or object, even though the cycle is complete. Remove hand/object.
LIMITED WARRANTY
To the consumer, Guardian Technologies LLC warrants this product to be free of
defects in materials or workmanship commencing upon the date of the original
purchase. In order to be eligible for this Limited Warranty, an original sales
receipt or comparable substitute proof of purchase bearing the date of
original purchase is required. Refer to the original product carton or
specific product/model page on the Guardian Technologies website for warranty
length for your particular model. This warranty applies only to the original
purchaser of this product from the original date of purchase. This warranty
covers products purchased from authorized distributors only. This warranty
does not cover Guardian Technologies products that are used outside of the US
and Canada as the appliance must be plugged directly into a 120V AC electrical
outlet without the use of an adapter. This warranty applies to the repair or
replacement of products found to be defective in materials or workmanship.
This warranty does not apply to damage resulting from unusual wear,
commercial, abusive, unreasonable use or supplemental damage. This warranty
does not cover damage from unauthorized repairs or from any use not in
accordance with the instruction manual. Defects that are the result of normal
wear and tear will not be considered manufacturing defects under this
warranty. If this product should become defective within the warranty period,
we will repair or replace any defective parts free of charge. All warranty
repairs must be completed by Guardian Technologies LLC. This warranty gives
you specific legal rights and you may also have other rights (other rights may
vary from state to state in the U.S.A.) To submit the product under warranty
the complete machine must be delivered pre-paid to Guardian Technologies LLC.
Please include complete information including the problem, the model number of
the product, the day of purchase, and a copy of the original sales receipt
along with your name, address, and telephone (email optional). Address returns
to the attention of Customer Service, at the address below. Additional
questions or comments can be made toll-free to the number listed below.
USA and Canada
Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Please go to
www.guardiantechnologies.com to
register your product. We consider the registration process important to
ensuring superior service to our customers, however, submitting the
registration is optional and does not affect your rights to utilize this
warranty according to the conditions stated above. Additional copies of the
instruction manual can be obtained by accessing and printing directly from our
website or calling customer service.
Guardian Technologies LLC
26251 Bluestone Blvd. • Euclid, OH 44132
1.866.603.5900 •
www.guardiantechnologies.com
References
- Lasko, GermGuardian, B-Air, BlueDri | Fans, Heaters, Air Purifiers – GuardianTechnologies
- P65Warnings.ca.gov
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>