FISHER PAYKEL 900PT561 Tube and Chamber Kit Instruction Manual

June 6, 2024
Fisher & Paykel

**FISHER PAYKEL 900PT561 Tube and Chamber Kit Instruction Manual

**

Indications for Use

Heated breathing tube for delivery of humidified respiratory gases.
For use with AIRVO™ and AIRVO™ 2 Series humidifiers in hospitals and long-term care facilities.
For use at flows from 2 to 60 L/min depending on the patient interface.
Compatible patient interfaces: nasal cannula, tracheostomy direct connection, mask adapter.

System Specifications

Circuit Length: 1.8 m (6 ft) + interface

Setup

  • AIRVO/AIRVO 2/myAIRVO™/myAIRVO 2 humidifier (“AIRVO”) on a flat surface.

  • OPT316/OPT318/OPT942/OPT942E/OPT944/OPT944E/
    OPT946/OPT946E/OPT970/OPT970E/OPT980/OPT980E/
    OPT1042/OPT1044/OPT1046 patient interface (OPT104x may not be available in all countries).

  • Use only USP sterile/distilled water for inhalation, or equivalent.

  • This product is not intended for use with any medication.
    Warning: Use of a non-approved accessory could impair performance or compromise safety.

Hospital Use

  • This product is intended to be used for a maximum of 14 days.
  • Do not soak, wash or sterilize.

Home Use

  • This product is intended to be used for a maximum of 60 days for home use, provided that the myAIRVO/myAIRVO 2 cleaning and maintenance instructions are followed.
Steps 1 – 7

Assemble and connect water chamber.

Step 8

Ensure water level is rising but not going over the maximum water level.

Step 9

Connect breathing tube to AIRVO.

Step 10

Make sure blue connector is fully located into place.

Step 11

Connect breathing tube to patient interface once the system has warmed up. Position breathing tube below patient interface so that condensate flows away from the patient.

Step 12

Connect breathing tube clip to patient clothing or bedding.
Note: connecting to patient clothing may not be suitable for all patient groups.

Using Instructions
Using InstructionsUsing
Instructions

Incorrect water level
Replace MR290 chamber

Correct water level in the
MR290 chamber

WARNINGS

  • For single patient use only. Reuse may result in transmission of infectious substances. Attempting to reprocess will result in degradation of materials and render the product defective.
  • Using the breathing tube for longer than the specified time can result in serious injury including infection.
  • Do not use the auto-fill MR290 chamber if it has been dropped or been allowed to run dry as this could lead to the chamber over-filling.
  • Do not use the MR290 chamber if the water level rises above the maximum water level line as this may lead to water entering the patient’s airway.
  • Never operate the unit if the breathing tube has been damaged with holes, tears or kinks.
  • Do not block the flow of air through the unit and breathing tube.
  • California residents please be advised of the following, pursuant to Proposition 65: This product contains chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. For more information, please visit: www.fphcare.com/prop65

To avoid burns:

  • Do not allow the breathing tube to remain in direct contact with skin for prolonged periods of time.
  • Do not use in the presence of a naked flame, to avoid fires.
  • Do not add heat to any part of the breathing tube e.g. covering with a blanket, or heating it in an incubator or overhead heater for a neonate, as this could result in serious injury

Cautions

  • Avoid contact with chemicals, cleaning agents, or hand sanitizers.
  • Use only USP sterile/distilled water for inhalation, or equivalent.

To prevent condensation:

  • Use in a room warmer than 18 °C (64 °F).
  • Remove/minimize the impact of anything that may cool the heated breathing tube, e.g. a fan, air conditioning, open window.

To manage excessive condensation:

  • Place the AIRVO below patient head height.
  • Drain condensate back into the water chamber.
  • At higher target flow settings it may be necessary to first reduce the target flow setting to 30 L/min, to ensure that the condensate drains safely and effectively.
  • Disconnect the patient interface from the heated breathing tube.
  • Lift the patient end of the heated breathing tube, allowing the condensate to run into the water chamber.

Icons F & P, AIRVO and myAIRVO are trademarks of Fisher & Paykel Healthcare Ltd.
For patent information, see www.fphcare.com/ip

Manufacturer

Fisher & Paykel Healthcare Ltd,
15 Maurice Paykel Place,
East Tamaki, Auckland 2013,
PO Box 14 348 Panmure,
Auckland 1741,
New Zealand
Tel: +64 9 574 0100
Fax: +64 9 574 0158
Email: info@fphcare.co.nz
Web: www.fphcare.com
Importer/Distributor Australia (Sponsor) Fisher & Paykel Healthcare Pty Ltd, 19-31 King Street, Nunawading,
Melbourne, Victoria 3131.
Tel: +61 3 9871 4900
Fax: +61 3 9871 4998
Austria Tel: 0800 29 31 23
Fax: 0800 29 31 22
Benelux Tel: +31 40 216 3555
Fax: +31 40 216 3554
Brazil Fisher & Paykel do Brasil,
Rua Sampaio Viana, 277 cj 21, Paraíso,
04004-000, São Paulo – SP,
Brazil Tel: +55 11 2548 7002
China 代理人/售后服务机构:费雪派克医疗保健(广州)有限公司, 广州高新技术产业开发区科学城科丰路31号G12栋301号 电话:
+86 20 32053486
传真: +86 20 32052132
Denmark
Tel: +45 70 26 37 70
Fax: +46 83 66 310
Finland
Tel: +358 94 1590 355
Fax: +46 83 66 310
France Fisher & Paykel Healthcare SAS,
10 Av. du Québec,
Bât F5, BP 512,
Villebon-sur-Yvette,
91946 Courtaboeuf Cedex,

France
Tel: +33 1 6446 5201
Fax: +33 1 6446 5221
Email: c.s@fphcare.fr

Germany Fisher & Paykel Healthcare GmbH & Co. KG,
Deutschland,
Österreich,
Schweiz,
Wiesenstrasse 49,
D 73614 Schorndorf,

Germany

Tel: +49 7181 98599 0
Fax: +49 7181 98599 66

Hong Kong
Tel: +852 2116 0032
Fax: +852 2116 0085

India
Tel: +91 80 2309 6400
Ireland
Tel: 1800 409 011
Fax: +44 1628 626 146

Italy
Tel: +39 06 7839 2939
Fax: +39 06 7814 7709

Japan
Tel: +81 3 5117 7110
Fax: +81 3 5117 7115

Korea
Tel: +82 2 6205 6900
Fax: +82 2 6309 6901

Norway
Tel: +47 21 60 13 53
Fax: +47 22 99 60 10

Russia
Tel. and Fax: +7 495 782 21 50

Spain
Tel: +34 902 013 346
Fax: +34 902 013 379

Sweden
Tel: +46 8 564 76 680
Fax: +46 8 36 63 10

Switzerland
Tel: 0800 83 47 63
Fax: 0800 83 47 54

Taiwan
Tel: +886 2 8751 1739
Fax: +886 2 8751 5625

Turkey İthalatçı Firma:
Fisher Paykel Sağlık Ürünleri Ticaret Limited Şirketi, İletişim Bilgileri:
Ostim Mahallesi 1249. Cadde No:6, Yenimahalle, Ankara,
Türkiye 06374,
Tel: +90 312 354 34 12
Fax: +90 312 354 31 01

UK Fisher & Paykel Healthcare Ltd, Unit 16,
Cordwallis Park, Clivemont Road, Maidenhead,
Berkshire SL6 7BU,

UK
Tel: 0800 132 189
Fax: +44 1628 626 146

USA/Canada
Tel: 1800 446 3908 or +1 949 453 4000
Fax: +1 949 453 4001

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Fisher & Paykel User Manuals

Related Manuals