Thundercomm TurboX EB5 Edge AI Box User Manual

June 6, 2024
Thundercomm

TurboX EB5 Edge AI Box
User ManualThundercomm TurboX EB5 Edge AI Box Rev. V1.5
June 28, 2021

Revision History

Revision Date Description
1.0 Jan 25, 2021 Initial release
1. May 25, 2021 Update the pictures of the figure
1. June 7, 2021 Update some points
1. June 8, 2021 Update some points
1. June 22, 2021 Change description of Phoenix terminal
2. June 28, 2021 Update certification-related information.

About This Document

  • Illustrations in this documentation might look different from your product.
  • Depending on the model, some optional accessories, features, and software programs might not be available on your device.
  • Depending on the version of operating systems and programs, some user interface instructions might not be applicable to your device.
  • Documentation content is subject to change without notice. Thundercomm makes constant improvements on the documentation of your computer, including this guidebook.
  • Button, tool, and key names appear in bold font, for example, click Save or press Enter.
  • Folders and files are formatted in italic, for example, turbox_flash_flat.sh.

Chapter 1. Safety and Warranty

Read this chapter first before installing, operating, or maintaining equipment developed by Thundercomm.
General safety precautions

  • To ensure the safety of person and equipment, follow all the safety precautions on the device identification and in this manual when installing, operating, and maintaining equipment.
  • Notes, warnings, and hazards in the manual do not represent all safety matters that should be observed. It is intended only as a supplement to all safety considerations.

Local laws and regulations
When you operate the device, please comply with local laws and regulations. Safety precautions in this manual are intended only as a supplement to local safety regulations.

Basic installation requirements
The person responsible for installing and maintaining Thundercomm equipment must first be trained strictly and know all kinds of safety precautions. He must also master the correct operating methods before he can install, operate, and maintain the equipment.

  • Only qualified and trained personnel are allowed to install, operate and maintain the equipment.
  • Only qualified professionals are allowed to remove safety facilities and repair equipment.
  • Replacing and changing equipment or parts, including software, must be done by a person certified or authorized by Thundercomm.
  • The operator shall promptly report to the person in charge any failure or error that may cause a safety problem.

Grounding requirements
The following requirements apply only to equipment requiring grounding:

  • When installing equipment, it is necessary to first ground; When removing the equipment, remove the ground wire last.
  • Do not destroy the ground conductor.
  • Do not operate equipment without a grounded conductor installed.
  • The equipment shall be permanently attached to the protected area. Check electrical connections before operating equipment. Please ensure that the equipment is reliably grounded.

On operator

  • Do not operate equipment and cables during thunderstorms.

  • When thunderstorm weather, you should unplug the AC power connector, prohibit the use of fixed terminals, do not touch the terminal and antenna connector.
    Instructions: The above two requirements apply to wireless fixed station terminals.

  • To avoid shock hazards, do not connect safety extra-low voltage (SELV) circuit terminals to communication network voltage (TNV) circuit terminals.

  • It is forbidden to look directly at the fiber outlet with an open eye to prevent the laser beam from burning the eye.

  • Before operating the equipment, you should wear anti-static work clothes and anti-static gloves or wristbands.
    Remove conductive objects such as jewelry and watches to avoid being shocked or burned.

  • If there is a fire, you should evacuate the building or equipment area and press the fire alarm bell, or call the fire alarm number. No re-entry into the burning building is allowed under any circumstances.

On equipment

  • Before the operation, the equipment should be reliably fixed on the floor or other stable objects, such as walls or mounting frames.
  • Do not block the vent when the system is running.
  • When installing the panel, if the screws need to be tightened, you must use tools.
  • After installing the equipment, please clear the empty packing materials in the equipment area.

Marks on equipment
Refer to the table below to comprehend safety signs.

Table 1-1.Safety sign list

Graphic Name Instructions
Warning signs The logo indicates that improper operation may result in

equipment damage or personal injury.
| External ground marking| This mark is the grounding mark outside the equipment. The two ends of the grounding cable are connected to different equipment, which means that the equipment must be earthed at the connecting point, so as to ensure the normal operation of the equipment and the personal safety of operators.
| Internal ground mark| This mark is the grounding mark inside the equipment. Both ends of the grounding cable are connected to different components of the same equipment, which means that the equipment must be grounded through the connecting point to ensure the normal operation of the equipment and the personal safety of operators.
| Antistatic mark| This mark indicates an electrostatic-sensitive area. Do not touch the device with your bare hands. When operating in this area, take strict anti-static measures, such as wearing anti-static wrist bands or anti- static gloves.

Electrical safety

  • High Pressure

Notice:

  • A high voltage power supply provides power for the operation of equipment. Direct contact with a high voltage power supply or indirect contact with a high voltage power supply through a wet object will bring fatal danger.
  • Improper and incorrect operation of high voltage may cause accidents such as fire or electric shock.

Thunderstorm Weather
This requirement applies only to wireless base stations or devices with skylines.
Notice: It is forbidden to operate the tower and mast under thunderstorms, otherwise there will be danger of life.

Big Leakage Current
Notice:

  • The equipment must be grounded before the power is switched on, otherwise, it will endanger the safety of the person and equipment.
  • If there is a “large leakage current” sign posted near the power terminal of the equipment, the protective grounding terminal of the equipment housing must be grounded  before connecting the AC input power to prevent the leakage current of the equipment from causing electric shock to the human body.

Power Cord
Notice:

  • Do not install or remove the power cord live. The moment the power core touches the conductor, it will produce an electric arc or spark, which can lead to fire or eye injury.
  • The power switch must be turned off before the power cord is installed or removed.
  • Before connecting the power cord, make sure that the power cord label is correctly identified before connecting.

Fuse
Notice: To ensure the safe operation of the equipment, when the fuse on the equipment is blown, the fuse of the same model and specification should be replaced.

Electrostatic Discharge
Notice:

  • Static electricity generated by the human body will damage electrostatic-sensitive components on the single board, such as large-scale integrated circuits (LSI) and so on.
  • In the case of human body movement, clothing friction, shoes and floor friction or holding ordinary plastic products, the human body will generate an electrostatic electromagnetic field, not easy to disappear before discharge.
  • Before touching the equipment and holding the single board or special integrated circuit (ASIC) chip, the anti-static wrist band must be worn and the other end of the anti-static wrist band must be well grounded to prevent the body’s electrostatic damage to sensitive components.

Anti-static wristband:Thundercomm TurboX EB5 Edge AI Box - figure
1

Safety and caution information

AC Power Adapter: Risk of electric shock, fire, or burn if using an AC adapter other than the one provided with this device, Indoor use only and in dry locations.
The device must only be repaired by a professional, do not open the enclosure.
The rated parameter of the adapter is 19v / 6.32a, 120W, please use the socket with grounding wire.

  • Risk of explosion if the battery is replaced with an incorrect type. Batteries should be recycled where possible.
    Disposal of used batteries must be in accordance with local environmental regulations.

  • Failure to use the included power adapter shall violate regulatory compliance requirements and may expose the user to safety hazards.

Medical: This device may interfere with the operation of some pacemakers, hearing aids or other medical devices.
To reduce the risk, maintain a separation distanceof20cm(8inches) between the device and the medical device.
Refer to the medical device for additional information.
Modify: Modification of the wireless solution, thermal solution, device components or enclosure shall violate regulatory compliance requirements and may induce safety hazards.

Chapter 2. Introduction

Overview
EB5 Edge AI box is a lightweight edge device, featuring powerful AI and video decode capabilities. It supports device edge-cloud synergy, remote algorithm and application deployment, FOTA, and DM. It can be widely used in complex environments such as industrial parks, urban residential areas, and shopping malls.
EB5 is a Thundercomm lightweight edge device for a wide range of edge applications, featuring strong AI computing performance, flexible configuration, wide temperature range  support, environmental adaptability, and easy maintenance and management. EB5 is mainly used as an edge gateway and edge intelligent analysis device to deploy in various  edge application scenarios such as smart building, smart cars, and smart re.Thundercomm
TurboX EB5 Edge AI Box - figure 2

Note: The manual is a generic version, this product does not have a 5G NR band.

Key features

Easy to use for edge scenes

  • Real-time: EB5 can deal with the data locally and provide real-time responses.
  • Low bandwidth: EB5 can only transfer necessary information to the cloud.
  • Privacy protection: you can decide to save your information either to the cloud or to local directories. All information sent to the cloud can be encrypted.
  • Support standard containers engine.
  • Support rapid deployment of third-party algorithms and applications (under development).

24-channel video analysis (under development)

  • Support 24-channel 1080p@30FPS decoding.
  • Support 16-channel 1080p@30FPS coding.

Strong environmental adaptability (Support for edge environment deployment)

  • Industrial protection grade: IP40 Level design.

Flexible Ethernet connection selection (under development)

  • Support optional 5G module.

High reliability

  • All firmware in the system supports cluster backup. (under development)
  • Support software and hardware fault detection and Alarm. (under development)
  • Provide cluster backup solution, built-in cluster backup software. (under development)

Remote maintenance and upgrade

  • Remote view of IP cameras surveillance video screen connected to EB5.
  • Configure the camera parameters of IP cameras remotely.
  • Remote firmware upgrade for EB5.

Usage scenario
EB5 can be used in many scenarios, including safe city, smart safety supervision, smart transportation, smart manufacturing, smart retail, smart care, etc. Typical architectures in  these application scenarios are as follows:

  • Terminal: Wirelessly connect to IPC (IP Camera) or other front-end devices.
  • Edge: Edge implements value information extraction, storage, and uploading.
  • Cloud: Datacenter model management, development, and application.

Thundercomm TurboX EB5 Edge AI Box - figure 3

Product specifications

Table 2-1.EB5 Specifications

Item Specifications
OS Ubuntu18.04

Platform
(SnapdragonTM QRB5165, Al Performance: 15 TOPS)| CPU: Qualcomm® KryoTM 585 CPU, CPU Clock Speed: up to 2.84GHz
GPU: Qualcomm® AdrenoTM 650 GP
DSP: Qualcomm® HexagonTM 698 Processor
VPU: AdrenoTM 665 VPU,
H264 & H265 codec support; video decoding: 8k@60fps; video encode: 8k@30fps
ISP: Qualcomm SpectraTM 480 image processing
System Memory| RAM: 8GB, LPDDRS(POP)
Storage| Flash: 128G UFS3.0 on board
Expansion: SD Card, SSD
Display| 2x HOW out, 1080p@60fps
USB| 4x USB 3.0 Type A, lx USB3.1 Type C(OTG)
Micro SD| lx Micro SD Slot
SIM| lx NanoSIM card slot
Ethernet| 2x Gigabit ethernet(10/100M/1000M)
COM Port| 2x RS232, 2x RS485
CAN| 2x CAN bus
DI/DO| 8 DI/D0(4 DI, 4 DO)
Wireless Connectivity| WIFI: 802.11a/b/g/n/ac/ax, 2×2 MIMO
5G: M.2 5G module(optional), multimode support:2G/3G/4G/5G NR sub-6

Antenna: 6x Antenna connector (2x for WIFI,4x for 5G)
Audio| lx MIC, lx Earphone
Debug Port| lx Micro USB (for debug)
Input & Indicators| Buttons: Power key, Reset key
LEDs: Power status, WIFI status,SG status
Others| CR2032 RTC Battery
DC input| 19V DC (can support 12v-24v DC)
Mechanical| Waterproof: IP40 Level Design
Dimension: 200mm
235.5mm44mm
Net weight: 2200g(box body only), 2638g(body and adaptor included)
Mount: Desktop, Wall Mount
Environment| Operation Temperature: -10-50 centigrade

Storage Temperature: -20-70 centigrade
Storage Humidity: 10%-90%, non-condensing
Anti-Vibration: 0.5Grms @ 5 — 500 Hz, random
Certification| CE, FCC**, JATE/Telec, RoHS/Reach

Note:
*: Test under typical application.
The manual is a generic version, this product does not have a 5G NR band.
**: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try  to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To maintain compliance with FCC’s RF exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body: Use only the supplied antenna.

RF Exposure Information(RED)
To maintain compliance with CE’s RF Exposure guidelines, This equipment should be installed and operated with a minimum distance of 20cm from the radiator of your body:  Use only the supplied antenna.
The band 5150-5350 MHz for this device is restricted to indoor use only within all European Union countries.
Hereby,[Thundercomm Technology Co., Ltd] declares that the radio equipment type [EB5] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
www.thundercomm.com.

Max EIRP for EU
2.4G Wifi: 19.71dBm
5G Wifi: 20.42dBm
5.8G Wifi: 13.47dBm

Appendix 1. Notices

A thunderstorm may have patents or pending patent programs covering the subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries to [email protected].
THUNDERCOMM PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT  NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimers of express or implied warranties in certain transactions; therefore, this statement may not apply to you.
Changes are made periodically to the information herein; these changes will be incorporated in new editions of the publication. To provide better service, Thundercomm reserves the right to improve and/or modify the products and software programs described in the manuals, and the content of the manual, at any time without additional notice.
The software interface and function and hardware configuration described in the manuals included with your development board or system on module might not match exactly the actual configuration of that you have purchased.
For the configuration of the product, refer to the related contract (if any) or product packing list, or consult the distributor for the product sales. Thunderstorm may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons.  The information contained in this document does not affect or change Thundercomm product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Thundercomm or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary.
The information in this document should not be an invitation for an offer or any advice to the visitors. Please consult the professional comments from the sales consultant prior to doing any actions of investment or purchase.
A thunderstorm may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Any references in this publication to non-Thundercomm Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites.  The materials at those Web sites are not part of the materials for this Thundercomm product, and use of those Web sites is at your own risk. Thundercomm shall not be responsible for the content of the third party.
Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly.  Some measurements may have been made on development- level systems and there is no guarantee that these measurements will be the same on generally available systems.
Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.
This document is copyrighted by Thundercomm and the property right of the date mentioned in this document, including but not limited to trademarks, patents, copyrights, trade names, etc. are not covered by any open-source license.
A thunderstorm may update this document at any time without notice.
Anyone doesn’t have the right to amend, reprint, republication, reproduce, transmit, distribute or any other way to use this document in business or public purpose without the prior written consent of Thundercomm.
E-mail messages sent to Thundercomm via the Internet are not guaranteed to be completely secure. Thundercomm shall not be liable for any loss incurred by the surfer when transmitting any information over the Internet or for any loss incurred by Thundercomm when sending any information over the Internet at your request.
A thunderstorm has all rights under other relevant exemptions provided by laws and regulations, and Thundercomm’s failure to claim or delay in claiming such rights shall not be deemed to be a waiver of such rights by Thundercomm.
Thundercomm reserves the right of final interpretation of this document.

Appendix 2. Trademarks

Thunderstorm, Thundercomm Turbox, and TURBO X are trademarks of Thundercomm Corporation or its associate companies in China and/or other countries. Intel, Intel  SpeedStep, Optane, and Thunderbolt are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries. Microsoft, Windows, Direct3D, BitLocker, and  Cortana are trademarks of the Microsoft group of companies. Mini DisplayPort (MDP), DisplayPort, and VESA are trademarks of the Video Electronics Standards Association.  The terms HDMI and HDMI High- Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing LLC in the United States and other countries.  Wi-Fi, Wi-Fi Alliance, WiGig, and Miracast are registered trademarks of Wi-Fi Alliance. USB-C is a registered trademark of the USB Implementers Forum. All other trademarks are the property of their respective owners.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Thundercomm User Manuals

Related Manuals