Access Control Outdoor IP68 Weatherproof Card Reader / Keypad Standalone No Software Wiegand 26-37 Bits Delay and On/Off Toggle Mode 125KHz EM Cards 2,000 Users

Description

The device is a standalone access control and proximity card reader which supports EM & MF card types. It builds in STC microprocessor, with strong anti-interference ability, high security and reliability, powerful function, and convenient operation. It’s widely used in high-end buildings, residential communities, and other public places.

Features

  1. Ultra-low power consumption: Standby current is less than 30mA.
  2. Input & Output: WG26 or WG34 input and output.
  3. Searching Time: Less than 0.1s after reading the card.
  4. Backlight Keypad: Easy to operate at night.
  5.  Doorbell interface: Support external wired doorbells.
  6. Access ways: Card, Pin code, Card & Pin code.
  7.  Independent codes: Use codes without a related card.
  8. Change codes: Users can change codes by themselves
  9. Delete users by card No.: The lost card can be deleted by keyboard

Specification

  1.  Working Voltage: DC12V-24V
  2.  Standby Current: ≤30mA
  3. Card Reading Distance: 2~5cm (0.79~1.97in.)
  4. Capacity: 2000 Users
  5. Working Temperature: -40°C~60°C (-40°F~140°F)
  6. Working Humidity:10%~90%
  7. Lock output load:≤3A
  8. Door Relay time:0~99S (Adjustable)

Installation

Drill hole according to the size of the device and fix the back shell with the equipped screw. Thread the cable through the cable hole. Connect the wires according to your required function, and wrap the unused wires to avoid a short circuits. After connecting the wire, install the machine.VISIONIS
VIS-3008 Access Control Outdoor IP68 Waterproof Card Reader
1

Color ID Description
Green D0 Wiegand Input (Wiegand Output in Card Reader

Mode)

White| D1| Wiegand Input (Wiegand Output in Card Reader

Mode)

Yellow| OPEN| Exit Button input terminal
Red| +12V| 12V + DC regulated power input
Black| GND| 12V – DC regulated power input
Blue| NO| Relay normally-on terminal
Purple| COM| Relay public terminal
Orange| NC| Relay normally-off terminal
Pink| BELL_A| Doorbell button one terminal
Pink| BELL_B| Doorbell button to the other terminal

Wiring

Diagram Common Power SupplyVISIONIS VIS-3008 Access Control Outdoor IP68
Waterproof Card Reader 2.

Diagram Special Power SupplyVISIONIS VIS-3008 Access Control Outdoor IP68
Waterproof Card Reader 3

Diagram Reader ModeVISIONIS VIS-3008 Access Control Outdoor IP68
Waterproof Card Reader 4

Connection with Accessories: Doorbell and an Exit buttonVISIONIS VIS-3008
Access Control Outdoor IP68 Waterproof Card Reader 5

Connection with Accessories: Doorbell, Exit Button, and Wireless ReceiverVISIONIS VIS-3008 Access Control Outdoor IP68 Waterproof Card Reader
6

Connection with Accessories: Doorbell, Exit Button, and PIR

Connection with Access Control PanelVISIONIS VIS-3008 Access Control
Outdoor IP68 Waterproof Card Reader 8

Sound and Light Indication

Operate Status LED Light Color Buzzer
Standby Red
Keypad Beep
Operation Successful Green Beep
Operation Failed Beep-Beep-Beep
Entering Programming Red Flash Red Slowly Beep
Programmable Status Orange
Exit Programming Red Beep
Door Opening Green Beep

Advance Setting









1

| Add Users| Notes
---|---|---
Change the master code|   Master code   #   0 New code   #   New code #| Default factory master code is 999999.
Add card|
Master code # 1

Read card # … #

| Cards can be added continuously
Add card number| *    Master code    #   1

8 digits or 10 digits   #

| Card number can be added continuously
Add ID number+ card| * Master code # 1

ID number # Read card #

| Add user with specify ID number, easily find and delete.
Add ID number+ card number| *   Master code   #   1 ID number #

8 digits or 10 digits #

| Add user with specify ID number, easily find and delete.
Add PIN code| *   Master code   #   1 ID number #

8 digits or 10 digits #

| ID number is from 1-2000





2

| Delete Users| Notes
Delete card|    Master code    #    2 Read Card or  8 or 10 digits #| Cards can be deleted continuously
Delete ID number|

ID Number #

| When the card is broken or lost, you can delete the user by ID number


2

| Delete ALL users| * Master code 0000 #| #| 2| Delete ALL PIN code & card users except public PIN code
---|---|---|---|---|---





3

| Access Users| Notes
By card|   Master code #| #| 3 0| Only the card user could unlock the door, keypad is invalid
By card+PIN code|
  Master code #| #| 3 1| To enable this function, the user PIN code has to be changed.
By card or PIN code| *  Master code #| #| 3 2| Both card user and PIN user could unlock the door (factory default)


4

| Relay Output Delay Time| Notes
Door relay strike time| * Master code

0~99 #

| #| 4| Door opening time range: 0-99s Default 5s




5

| Standalone access control mode|   Master code #| #| 50| The door will be locked automatically after open the door normally
Relay toggle mode|
  Master code #| #| 51| The door will not be locked automatically. To lock the door, the user has to read the card or press the exit button.
Reader mode| * Master code

26/34 #

| #| 52| WG26/34 input and output


6

| Bind a code to a specific card| *  Master code  #  6 Read Card  4 digits code #| When using card+code to unlock the door
---|---|---|---


7

| Data backup output| * Master code #

7  0        #

| Send the data to external device
Data backup input| * Master code #

7  1        #

| The device will receive the data


8

| Add public code| *   Master code    #    9 4 digits code #| Only one public code is available.

Delete public code:

*   Master code    # 9 #


| Change the

code by user card

| | | Read card| New code| #|
Repeat new Code #
Change the code by ID number added|
ID number  #  Old code  #  New code  # Repeat New code #
| Reset to Factory Default| Power off, press the exit button continuously, power on, hearing beep sound twice, meanwhile, the indicator light turns orange, swipe the first card as for master add card, swipe the second card as for the master delete card, the master code has been reset to 999999, factory default settings are successful.

*Registered user data won’t be deleted when reset to factory default

Master Card Operation

Add Card

  • Read master add a card
  • Read the 1st user card
  • Read the 2nd user card
  • Read master add a card

Note: The master add card is used to add card users continuously and quickly. When you read the master add card for the first time, you will hear a short “BEEP” sound twice and the indicator light turns orange, which means you have entered into add user programming. When you read the master add card for the second time, you will hear a long “BEEP” sound once and the indicator light turns red, it means you have exited the add user programming.

Delete Card

  • Read master delete card
  • Read the 1st user card
  • Read the 2nd user card
  • Read master delete card

Note: The master delete card is used to delete card users continuously and quickly. When you read the master delete card for the first time, you will hear a short “BEEP” sound twice and the indicator light turns orange, it means you have entered into delete user programming. When you read the master delete card for the second time, you will hear a long “BEEP” sound once, the indicator light turns red, which means you have exited the delete user programming.

Data Backup Operation

Example: Backup the data of machine A to machine B The green wire and white wire of machine A connects with the green wire and white wire of machine B correspondingly, set B for receiving mode at first, then set A for sending mode, the indicator light turns green flash during the data backup, data backup is successful when the indicator light turns red.