euromex MZ.4600 Digital Macrozoom Microscope User Manual

September 11, 2024
euromex

euromex MZ.4600 Digital Macrozoom Microscope

General safety instructions

Intended use: a non-medical device
This device is intended for general observation of cells and tissues, with transmitted/reflected illumination and with the specimen fixed on a slide.

Dangers associated with the operation

  • Improper use could result in injury, malfunction or damage to property. It must be ensured that the operator informs every user of existing hazards
  • Danger of electrocution. Disconnect the power to the entire lighting system before installing, adding or changing any component
  • Not to be used in corrosive or explosive environments
  • Avoid direct exposure of eyes to the collimated light beam or direct light from the light guides or fibres
  • To avoid a hazard to children, account for all parts and keep all packing materials in a safe place.

Prevention of biological and infectious hazards
Infectious, bacterial or viral biohazard substances under observation may be a risk to the health of humans and other living organisms. Special precautions should be taken during in vitro medical procedures:

  • Biological hazards:
    keep a logbook of all the biological substances or pathogenic microorganisms that were under observation with the device and show it to everybody before they use the device or before they do some maintenance work on the device! Agents can be bacterial, spores, enveloped or non-enveloped virus particles, fungi or protozoa

  • Contamination hazard:

  • A sample that is properly enclosed with a cover glass never comes in direct contact with the device parts. In that case prevention of contamination lies in the handling of the slides; as long as the slides are decontaminated before use and are undamaged and treated normally, there is virtually zero risk of contamination

  • A sample that is mounted on a slide without cover glass, can come in contact with components of the device and may be a hazard to humans and/or the environment. Therefore, check the device and accessories on possible contaminations. Clean the device’s surfaces and its components as thoroughly as possible. Should you identify a possible contamination, inform the local responsible person in your organisation

  • Operators could be contaminated from other activities and cross-contaminate components of the device. Therefore, check the device and accessories on possible contaminations. Clean the device’s surfaces and its components as thoroughly as possible. Should you identify a possible contamination, inform the local responsible person in your organisation. it is recommended to wear sterile gloves when preparing the slides and handling the device in order to reduce contamination by the operator

  • Infection hazard: direct contact with the focusing knobs, stage adjustments, stage and eyepieces/tubes of the device can be a potential source of bacterial and/or viral infections. The risk can be limited by using personal eyeshades or eyepieces. You can also use personal protections such as operation gloves and/or safety goggles, which should be changed frequently to minimize the risk

  • Disinfectant hazards: before cleaning or disinfecting, check if the room is adequately ventilated. If not, wear respiratory protective gear. Exposure to chemicals and aerosols can harm human eyes, skin and respiratory system. Do not inhale vapours. During disinfection, do not eat, drink or smoke. Used disinfectants must be disposed of according to local or national regulations for health and safety

Disinfection and decontamination:

  • Exterior casing and mechanical surfaces must be wiped with a clean cloth, dampened with a disinfectant
  • Soft plastic parts and rubber surfaces can be cleaned by gently wiping a clean cloth, dampened with a disinfectant. Discoloration can occur if alcohol is used
  • The front lens of eyepieces and objectives are sensitive to chemicals. We recommend not to use aggressive disinfectants but to use lens paper or a soft fibre-free tissue, damped in cleaning solution. Cotton swabs may also be used. We recommend you use personal eyepieces without eyeshades in order to minimize risk
  • Never immerse or dip the eyepiece or objective into a disinfectant liquid! This will damage the component
  • Never use abrasive compounds or cleaners that may damage and scratch optical coatings
  • Properly clean and disinfect all possible contaminated surfaces of the device or contaminated accessories before storing for future use. Disinfection procedures must be effective and appropriate
  • Leave the disinfectant on the surface for the required exposure time, as specified by the manufacturer. If the disinfectant evaporates before the full exposure time, reapply disinfectant on the surface
  • For disinfection against bacteria, use a 70% aqueous solution of isopropanol (isopropyl alcohol) and apply for at least 30 seconds. Against viruses, we recommend to refer to specific alcohol or non-alcohol based disinfection products for laboratories.

Before returning a device for repair or maintenance through a Euromex dealer, an RMA (return authorization form) together with a decontamination statement must be filled in! This document – available from Euromex for any reseller­must be shipped together with the device at all times.

Reference documents:

World Health Organisation:
https://www.who.int/ihr/publications/biosafety-video-series/en/

US Centre for Disease Control and prevention
https://www.cdc.gov/infectioncontrol/guidelines/disinfection/index.html

Handle with care

  • This product is a high quality optical instrument. Delicate handling is required.
  • Avoid subjecting it to sudden shocks and impacts.
  • Impacts, even small ones, can affect the precision of the instrument.

Dirt on the lenses

  • Dirt on or inside the optical components, such as eyepieces, lenses, etc., affects the image quality of your system negatively
  • Always try to prevent your device from getting dirty by using the dust cover, prevent leaving fingerprints on the lenses and clean the outer surface of the lens regularly
  • Cleaning optical components is a delicate matter. Please, read the cleaning instructions further on in this manual

Environment, storage and use

  • This product is a precision instrument and it should be used in a proper environment for optimal use
  • Install your product indoors on a stable, vibration free and level surface in order to prevent this instrument to fall thereby harming the operator
  • Do not place the product in direct sunlight
  • The ambient temperature should be between 5 to +40°C and humidity should be within 80% and 50%
  • Although the system is anti-mold treated, installing this product in a hot, humid location may still result in the formation of mold or condensation on lenses, impairing performance or causing malfunctions
  • Never turn the right and left focus knobs in opposite directions at the same time or turn the coarse focus knob past its farthest point as this will damage this product
  • Never use undue force when turning the knobs
  • Make sure that the device can dissipate its heat (fire hazard)
  • Keep the device away from walls and obstructions for at least approximately 15 cm
  • Never turn the device on when the dust cover is in place or when items are placed on the device
  • Keep flammable fluids, fabric, etc. well out of the way.

Disconnect power
Always disconnect your device from power before doing any maintenance, cleaning, assembling or replacing LEDs to prevent electric shocks

Prevent contact with water and other fluids
Never allow water or other fluids to come in contact with your device, this can cause short circuiting your device, causing malfunction and damage to your system

Moving and assembling

  • This device is a relatively heavy system, consider this when moving and installing the system
  • Always lift the device by holding the main body and base of the device
  • Never lift or move the device by its focusing knobs, stage or head
  • When needed, move the device with two persons instead of one

Introduction

This digital MacroZoom (MZ.4600) is equipped with a 0.7 to Sx zoom objective enables direct inspection of objects on external HD screen (not supplied). The mouse-driven built-in software controls the camera parameters and enables measurements on screen, capturing and saving .jpg or .bmp format pictures and .mp4 format video on a USB memory stick. The MZ.4600 has a built-in High Definition 1080p 2MP camera which can deliver up to 60 images per seconds and needs to be connected to an external stand-alone HD screen

Device parts

  • A. Device head
  • B. Light intensity controlCamera interface
  • C. Magnification wheel
  • D. Camera interface
  • E. Fixing screw
  • F. Focus knob
  • G. Ring light
  • H. Head holder
  • I. Safety ring
  • J. Pillar
  • K. Base

Set up

Camera installation instructions

  1. Please use the power adapter to power up the camera.
  2. Connect the mouse.
  3. Connect the camera and monitor with HDMI cable.
  4. Optionally, connect a USB storage device.

Menu interface
Move cursor to the upper left corner to open the interface

Control
See image 4.1

Measurement
See image 4.2.

Control interface

Language mode
Click the upper left corner of the menu to select the language mode

Lock menu
Click the lock icon in the upper right corner of the menu to switch the menu display status

  • Always show menu when “blocked”
  • When “Open”. move the mouse to the upper left area menu display, move out of the upper left area menu to hide

Exposure

Exposure : Auto \ Manual

  • When “AE” (Automatic exposure) is selected, you can drag the “Bright” progress bar to adjust the brightness
  • When “ME” (Manual exposure) is selected, you can adjust the “Gain”, and the “Exposure Time” progress bar to adjust the shutter.

Default: Automate exposure

White balance
White balance: Auto \ Manual

  • AWB : automatic white balance can be achieved under different color temperatures
  • MWB : You can drag the “Red” “Green” “Blue” progress bars to adjust the color value

Function

Function : Contrast\Sharp\Saturation\Zoom

  • Contrast : 0-100 value adjustable, the default value is 50
  • Sharp : 0-15 value adjustable, the default value is 4
  • Saturation : 0-254 value adjustable, the default value is 128
  • Zoom : 1.0-6.0 value adjustable, the default value is 1.0

Flip/Mirror

  • Flip : the vertical direction of the video on the screen is the opposite of the actual
  • Mirror : the horizontal direction of the video on the screen is the opposite of the actual

WDR

WDR : In very strong contrast, click on the WDR to see the brighter and darker areas of the object.
Note: The frame rate of the image will drop to 30fps after WDR is checked.

Gamma

Gamma : 0-3 value adjustable, the default value is 1.

Anti-screen flicker
When checked, anti-screen flicker effect is achieved

Black and white mode
Checked for black and white mode, default is color mode

Crosshair tool

  1. Click Crosshairs tool – + -, select “cross line”, display crosshairs to set the number of horizontal and vertical lines. After the setting is complete, select “Display” to display the set cross hairs in the image display area, and select “Delete” to not display crosshairs
    Display crosshairs:
    Hold the left button to drag the crosshairs
    Note : Do not press and hold at the intersection of the horizontal and vertical lines Double-click a single crosshair to set its color and position, center and delete.

  2. Click Crosshairs tool – + -, select “Cross Mark”, image area displays cross tick marks

  3. Click Crosshairs tool – + -, select “Hide”, all cross lines or cross tick marks will be hidden in the image area

  4. Click on the Crosshairs color tool –   -, Pull down to set the cross hairs color. After the color is set, draw the crosshairs again to take effect, the color of the crosshairs drawn before does not change

Photos

Photo operation
First confirm whether the USB drive is inserted successfully.

Prefix
When the “Naming” is “Auto”, the prefix of the file name can be added, and the file is named and saved with “prefix+ serial number”

Photo format
Click on the photo format drop-down to select the photo format. There are two formats to choose from: .jpg/.bmp

Photo naming rules

  • Select “Auto” to name the photo according to the time
  • Select “Manual” to enter a name to save

Recording

  • Click on “record” – -, the interface prompts “Begin recording”. Click “OK” to confirm starting recording.
  • During recording, the icon in the lower right corner of the screen flashes – -.
  • Click on “Record” icon again, the interface prompts “Recording stopped”. Click “OK” to confirm stopping recording.

Remark : The recorded video is named “video+ serial number”, and is automatically saved in the USB drive in the .mp4 format. The maximum length of a single recording is approx. 2 hours, the maximum size is approx. 4 GB. If it exceeds 2 hours, it will automatically stop recording.

Freeze
Click “Freeze” – -, The current image will be frozen, and the image window remains static, which makes it easy to observe the measured object; After freezing, the icon becomes – -.Click this icon to restore real-time display

Save graphics

When “Yes” is checked, the upper measurement line is saved in the picture, while “No” is not saved

Version number
At the bottom of the menu, you can view the current software version number

Detailed measurement interface
Click the measurement tab to carry out the measurement operation. In case you want to display the menu, after the measurement operation is completed; right- click in the image area and move the mouse to the menu area to display the menu

Assist tool

Color setting
Click “color setting” – -, to pop-up color setting interface.

Edge detection
Click “Edge Detection”  When selected, the icon turns blue. When measuring a picture, it will automatically find the edge.

Measurement tool

Custom template
After drawing the artwork for your template (primitives) in the image area, click “New” folder, and the window “Whether to convert a primitive to a template” pops up. Click “OK” to create a new template

Measurement operation

Calibration

  1. Click on the calibration tool drop down:
    “Line Calibration”, “H Calibrate” or “Circle Calibrate” can be chosen

  2. Drag the marking line to align with the engraved line of the scale, enter name and length, select the unit and complete the calibration.
    Delete calibration: Click the drop-down calibration list, select the calibration group to be deleted and click the “delete” icon to delete this group of calibrations:

Measuring
The measurement tool includes a variety of stitch measurements. Depending on the specific application, you can first select the appropriate calibration and unit

  • Pull down the calibration list and select the calibration.
  • Then select the appropriate tool for measurement; when measuring, you only need to click the anchor point of the measurement. After you click and release the mouse, the measurement data is displayed in the measurement data list area.

After the measurement is completed, you can export the data in the measurement data list.

  • Click “Export Data” and the data will automatically be saved in the .csv file in the USB drive. The user can input the file name
  • Delete measurement data: In the measurement data list, select the data you want to delete, right-click, you will be prompted to delete a group of data, or delete all data, and select according to your needs

Select measurement data
Left-click the data in the measurement data list to select it. The color of the selected graphic in the image will be highlighted

Selected graph
Double-click the data in the measurement data list and a dialog box will pop up. You can modify the line color and line width and lock the selected graph. The locked graph can no longer be operated

Detailed data
Double-click on “List Show” – List Show – to pop up the detailed data dialog box to view all the current detailed measurement data

Mark tool
Click “Text” – T -. Draw the position to be marked in the image area, enter the comment content in the pop-up window, and click “OK” to complete the marking

Note : some instructions are slightly different, please focus on the actual menu and operation.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals