Vacmaster VJH1211PF 0201 Wet or Dry Vacuum Cleaner with Detachable Blower Owner’s Manual
- June 9, 2024
- Vacmaster
Table of Contents
- VJH1211PF 0201 Wet or Dry Vacuum Cleaner with Detachable Blower
- WARRANTY
- SAFETY INSTRUCTIONS & WARNINGS
- DOUBLE INSULATION INSTRUCTIONS
- EXTENSION CORDS
- UNPACKING & CHECKING CARTON CONTENTS.
- GENERAL ASSEMBLY INSTRUCTIONS
- DRY VACUUM OPERATION
- LIQUID VACUUM OPERATION
- BLOWER OPERATION
- MAINTENANCE
- INSTALLING & CLEANING CARTRIDGE FILTER
- TROUBLESHOOTING
- EXPLODED VIEW
- PARTS LIST
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Wet/Dry Vacuum
Wet/Dry Vacuum with Detachable Blower
12 Gallon
Model No.
VJH1211PF 0201
FOR YOUR SAFETY
Read and understand this manual before use.
Keep this manual for future reference.
Owner’s Manual
VJH1211PF 0201 Wet or Dry Vacuum Cleaner with Detachable Blower
Thank you for purchasing this Vacmaster® wet/dry vacuum cleaner. Feel
confident that with Vacmaster® you are obtaining a high quality product
engineered for optimal performance.
This vacuum is capable of picking up liquids and dry materials.
FOR YOUR SAFETY: CAREFULLY READ AND UNDERSTAND ALL INSTRUCTIONS.
WARRANTY
We take pride in producing a high quality, durable product. This Vacmaster® product carries a limited two (2) year warranty against defects in workmanship and materials from date of purchase under normal household use. If product is to be used for commercial, industrial, or rental use, a 90 day limited warranty will apply. Please keep your receipt as proof of purchase. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state. For product service call Customer Service at 1-866-384-8432.
Not Covered by Warranty:
- Any part that has become inoperative due to misuse, negligence, direct/indirect abuse, accidents, improper maintenance, repairs, or alterations;
- Consumables such as filters and accessories;
- Normal wear and tear of parts and attachments, such as hose, nozzles, or casters;
- Normal deterioration of the exterior finish due to use or exposure;
- Any product where serial number/data label is tampered with or removed;
- Any product purchased from an unauthorized retailer.
SAFETY INSTRUCTIONS & WARNINGS
IMPORTANT SAFETY INSTRUCTIONS
Read and understand all instructions before using this vacuum.
Read and understand this owner’s manual and all labels on the Wet/Dry Vacuum
cleaner before operating. Safety is a combination of common sense, staying
alert, and knowing how your vacuum works. Use this Wet/Dry Vac only as
described in this manual. To reduce the risk of personal injury or damage to
your Wet/Dry Vac, use only Vacmaster® recommended accessories.
For Household Use Only.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:
- Do not run vac unattended.
- Do not vacuum, or use this Wet/Dry Vac near flammable liquids, gases, or explosive vapors like gasoline or other fuels, lighter fluids, cleaners, oil-based paints, natural gas, hydrogen, or explosive dusts like coal dust, magnesium dust, grain dust, or gun powder. Sparks inside the motor can ignite flammable vapors or dust.
- Do not vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
- Keep cord away from heated surfaces.
- Do not expose to rain. Store indoors.
- Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
- Do not use with damaged cord, plug or other parts.
- If your Wet/Dry Vac is not working as it should, has missing parts, has been dropped or damaged, left outdoors, or dropped into water, return it to an independent service center.
- Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp edges or corners.
- Do not run Wet/Dry Vac over cord.
- Do not handle plug or the Wet/Dry Vac with wet hands.
- To reduce the risk of health hazards from vapors or dusts, do not vacuum toxic materials.
- Do not use or store near hazardous materials.
- Do not use this Wet/Dry Vac with a torn filter or without the filter installed except when vacuuming liquids as described in the operation section of this manual.
- Do not allow to be used as a toy. Close attention is necessary when used by or near children.
- To reduce the risk of injury from accidental starting, unplug power cord before changing or cleaning filter.
- Do not leave Wet/Dry Vac unattended when plugged in. Unplug from outlet when not in use and before servicing.
- Turn off Wet/Dry Vac before unplugging.
- Do not put any object into ventilation openings. Do not vacuum with any ventilation openings blocked; keep free of dust, lint, hair or anything that may reduce air flow.
- Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
- To reduce the risk of falls, use extra care when cleaning on stairs.
When using as blower:
- Direct air discharge only at work area.
- Do not use Wet/Dry Vac as a sprayer.
- Do not direct air at bystanders.
- Keep children away when blowing.
- Wear safety goggles.
DOUBLE INSULATION INSTRUCTIONS
This Wet/Dry Vac is double-insulated, eliminating the need for a separate grounding system. Use only identical replacements parts. Read the instructions for Servicing Double-Insulated Wet/Dry Vacs before servicing. Use this Wet/Dry Vac as described in this manual. Observe the following warnings that appear on the motor housing of your Wet/Dry Vac.
DOUBLE INSULATED – GROUNDING NOT REQUIRED – WHEN SERVICING USE ONLY IDENTICAL
REPLACEMENT PARTS.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN.
STORE INDOORS.
WARNING: FOR YOUR OWN SAFETY, READ AND UNDERSTAND OPERATOR’S MANUAL. DO
NOT RUN UNATTENDED. DO NOT PICK UP HOT ASHES, COALS, TOXIC, FLAMMABLE, OR
OTHER HAZARDOUS MATERIALS. DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS.
CAUTION:
-
Do not vacuum drywall dust or fireplace soot or ash with standard Wet/Dry filter. This is a very fine dust which will not be captured by the filter and may cause damage to motor. When vacuuming fine dust use a fine dust filter (sold separately).
WARNING: SERVICING OF DOUBLE-INSULATED WET/DRY VACUUM
WITH A DOUBLE-INSULATED WET/DRY VACUUM, TWO SYSTEMS OF INSULATION ARE PROVIDED INSTEAD OF GROUNDING. NO GROUNDING MEANS IS PROVIDED ON A DOUBLE-INSULATED APPLIANCE, NOR SHOULD A MEANS FOR GROUNDING BE ADDED. SERVICING A DOUBLE INSULATED WET/DRY VACUUM REQUIRES EXTREME CARE AND KNOWLEDGE OF THE SYSTEM, AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL. REPLACEMENT PARTS FOR A DOUBLE-INSULATED WET/DRY VACUUM MUST BE IDENTICAL TO THE PARTS THEY REPLACE. YOUR DOUBLE-INSULATED WET/ DRY VAC IS MARKED WITH THE WORDS ‘DOUBLE INSULATED’ AND THE SYMBOL . (SQUARE WITHIN A SQUARE) MAY ALSO BE MARKED ON THE APPLIANCE. -
To reduce the risk of electric shock, unplug before cleaning or servicing.
-
DO NOT use without filters in place.
CAUTION: TO REDUCE THE RISK OF INJURY FROM MOVING PARTS, UNPLUG BEFORE SERVICING.
EXTENSION CORDS
When using an extension cord with your Wet/Dry Vac refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the vacuum cleaner. Only use extension cords that are rated for outdoor use.
| Length of Extension Cord
---|---
110V-120V| 25 Feet
7.5 Meters| 50 Feet
15.25 Meters| 100 Feet
30.5 Meters| 150 Feet
45.7 Meters
Amps| A.W.G. Wire Size
0-6| 18| 16| 16| 14
7-10| 18| 16| 14| 12
11-12| 16| 16| 14| 12
13-16| 14| 12| Not recommended
UNPACKING & CHECKING CARTON CONTENTS.
Remove all contents from the box. Remove the power head and take out any contents inside the collection tank. Check each item against the carton contents list.
Carton Contents List:
Key Description …………………………………. Qty.
A Vac Assembly…………………….…..1
B Hose…………………….……………..1
C Utility Nozzle……….………………….1
D Caster Foot w/Accessory Storage…..2
E Caster………………………………….4
F 4 Screws (Bag)………………………..4
G Foam Wet Filter……..…………………..1
H Extension Wand………………………1
I Car Claw………….……………………2
J Concentrator Nozzle…………………..1
K Crevice Tool……….…………………..1
L Cartridge Filter…………………….….1
M Filter Retainer………………………….1
N Adapter………………………………..1
O Diffuser…………………………………1
P Operator’s Manual…..……………….. 1
NOTE: The hose and accessories for this vacuum are 2-1/2” diameter.
GENERAL ASSEMBLY INSTRUCTIONS
A Philips head screw driver is required.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN. MAKE SURE PLUG IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VAC.
UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY
-
Verify that the power cord is disconnected from the outlet. (fig. 1)
-
Undo the latches. (fig. 2)
-
Lift the power head off the collection tank. (fig. 3)
-
Remove the contents from inside the collection tank; make sure you have all contents as listed on page 5. (fig. 4)
-
Turn the collection tank upside down and insert the four caster feet into the slots on the collection tank and tighten with supplied screws. Verify that the casters are mounted correctly.
Do not over-tighten screws. (fig. 5) -
Your vacuum comes ready for dry vacuum cleaning. For filter installation instructions, see page 10. (fig. 6 & 7)
-
For wet vacuum cleaning, install the supplied foam filter. (fig. 8) For installation instructions, see page 11.
-
Place the power head back on the collection tank, aligning the top section with the latches, and snap into place. Keep in mind to position the power head so that the blower port is towards the rear. (fig. 9)
-
Insert the locking end of the hose into the port of the collection tank and lock into place. (fig. 10)
-
Choose the desired wands or accessories and push onto the hose. (fig. 11)
NOISE DIFFUSER
For quiet operation during vacuuming, install the noise diffuser into the
blower port by inserting the locking end of the diffuser into the blower port
and turning clockwise to
lock into place.
POLARIZED PLUG
To reduce the risk of electrical shock, this appliance has a polarized plug
(one blade wider than the, other). This plug will fit in a polarized outlet
only one way. If the plug does not fit fully in the outlet, reverse the plug.
If it still does not fit, contact a qualified electrician to install the
proper outlet.
Do not change the plug in any way. Double insulation eliminates the need for
the three wire grounded power cord and grounded power supply system.
DRY VACUUM OPERATION
DRY VACUUMING
WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY, INFORMATION, ENTITLED
‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES,
VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT
ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASED PAINTS,
GASOLINE, ALCOHOL, OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT
LIMITED TO: COAL, MAGNESIUM, GRAIN, OR GUN POWDER. TO REDUCE THE RISK OF
HEALTH HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.
-
Verify that the power cord is disconnected from the outlet. (fig.1)
-
In order to prepare your vacuum for dry vacuuming, verify that the cartridge filter is securely、 mounted. Make sure the filter is pushed in until it stops against the power head. (fig. 2) Your
Wet/Dry Vac comes with the cartridge filter pre-installed. For insta lation instructions, see page 10. -
Place filter retainer on top of cartridge filter and tighten down by turning the retainer handle clockwise. (fig. 3)
-
Place the power head back on the collection tank, aligning the top section with the latches, and snap into place. (fig. 4)
OPERATING INSTRUCTIONS: DRY VACUUMING -
Insert the locking end of the hose into the vacuum port on the front of the tank and lock into place. Push the required attachment onto the free end of the hose or extension. (fig. 5)
-
Plug in the power cord into the outlet. (fig. 6)
-
Turn the motor on by flipping the switch to the ‘I’ ON position. (fig. 7)
-
Once you have completed vacuuming, flip the switch to the ‘O’ OFF position and unplug the power cord from the outlet.
O = OFF I = ON
DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING.
DO NOT USE DUST BAG FOR LIQUID VACUUMING.
LIQUID VACUUM OPERATION
LIQUID VACUUMING
WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY, INFORMATION, ENTITLED
‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES,
VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT
ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASED PAINTS,
GASOLINE, ALCOHOL, OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT
LIMITED TO: COAL, MAGNESIUM, GRAIN, OR GUN POWDER. TO REDUCE THE RISK OF
HEALTH HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.
WARNING: DO NOT PLUG POWER CORD INTO POWER OUTLET, MAKE SURE PLUG IS
DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VAC
-
Verify that the power cord is disconnected from the outlet. (fig. 1) Verify that the collection tank is clean and free of dust and dirt.
-
Remove cartridge filter, then carefully install the foam wet filter over the filter cage and place the power head back on the collection tank. (fig. 2) For filter installation instructions, see page 11.
DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING.
OPERATING INSTRUCTIONS: WET VACUUMING -
Fit the desired nozzle to the vacuum hose. (fig. 3)
-
Verify that the switch is in the ‘O’ OFF position before plugging the power cord into the outlet. (fig. 4)
-
Turn the motor on by flipping the switch to the ‘I’ ON position. (fig. 5)
-
After use, empty the collection tank by unscrewing the drain cap. Drain liquids into a suitable receptacle or drain. Remember to refit the drain cap to the collection tank. (fig. 6)
IMPORTANT! When vacuuming large quantities of liquids, do not immerse the nozzle completely in the liquid; leave a gap at the tip of the nozzle opening to allow air inflow. The machine is fitted with a float valve that stops the suction action when the collection tank reaches its maximum capacity. You will notice an increase in motor speed. When this happens, turn off the machine, disconnect from power supply, and drain the liquid into a suitable receptacle or drain. To continue vacuuming, refit the collection tank with the drain cap. After wet vacuuming, turn the machine off and remove plug from power supply. Empty the collection tank, clean, and dry the inside and outside before storage. REMEMBER! The foam filter must be removed after wet vacuuming, and a cartridge filter must be installed before dry vacuuming again.
BLOWER OPERATION
This Wet/Dry Vac converts to a detachable blower that can be used for leaf
blowing in yards, decks and patios. To use the detachable blower feature
follow the instructions listed.
WARNING: ALWAYS WEAR SAFETY GOGGLES COMPLYING WITH ANSI Z87.1 (OR IN CANADA,
CSAZ94.3) BEFORE USING BLOWER.
CAUTION: TO REDUCE THE RISK OF HEARING DAMAGE, WEAR EAR PROTECTION WHEN USING
THE VAC/BLOWER FOR EXTENDED HOURS OR WHEN USING IT IN NOISY AREAS.
WARNING: KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS.
WARNING: WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED.
- Verify that the power cord is disconnected from the outlet. (fig. 1)
- Remove noise diffuser from the blower port. (fig. 2)
- While squeezing the locking lever, lift the detachable blower from the vacuum lid. (fig. 3 & 4)
- Insert the adaptor into the blower port and fit it the desired extension wands and or nozzles. (fig. 5 & 6)
- Ensure the power switch is turned off and plug into the power supply. (fig. 7)
- Firmly hold the blower before turning it on. Turn the motor on by flipping the switch to the ‘I’ ON position. (fig. 8)
MAINTENANCE
WARNING! ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE REMOVING THE POWER HEAD FROM THE COLLECTION TANK.
- Verify that the power cord is disconnected from the outlet. (fig.1)
- Disconnect the hose from the unit. (fig. 2)
- Undo the latches and remove the power head from the collection tank. (fig. 3)
- Clear all dirt or debris from the collection tank and hose. (fig. 4)
- Clean the foam filter by washing it with water and mild soap. (fig. 5)
- Check the hose, attachments, and power cord to verify that they have not been damaged.
BLOWER INTAKE
After using the blower, examine the bottom of the blower for debris and blockages and remove if found. To clean the foam pad of the intake:
WARNING! ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE REMOVING
THE POWER HEAD FROM THE COLLECTION TANK.
- Verify that the power cord is disconnected from the outlet. (fig.1)
- Remove the four screws holding the intake shield and lift off the shield. (fig.2)
- Remove the foam padVacmaster VJH1211PF 0201 Wet or Dry Vacuum Cleaner with Detachable Blower – fig 01 from the blower and clean the foam pad with soapy water and allow to dry. (fig. 3)
- Check the foam pad for reuse. If you need to replace the foam pad consult the parts list of the manual.
- Replace the foam pad on to the blower aligning the wholes to the screw tabs. (fig. 4)
- Reinstall the intake shield and the four screws. (fig. 5)
INSTALLING & CLEANING CARTRIDGE FILTER
Installing Cartridge Filter
-
Remove lid and power head and place in upside down position.
-
Install the cartridge filter over the filter cage with the flat end of the filter towards the vacuum lid.
Carefully push filter in until it stops against the lid. (fig. 2 & 3) -
Place filter retainer on top of cartridge filter over the raised lip and tighten down by turning
Wet-dry-vac.com allows you to learn about how to purchase a wet/dry vac, compare and review detailed specifications on hundreds of models, and find compatible filters.\
TROUBLESHOOTING
WARNINTROUBLESHOOTING
WARNING! TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.G! TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.
Symptom | Possible Causes | Corrective Action |
---|---|---|
Vacuum will not operate | 1) No power supply. | 3) Empty c1) Check power supply |
– cord,
breakers, fuses.ollection tank.
| 3) Collection tank full.| missing
- Attach or replace cartridge
filter.2) Unplug and check the power
cord. If damaged, have it
repaired by a professional.
| 1) The cartridge filter is missing or damaged.| 1) Attach or replace cartridge
filter.
| 1) There is a blockage in the nozzle, hose, or the collection tank inlet. The cartridge ilter is
clogged by fine dust.| 1) Check nozzle, hose and
collection tank inlets for
blockage. Take off the filter and
clean it or install a new cartridge
filter.
EXPLODED VIEW
Part | Drawing Number | Description | Quantity |
---|---|---|---|
1 | Power head assembly | 1 | |
2 | 551002106 | Container lid assembly | 1 |
3 | 551008115 | Float | 1 |
4 | 551019117 | Filter cage | 1 |
5 | Collection tank | 1 | |
6 | 551002112 | Vacuum port assembly | 1 |
7 | 551323103 | Drain cap with gasket | 1 |
8 | 551006109 | Caster foot assembly | 4 |
9 | 551002121 | Blower adapter | 1 |
10 | 551006113 | 2-1/2″ Crevice tool | 1 |
11 | 551002115 | Blower concentrator nozzle | 1 |
12 | 551002119 | Car nozzle | 1 |
13 | 551006111 | 2-1/2″ Utility nozzle | 1 |
14 | 551002113 | 2-1/2″ x 7′ Hose | 1 |
15 | 551002116 | 2-1/2″ Extension wand | 2 |
16 | 551002118 | Foam wet filter | 1 |
17 | 551030114 | Cartridge filter | 1 |
18 | 551004104 | Retainer for washable filter | 1 |
19 | Operator’s manual | 1 | |
20 | 551002117 | Noise diffuser | 1 |
PARTS LIST
You can also view manuals,
parts lists and brochures for hundreds of models. Plus, you can find the best
prices for vacuums and filters, and purchase online right from the site.
Wet-Dry-Vac.com Site Copyright ©2023 Christopher Komuves
Wet/Dry Vacuumwi Detachable Blower 12 Gallon
odel No.
VJH1211PF 0201
FOR YOUR SAFETY
Read and understand this manual before use. Keep this manual for future
reference.
Wet/Dry Vacuum with Detachable Blower
12 Gallon
Model No.
VJH1211PF 0201
FOR YOUR SAFETY
Read and understand this manual before use.
Keep this manual for future reference.
Model No.
VJH1211PF 0201
FOR YOUR SAFETY
Read and understand this manual before use.
Keep this manual for future reference.
References
- Vacmaster
- Wet/Dry Shop Vacuum Comprehensive Search, Reviews & Buying Guide
- Wet/Dry Shop Vacuum Comprehensive Search, Reviews & Buying Guide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>