Software
INTRODUCTION
The VIS-MINI-CNTRL is a mini single door control panel, can work with any entry device Wiegand 26~37 bits output reader. Card type depends on the reader, example: EM, HID, and MFR card types. It uses Atmel microcontroller to assure stable performance and equips with an infrared remote control for easy operation. The VIS-MINI-CNTRL supports 1,000 users; all user data can be transferred.
- If the VIS-MINI-CNTRL is connected to a keypad/reader you must first set the keypad into Wiegand mode for it to communicate correctly with the VIS-MINI-CNTRL (Refer to page No. 8).
- All programming will be done in the VIS-MINI-CNTRL but not on the keypad/reader. Is also highly suggested to change the master code in the VIS-MINI-CNTRL (Refer to page No. 7 and page No. 8 ).
Features
- 1,000 users’ user data can be transferred
- Multi access modes: Card, Card or PIN, Card with PIN and multi-Cards/PINs
- Can connect with any reader with Wiegand 26~37 bits output
- Can connect with any keypad reader with 4bits, 8bits (ASCII), or 10bits
- Virtual number output
- Support Master Card function
- Low temperature resistance (-40°C)
Specifications
User Capacity | 1,000 |
---|---|
Operating Voltage Idle Current | 9~24V DC |
<20mA
Relay
Adjustable Relay Output Time Lock Output Load
| One (NO, NC, Common)
1~99 Seconds (5 seconds default) 2 Amp Maximum
Wiegand Interface Input
Output
|
Wiegand 26~37 bits
Wiegand 26~37 bits (for user transfer)
Environment
Operating Temperature Operating Humidity
| Indoor. Meets IP66
-40°C~60°C (-40°F~140°F) 0~90%RH
Physical Dimensions
Unit Weight Shipping Weight
| ABS Shell
L65 x W54 x H19 (mm) L2.56 x W2.13 x H0.75 (in.)
40g 100g
Carton Inventory
VIS-MINI-CNTRL Mini Controller: Infrared Remote Control
INSTALLATION
Wiring
Name | Notes |
---|
The Left Side
LED| Green LED Light Control
D1| Wiegand Input Data 1
D0| Wiegand Input Data 0
GND| Negative Pole of DC (9~24V) Power Input
+DC| Positive Pole of DC (9~24V) Power Input
The Right Side
OPEN| Connect to One Wire of Exit Button
NO| Normally Open Relay Output (install diode provided)
GND (COM)| Negative Pole of Lock
(Common Connection for Relay Output)
NC| Normally Closed Relay Output (Install diode provided)
Sound and Light Indication
Operation Status | LED | Buzzer |
---|---|---|
Stand by | Red light bright | |
Enter programming mode | Red light shines | One beep |
In the programming mode | Orange light bright | One beep |
Operation error | – | Three beeps |
Exit from the programming mode | Red light bright | One beep |
Open lock | Green light bright | One beep |
Connection Diagram
Fail-Safe Lock (Magnetic Lock, Electric Strike, Drop Bolt)
This connection works for all the VIS-3000 Series keypads
Fail-Secure Lock (Electric Strike or Drop Bolt) or Door/Gate Operator
This connection works for all the VIS-3000 Series keypads
Remark:
The power supply’s voltage must be the same with lock’s supply voltage, or
else, the lock will not work properly or be damaged.
- The Master Cards are not included in the standard packing. The type of the Master Cards is according to the external reader. For example: the external reader is 125KHz
- HID Reader, then the Master Cards must be 125KHz HID cards.
- If no Master Cards added, must press the Exit Button for at least 10 seconds before release.
- Reset to factory default, the user’s information is still retained.
PROGRAMMING
Programming will vary depending on access configuration. Follow the
instructions according to your access configuration.
Notes:
- Remote Control: Please use the Infrared Remote Control to program the VIS-MINI-CNTRL. The “IR” on the VIS-MINI-CNTRL is the infrared receiving window, please direct the Remote Control to it.
- User ID number: Assign a user ID to the access card in order to track it. The common user ID number can be any number from 0~999. IMPORTANT: User IDs do not have to have proceeded with any leading zeros. Recording of the User ID is critical. Modifications to the user require the User ID be available.
- PIN: Can be any 4~6 digits except 8888 which is reserved.
Enter and Exit Program mode
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
(Factory default is 123456)
2. Exit Program Mode|
Set Master Code
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Update Master Code
| 0 (New Master Code) # (Repeat New Master Code) # (code: 6 digits)
3. Exit Program Mode|
Add Users with Remote Control
VIS-MINI-CNTRL Connected with Card Reader:
For the readers develop together with VIS-MINI-CNTRL, such as 3000 Series
readers, skip the below step 1; For other card readers, set the VIS-MINI-
CNTRL’s Wiegand input as below step 1 according to the Wiegand output of the
readers.
VIS-MINI-CNTRL Connected with Keypad Reader:
Can be any Keypad Reader with 4Bits, 8Bits (ASCII), 10Bits output format
Set the VIS-MINI-CNTRL as below step 1 according to the Wiegand output and PIN
output format of the Keypad Reader.
The 3000 series keypad must be set to Wiegand mode by entering the following
sequence (in the keypad itself):
Press: *, master code (Default is 999999), #, 310, #,
PIN(s) can be input/added on either the remote control or the external Keypad
Reader, except when the Keypad Reader is 10 digits virtual card number output,
the PIN(s) can only be input/added through the Keypad Reader.
Step 1**
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Wiegand Input bits PIN Input bits | **8 (26~37) # (Factory default is |
26bits)**
8 (4 or 8 or 10) # (Factory default is 4bits)
3. Exit Program Mode|
Remarks: 4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual number.
Step 2
Programming Step | Keystroke Combination |
---|
Add Card User
1. Enter Program Mode| (Master Code) #
2. Add Card: Using Auto ID (Allows VIS-MINI-CNTRL to assign Card to next
available User ID number)
OR
2. Add Card: Select Specific ID (Allows Master to define a specific User ID to associate the card to) OR
2. Add Card: by Card Number OR
2. Add Card: Block Learn (Allows Master to add up to 1000
cards to the Reader in a single step.) Takes 2 minutes to program
| 1 (Read Card on External Reader) #
Repeat Step 2 for additional user cards
1 (User ID) # (Read Card on External Reader) #
The user ID is any number from 0-999
1 (Input 8/10 digits Card number) #
1 ( User ID number) # (Card quantity) # (The first card number) #
Cards’ number must be consecutive.
Card quantity = number of cards to be enrolled
3. Exit Program Mode|
Add PIN User
1. Enter Program Mode| (Master Code) #
2. Add PIN: Using Auto ID
(Allows VIS-MINI-CNTRL to assign PIN to next available User ID number)
| 1 (Input PIN) #
Repeat Step 2 for additional user cards (PIN: 4~6 digits)
2. Add PIN: Select Specific ID (Allows Master to define a specific User ID to associate the card to)| 1 (User ID) # (Input PIN) #
The user ID is any number from 0-999 (PIN: 4~6 digits)
3. Exit Program Mode|
VIS-MINI-CNTRL Connected with Fingerprint Reader:
For example: Connect the fingerprint reader to VIS-MINI-CNTRL, two steps to
enroll the valid fingerprint.
- Add the Fingerprint (A) on the reader
- Add the same Fingerprint (A) on VIS-MINI-CNTRL as below:
| Enter Program Mode: (Master Code) #
---|---
2
OR
2
| 1 (Press Fingerprint A on the reader) (Repeat Fingerprint A on the reader) # (ID auto allocated)
1 (User ID) # (Press Fingerprint A on the reader) (Repeat Fingerprint A on the reader) # (Select specific ID)
3| Exit:
Add Users by Master Add Card
- Add card users
- Master Add Card – Read User Card – Master Add Card
- (Cards can be added continuously)
- Add PIN users
- Master Add Card – Input PIN – Master Add Card
- (PINs can be added continuously)
Change PIN
Programming Step | Keystroke Combination |
---|
Note: Below is done outside programming mode, users can undertake this
themselves
1. Enter Program Mode| (Master Code) #
1. Change the card associated PIN (There will auto associate PIN (8888) to
cards when adding card users)| (Read Card) (Old PIN) # (New PIN) # (Repeat
New PIN) #
(PIN: 4~6 digits)
1. Change the users’ PIN
| (ID Number) # (Old PIN) # (New PIN) # (Repeat New PIN) #
(PIN: 4~6 digits)
2. Exit Program Mode|
Delete User Card(s) or PIN(s) by Remote Control
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Delete User By User ID
OR
2. Delete User – By Card
OR
2. Delete User – By Card number
OR
2. Delete User – By PIN
OR
2. Delete All User
| 2 (User ID ) #
2 (Read Card on External Reader) # 2 (Input 8/10 digits Card number) # 2 (Input PIN) #
2 (Master Code) #
---|---
3. Exit Program Mode|
Delete Users by Master Delete Card
- Delete card users
- Master Delete Card – Read Card – Master Delete Card
- (Cards can be deleted continuously)
- Delete PIN users
- Master Delete Card – Input PIN – Master Delete Card
- (PINs can be deleted continuously)
Set Relay Configuration
The relay configuration sets the behavior of the output relay on activation.
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Pulse Mode | 3 (1~99) # |
The relay time is 1~99 seconds. (1 is 50mS) | |
OR | (Factory default is 5 seconds) |
2. Toggle Mode | 3 0 # |
Sets the relay to ON/OFF Toggle mode | |
3. Exit Program Mode |
Set Access Mode
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Card access | 4 0 # |
OR | |
2. Card + PIN access | 4 1 # |
OR | |
2. Card or PIN access | 4 3 (Factory default) |
OR | |
2. Multi cards/PINs access | 4 3 (2~9) # |
3. Exit Program Mode |
Set Audible and Visual Response
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Control Sounds | OFF = 7 0 # |
OR | |
2. Control LED | OFF = 7 4 # |
(Factory defaults are ON) | |
3. Exit Program Mode |
User Information Transfer
The VIS-MINI-CNTRL supports the User Information Transfer function, and the
enrolled user (cards, PINs) can be transferred from one (let’s name it Master
Unit) to another (let’s name it Accept Unit). Maximum 10pcs Accepts Units can
be transferred once.
Connection Diagram
Remarks:
- The Master Units and Accept Units must be VIS-MINI-CNTRL.
- The Master Code of the Master Unit and the Accept Unit(s) must be set to the same. Program the transfer operation on Master Unit only.
- If the Accept Unit(s) are already with the users enrolled, it will be covered after transfer. For full 1,000 users enrolled, the transfer takes 3 minutes.
Set Transferring on Master Unit:
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Set transferring | 9 6 # |
Within 3 minutes, Green LED shines, that means the users’ information has been
transferred successfully.
3. Exit Program Mode|
- User Manual
- VIS-MINI-CNTRL
- www.visionistech.com
Documents / Resources
|
VISIONIS VIS-MINI-CNTRL Door Controller for Access Control Systems with No
Software
[pdf] User Manual
VIS-MINI-CNTRL Door Controller for Access Control Systems with No Software,
VIS-MINI-CNTRL, Door Controller for Access Control Systems with No Software,
Door Controller, Controller
---|---