inventor RS-WUI-08L Desiccant Dehumidifier – Air Purifier User Manual

June 6, 2024
inventor

inventor RS-WUI-08L Desiccant Dehumidifier – Air Purifier

Dear Consumer,
Congratulations on your choice!
What distinguishes, Rise Pro dehumidifier from the rest of Inventor’s dehumidifiers series, is the unique design and the upgraded desiccant technology, that guarantee efficiency in facing humidity problems. Enjoy the ideal conditions inside your space and a healthy environment as a result of the ionizer and the ultraviolet technology that eliminate all harmful substances. Please refer to this manual, to obtain full efficiency of the dehumidifier, through the guidelines included in the following pages and make savings via clever use of this device.

SAFETY & WARNING INSTRUCTIONS

  • No children under the age of 8 should be permitted to operate this electric device. Be certain, that children, handicapped people, or people with the lack of knowledge and experience, must be supervised, depending the situation, by persons responsible for their well-being and do not undertake procedures such as the cleaning or the maintenance of this device.
  • It is important that adequate supervision is provided and no minors are left unattended with this device.
  • This dehumidifier is for domestic and small office use only. Do not use this device for commercial, industrial or marine use, and in areas with wet surfaces such as restrooms or shower rooms.
  • This device should always be kept in an upright position to avoid any damage.
  • All house exits (windows doors etc) where the dehumidifier is operating, should be shut.
  • If water leakage appears within the unit, turn the unit off and disconnect the power cord.
  • Before moving, unplug the device and manage to keep it in a vertical position in order to safely be transferred from one area to another..
  • Be sure to empty the water whenever the water tank is full or when the device will not be used for a prolonged time.
  • Always empty the water tank before storing the unit.
  • If the unit is misplaced or tipped, unplug the power cord immediately. Make sure the unit is completely dry before resuming operation..
  • Disconnect the device, if abnormal sounds, odors or smoke occur.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons to avoid a hazard. Never attempt to dismantle, repair or modify the device.
  • Do not attempt to repair, dismantle or modify this appliance. Contact your authorized service technician for repair or maintenance of this device.
  • Do not operate or stop the unit by switching the power supply on or off.
  • Do not insert any objects in the unit’s air inlet and exhaust as this may cause damage to the device.
  • Do not place heavy objects on the power cord. Make sure that the cord is not compressed.
  • Do not place cord under any obstacles (carpets rugs or runners etc). Cord should be arranged away from areas where accidental tripping may occur.
  • Do not sit or climb on the device.
  • Do not place the unit in direct sunlight or near other heating sources.
  • Do not use the unit near heat sources, chemicals, radiators, flammable materials or fire.
  • Do not remove the water tank while the device is in use.
  • Do not use the device without the filter. Dirt and lint may clog the unit thus reducing performance.
  • Do not drink or use the collected water from of the unit for any purpose.
  • Do not use the unit with wet hands.

ELECTRICAL INFORMATION

  • The nameplate, with all the electrical and technical data of this appliance, is located on the rear panel.
  • The appliance should be installed in accordance with national wiring regulations.
  • Be sure the device is grounded properly. Proper grounding is important as it minimizes the chance of electric shock or fire. The power cord is equipped with a grounding plug for protection against electric shock hazards.
  • The device must be used in a properly grounded wall socket. If the specific socket you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
  • Ensure the wall socket is still accessible after the installation of the dehumidifier.
  • Do not use extension cords or adapter plugs with this device.
  • To avoid personal injury, always disconnect the power supply of the device, before maintenance.
  • To connect or disconnect the power, grip the plug and pull it out from power socket, never pull or tug on the cord.

Power off the dehumidifier before removing the plug. Never unplug the unit before the fan has stopped blowing. Using a mechanical timer switch or an auto shut-off switch (smart socket) is not recommended. Continuous power cuts may result in decreasing the lifespan of the unit.

SOCIABLE REMARKS ENVIRONMENTAL PROTECTION

Disposal of equipment no longer used. Please follow the instructions below, when using this dehumidifier in European countries.

  • This appliance requires special treatment for disposal. In the European Union, electronic equipment must not be treated as domestic waste, but must be disposed of professionally in accordance with Directive 2002/96/EC of the European Parliament and Council of 27th January 2003 concerning old electrical and electronic equipment. The disposal of this unit should follow all legal requirements and should not be disposed as unsorted municipal waste. The hazardous substances can leak into the ground water supply thus entering the food chain, endangering your health and the environment.
  • There are several alternative solutions for disposal:
    1. Your local municipality has established free collection systems for electronic waste.
    2. Your local retailer upon purchase of a new product.
    3. The manufacturer may accept the old appliance for disposal.
    4. Old appliances sometimes contain valuable resources for scrap metal dealers.

STEPS BEFORE USE

inventor RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig
1

Installation tips

inventor RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig
2

  1. Do not block or restrict the airflow around the unit. Make sure the air inlet exhaust grills are not obstructed. Allow 30cm of clearance around the unit.
  2. Ensure the filter is clean.
  3. Place unit in vertical operating position and allow 2 hours before initial use in order to avoid malfunctions.inventor RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig 3
  4. Before the initial operation, please check, if the water level switch, located within the water bucket area, is in the right position.inventor RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig 4

GETTING TO KNOW YOUR DEHUMIDIFIER

inventor RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig
5

CONTROL PANEL FUNCTIONSinventor RS-WUI-08L Desiccant Dehumidifier - Air
Purifier fig 7

POWER
Press “POWER” button to turn the dehumidifier on or off.

  • After turning the dehumidifier OFF, the fan continues to operate for a small period of time approximately 10 minutes, so as to protect the inner components. During this operation DO NOT unplug the device. Please wait for the fan to stop operating.
  • In the event of a power failure the unit has an Auto Restart function. Once the power is restored after a power failure, the appliance will automatically restart to operate at the selected settings prior to the power failure expect the timer and child lock setting which will be both deactivated.

TIMER

  • Once the desired hour(s) selected, wait for 3 seconds without pressing anything and the indication of timer will appear on the digital display to confirm that timer is activated.
  • In case of a power failure the timer setting will be automatically deactivated.

CHILD LOCK
Press the “TIMER” button continuously for 3 seconds to activate or deactivate the child lock function. The indicator will remain steadily on the display informing that child lock is active.

  • Under Child Lock: All control buttons are deactivated and the unit will make a beeping sound each time a button is pressed.
  • In case of a power failure the child lock setting will be automatically deactivated.

HUMIDITY CONTROL
Humidity Set Control Button. The humidity level can be set within a range of 40% RH (Relative Humidity) to 80% RH (Relative Humidity) and CO in 5% increments each time the relative button is pressed. The desired level of humidity will appear on the led display.

  • By selecting the continuous mode “CO” the dehumidifier will operate continuously extracting humidity. During CO mode the dehumidifier will keep operating until the water tank is full, disregarding the relative humidity of the room.

HUMIDITY LIGHT INDICATOR
The humidity light indicator will be continuously on under normal mode to inform you about the level of ambient humidity inside the room.

  • Blue color for relative humidity under 55%
  • Yellow color for relative humidity between 56% and 79%
  • Red color for relative humidity over 80%

MODE
By pressing the ‘’MODE’’ button you can select between four different modes: Normal, ECO, Turbo and Smart Dehumidification (SMD).

Normal Mode – Under Normal mode the dehumidifier is operating in medium fan speed to reach the set humidity level. The number (2) will appear on the led display to indicate your mode choice. When the set humidity is reached, the Energy Savings function is automatically activated. After the predetermined timeframe and if the humidity levels have increased, the device will resume dehumidification. It is a mode suggested for daily operation.

ECO Mode – Under ECO mode the dehumidifier is operating in low fan speed to reach the set humidity level. In this mode the consumption is reduced to half. The number (1) will appear on the led display to indicate your mode choice. When the set humidity is reached, the Energy Savings function is automatically activated. After the predetermined timeframe and if the humidity levels have increased, the device will resume dehumidification.

  • Use this mode to achieve better energy savings.

Turbo Mode – Under Turbo mode the dehumidifier is operating in high fan speed to reach the set humidity level. The number (3) will appear on the led display to indicate your mode choice. When the set humidity is reached, the Energy Savings function is automatically activated. After the predetermined timeframe and if the humidity levels have increased, the device will resume dehumidification.

This mode is suggested for situations with severe humidity, where big amount of water needs to be distracted such us flooded rooms, for rooms that have not been used for and long time, but it can only be selected for clothes drying. Drying clothes function: Select the Turbo mode and the continuous dehumidification to achieve the better results when you decide to dry your clothes.

  • Position the dehumidifier in a small sized room along with your clothes horse. Keep doors shut, and your clothes will dry up in no time!
  • For optimal results manual wringing of the clothes is suggested.
  • Allow a 30-50cm distance between the unit and the clothes.

Smart Dehumidification mode (SMD) – Under SMD mode the dehumidifier is operating according to the existing temperature and ambient humidity conditions inside the room. The letter (A) will appear on the led display to indicate your mode choice. The ideal humidity level will be automatically set between 45% and 55% depending on the room temperature. The higher the room temperature, the lower will be the set humidity level in order to achieve ideal leaving conditions. The fan speed will be also automatically adjusted in low, middle and high speed, depending on difference between the ambient humidity and the set humidity. The bigger the difference the higher will be the fan speed.

SWING
Press the ‘’SWING LOUVER’’ button to activate/deactivate this feature. By pressing the button once, the swing louver operates in such a manner allowing a multi-directional air stream. By pressing the button a second time, the louver can be stopped at a desired angle. This option is selected for a direct air flow ideal for drying clothes.

IONIZER
Press the ‘’IONIZER’’ button to switch on/off the ionizer. Ions will be released in the air to purify it and remove unpleasant and unhealthy particles. The indicator will appear on the led display.

ULTRAVIOLET TYPE C
Long press the ‘’IONIZER’’ button for 3 seconds to switch on/off the function of the ultraviolet led type C (UVC). The UVC led will help eliminate microorganisms such as germs, viruses, bacteria and fungi. The indicator will appear on the led display.

FAN ONLY
Long press the ‘’MODE’’ and ‘’IONIZER’’ buttons for 3 seconds to initiate the Fan only function. Under Fan only you can select the fan speed between low, medium or high by pressing the mode button . Turn on the Ionizer and the UVC function to achieve great air purification results inside the room.

  • Under fan only function, no dehumidification is taking place and the humidity cannot be adjusted by the relevant button on the control panel.

Wi-Fi
Long press the ‘’SWING LOUVER’’ button for 3 seconds to active the Wi-Fi pairing process. The indicator will appear on the led display. You can operate the dehumidifier remotely using the application Inventor Control.

MUTE MODE
Long press the ‘’ SWING LOUVER’’ and ‘’TIMER’’ buttons for 3 seconds to mute and unmute the sound of the buttons of the control panel.

  • While in mute mode the sound alarms will be still activated.
ON-DISPLAY INDICATORS

P2- FULL WATER TANK
When the water tank is full, removed or not placed correctly, the indication P2 will appear on the digital display followed by a beeping sound. While the indicator P2 is on the dehumidifier will be on stand-by until water tank is placed correctly or emptied.

P3 – FILTER CLEAN REMINDER
When the air filter requires maintenance, the indication P3 will appear on the digital display. The reminder is set to appear after 360 working hours of the dehumidifier. Carefully remove the filter, rinse it with water and let it dry completely before using it again. To reset the reminder long press the ‘’HUMIDITY’’ button for 3 seconds.

Internal Over Heating Protection
During operation, malfunctions may occur if the air intake or exhaust are obstructed or blocked by objects. This can cause high internal temperatures and the appliance will automatically shut down. Unplug the device immediately and resume operation after 5 minutes.

Tipping Protection
In order to avoid overheating in the event of tipping, the device is equipped with a tipping switch that automatically shuts down the device.

WATER TANK & DRAIN HOSE

There are two ways to remove collected water. Before proceeding, ensure that you have switched off and unplugged the device.

  1. Using the water bucket
    When the water tank is full, the alarm will beep and the Water Full indicator will turn on.

    • Slowly remove the bucket. Grip the handle with caution, and carefully pull outwards so the water does not overflow. Do not place the tank on the floor because the bottom of the tank is uneven. Doing so the tank will fall and the water will be spilled on the floor.
    • Empty the water from the tank and place it again in to the device. The water tank, must be securely and properly placed, for the dehumidifier to operate.
    • When the water tank is re-installed the unit will automatically restart.
    • When you remove the tank, do not touch any parts inside the unit, as you may damage the device.
    • Be sure to gently place the tank into the dehumidifier.
    • Do not drink or use the collected water from the device.
    • Wipe any excess water on, or in, the unit when removing the tank.
  2. Continuous draining
    Water automatically can be emptied into a floor drain by attaching the unit with a water hose.

    • Remove the water tank and attach the drain hose to a suitable drainage facility. Make sure the hose is attached securely to avoid any leaks and place it as deep as possible to ensure the right drainage.
    • The dehumidifier should be placed on a flat surface in an upright position.
    • Place the end of the hose into the drain and make sure that the water flows naturally. For correct drainage, make sure the hose stays below the level of the drain hose outlet.inventor RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig 8inventor RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig 9

When the continuous drainage feature is not being used, remove the drain hose from the drain hose outlet.

Before performing any maintenance or cleaning of the dehumidifier, make sure that it is unplugged.

Cleaning the filter:
Use water and mild detergent to clean the dehumidifier.

  • Do not use abrasive cleaning agents or solvents; use a brush or vacuum attachments for cleaning
  • Do not use a dishwasher to clean the filter.
  • Do not apply any water directly on or into the device while cleaning, as it may cause rust, insulation deterioration or electrical shock.
  • Allow the filter to completely dry before re-installing.inventor RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig 10

Cleaning the tank:
Partially fill the tank with clean water adding a minimal amount of mild detergent. Clean thoroughly empty and rinse.

  • Clean the tank every 2 weeks to prevent mold, mildew and bacteria growth.
  • After cleaning, make sure the tank is placed back securely for the dehumidifier to operate.

When unit is inactive for an extended period of time please make sure you follow the instructions below, for an appropriate storage of your appliance:

  • Turn unit off allowing one day before storage.
  • Remove the drain hose (if attached).
  • Clean the removable parts of the device, water bucket and air filter.
  • Cover the device.
  • Store the dehumidifier. in upright position, in a dry, well ventilated area and avoid direct sunlight.

FREQUENTLY ASKED QUESTIONS & TROUBLESHOOTING

Does the Zeolite need replacing?
No there is no need for replacement. The Zeolite is regenerated within the dehumidifier and this will last for many years.

Are dehumidifiers expensive to run?
For the first month upon its initial operation, the dehumidifier operates at its maximum in order to calibrate in its working environment. As time passes, this will gradually reduce, since the dehumidifier will be controlled via its humidistat. In regards to damp houses, the use of a dehumidifier may lower your central billing costs significantly.

Do desiccant dehumidifiers generate an unpleasant smell?
During the first days of usage and periodically afterwards you might notice a smell coming from the dehumidifier. This is caused by the Zeolite desiccant material and is not a sign that the dehumidifier is not working properly nor is it harmful to humans or pets. The smell occurs because the Zeolite absorbs odors from items like cigarettes, cosmetics, hair sprays, building materials and new furniture, and as the desiccant is heated the smell is discharged into the room. You can clear it by running the dehumidifier in a separate space like a garage or – if it is dry – outside.

Where would it be better to place the dehumidifier?
For optimal results, it is suggested to place the dehumidifier in a central area, like a hallway. Leave the doors open and the moisture will migrate naturally towards the device to be processed.

Can we replace the filter with one of other type like HEPA filter etc.?
No, the filter can’t be replaced.

Which is the appropriate room humidity level?
The suggested humidity range fluctuates between 40% and 60%. This level of an average humidity ensures the greatest comfort for you and your family, preventing allergies or diseases, and keeps your home healthy and well maintained, in terms of plasterboards, dye exfoliation, wood furniture and any other equipment or material that is susceptible to the harmful consequences of extremely high humidity conditions.

Why there is still condensation from the windows, even by using the dehumidifier?
When the room reaches the preferred humidity level, there is a possibility of humidity appearance on windows. This happens due to the temperature difference of the room’s and external ambient temperature. Keep running the dehumidifier and when the air temperature outside increases the windows should clear of condensation.

The dehumidifier is not a heating device. What could be the cause of warm air being extracted?
The desiccant dehumidifier Rise Pro, operates with an electrical resistance that warms up the desiccant material. As a result, the temperature of the outgoing air has been increased to 10°C comparing to the room’s temperature. This doesn’t denote in any case that this device can be used as a heating appliance.

Why the dehumidifier does not collect water inside the water tank during the operation?
The dehumidifier has a separate FAN ONLY function, during which no dehumidification takes place. Please check if you have selected this mode and try to adjust the humidity levels. If the relevant button beeps without any change, then try to turn off the FAN ONLY function following the steps from this user’s manual.

The unit does not start

  • Make sure the dehumidifier’s plug is placed completely into the socket.
  • Check the house fuse/circuit breaker box.
  • Check whether the power cord is damaged.
  • Check the water bucket, if it is full, empty it.
  • Check if the dehumidifier has reached its preset level.
  • Make sure the water bucket is positioned properly.
  • Room temperature is lower or higher than the advised operational range.
  • Check whether the humidity level has been set in high levels.

Dehumidifier does not dry the air as efficient

  • Make sure that the dehumidifier has been operating enough time to remove the moisture.
  • Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier.
  • The humidity selector may not be set low enough.
  • Make sure you have cleaned the filter as suggested. Clogged filter may result in reduced performance.
  • All house exits (windows doors etc) where the dehumidifier is operating, should be shut.
  • Room temperature is below the advised operational range.
  • There is a kerosene heater or something giving off water vapor in the room.
  • The room that the device is placed is bigger than suggested.
  • The humidity level is too high.

The unit makes a loud noise when operating

  • The air filter is clogged.
  • The device is titled instead of being in an upright position.
  • The floor surface is not flat.

During the use of the drain hose, you may find water inside the water tank

  • Check that the drain hose has been correctly placed.
  • The drain hose has been blocked or damaged.

Error codes

  • C1: NTC1 is open cut or short cut
  • C2: NTC 2 is open cut or short cut
  • C3: NTC1 &NTC 2 are open cut or short cut
  • C4: Sync motor failure
  • 88: Temperature and humidity sensor failure
  • P2: Water tank full
  • P3: Pre-filter clean reminder

All the pictures in the manual are for explanatory purposes only. The actual shape of the unit you purchased may be slightly different, but the operations and functions are the same. The company may not be held responsible for any misprinted information. The design and the specifications of the product for reasons, such as product improvement, are subject to change without any prior notice. Please consult with the manufacturer at +30 211 300 3300 or with the Sales agency for further details. Any future updates to the manual will be uploaded to the service website, and it is advised to always check for the latest version.

ACTIVATE YOUR WARRANTY

Follow the next quick steps to activate your warranty:

STEP 1: Visit our website via the link:
https://www.inventorappliances.com/warranty-card

STEP 2: Fill in the obligatory fields as requested in the “Owner’s details” and “Unit’s details”:inventor RS-WUI-08L Desiccant Dehumidifier -
Air Purifier fig 11

STEP 3: Click SEND button at the end of the submission form:inventor
RS-WUI-08L Desiccant Dehumidifier - Air Purifier fig 12

STEP 4: Wait for the confirmation email you will receive at the email address you have filled in. Please also check your spam folder.
STEP 5: Inventor warranty is now valid!

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals