westermo 12A Series 12 Port Ethernet M12 Switches User Guide
General Information
Legal Information The contents of this document are provided “as is”.
Except as required by applicable law, no warranties of any kind are made in
relation to the accuracy and reliability or contents of this document, either
expressed or implied, including but not limited to the implied warranties of
merchantability and fitness for a particular purpose. Westermo reserves the
right to revise this document or withdraw it at any time without prior
notice.Under no circumstances shall Westermo be responsible for any loss of
data or income or any special, incidental, and consequential or indirect
damages howsoever caused.More information about Westermo can be found at
www.westermo.com.
About This Guide This guide is intended for installation engineers and
users of the Westermo products.It includes information on safety and
regulations, a product description, installation instructions and technical
specifications.
Software Tools Related software tools are available at
www.westermo.com/support/software-tools.
License and Copyright for Included FLOSS This product includes software
developed by third parties, including Free/Libre Open Source Software (FLOSS).
The specific license terms and copyright associated with the software are
included in each software package respectively. Please visit the product web
page for more information.Upon request, the applicable source code will be
provided. A nominal fee may be charged to cover shipping and media. Please
direct any source code request to your normal sales or support channel.
WeOS Management Guide This product runs WeOS 4 (Westermo Operating
System). Instructions for quick start, configuration, factory reset and use of
USB port are found in the WeOS Management Guide at
www.westermo.com.
Safety and Regulations
Warning Levels
Safety Information
Before installation:
Read this manual completely and gather all information available on the
product. Make sure it is fully understood. Check that your application does
not exceed the safe operating specifications for the product. Warning signs
are provided to prevent personal injuries and/or damages to the product. The
following levels are used:
SAFETY DURING INSTALLATION
The product must be installed and operated by qualified service personnel and
installed into an apparatus cabinet or similar, where access is restricted to
service personnel only.
Refer to chapter Compliance Information to see the required level of qualified
service personnel according to safety standards.During installation, ensure a
protective earthing conductor is first connected to the protective earthing
terminal (only valid for metallic housings). Westermo recommends a cross-
sectional area of at least 4 mm2.
Note that this product can be connected to two different power sources. Upon
removal of the product, ensure that the protective earthing conductor is
disconnected last.
HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur when connected
to a power supply.
PROTECTIVE FUSE The power supply wiring must be sufficiently fused. The fuse must be IEC 60127 certified and rated for T1.6 A and 250 V.It must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.This product has no internal fuse and should be connected via an external fuse for protection.
REDUCE THE RISK OF FIRE To reduce the risk of fire, use only telecommunication line cords with a cable diameter of AWG 26 or larger. Regarding power cable dimensions, see chapter Interface Specifications.
CABLE TEMPERATURE RATING FOR FIELD TERMINAL WIRES There may be a requirement on the minimum temperature rating of the cable to be connected to the field wiring terminals, see chapter Interface Specifications.
ELECTROSTATIC DISCHARGE (ESD) Prevent electrostatic discharge damage to internal electronic parts by discharging your body to a grounding point (e.g. use a wrist strap).
HOT SURFACE Be aware that the surface of this product may become hot. When it is operated at high temperatures, the external surface may exceed Touch Temperature Limit according to the product’s relevant electrical safety standard.
NOTE – MECHANICAL FORCE ON VENTILATION MEMBRANE Do not cover or bring mechanical force to the ventilation membrane on the back of the product.
Care Recommendations Follow the care recommendations below to maintain full operation of the product and to fulfill the warranty obligations:
- Do not drop, knock or shake the product. Rough handling above the specification may cause damage to internal circuit boards.
- Use a dry or slightly water-damp cloth to clean the product. Do not use harsh chemicals, cleaning solvents or strong detergents.
- Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired.If the product is not working properly, contact the place of purchase, the nearest Westermo distributor office or Westermo technical support.
Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment.By ensuring the product is disposed of correctly, you will help to reduce hazardous substances and prevent potential negative consequences to both the environment and human health, which could be caused by inappropriate disposal.
Compliance Information
Agency Approvals and Standards Compliance
Type | Approval/Compliance |
---|---|
Climate | • EN 50155 class OT4 / IEC 60571 class TX, Railway applications – |
Electronic equipment used on rolling stock
• IEEE 1478 class 1, condition E4 (incl Salt Mist), Environmental conditions for transit rail car electronic equipment
EMC| • EN/IEC 61000-6-2, Immunity industrial environments
• EN/IEC 61000-6-4, Emission industrial environments
• EN 50121-4/IEC 62236-4, Railway signalling and telecommunications apparatus
• EN 50121-3-2/IEC 62236-3-2 Railway applications – Rolling stock – apparatus
• Tested and verified for Class S1, DB EMC Regulation 06, Commodity team Radio compatibility in VDB Rev 1.0 (Shunting Radio)
• Tested and verified for FCC part 15b class A (CFR 47)
• E-Mark, Road Vehicles, E1 10R-058547
Mechanical (Shock and vibration)| • EN 61373 category 1, class A and B
• EN 60068-2-27 20 g, 11 ms and 100 g, 6 ms
Insulation (Coordination and test)| • EN 50124-1, Railway applications – Insulation coordination
• EN 50155/IEC 60571, Railway applications – Electronic equipment used on rolling stock
Fire protection| • EN 45545-2, Fire protection on railway vehicles
• NFPA 130, Fire protection for fixed guideway transit and passenger rail system
Software| • EN 50657:2017 Software Onboard Rolling Stock (Basic Integrity)
Safety| • EN/IEC/UL 61010-1, -2-201, Safety requirements for electrical
equipment for measurement, control, and laboratory use
EN/IEC/UL 61010-2-201 Notice
This product has been tested and found compliant to EN/IEC/UL 61010-2-201,
Safety requirements for electrical equipment for measurement, control, and
laboratory use. In accordance with the definitions of the standard, this
product shall be handled by skilled service personnel.
FCC Part 15.105 Class A Notice
This product has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules.These limits are designed
to provide reasonable protection against harmful interference when the product
is operated in a commercial environment.This product generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance
with the user manual, may cause harmful interference to radio communications.
Operation of this product in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at the users own expense.
Simplified Declaration of Conformity
Hereby, Westermo declares that this product is in compliance with applicable
EU directives and UK legislations. The full declaration of conformity and
other detailed information is available at www.westermo.com/support/product-
support.
Product Description
The Viper-12A series consists of managed 12 port routing switches optimised
for the needs of the railway rolling stock market. Gbps ports cope with high
bandwidth devices such as access points and NVRs (Network Video Recorders).The
Viper-12A series is designed to withstand the tough environment on-board
trains, exposing the switch to constant vibration, extreme temperatures,
humidity and a demanding electrical environment.A GORE-TEX® membrane prevents
internal condensation. Threading integrated in chassis provides for additional
vibration resistance. High-level isolation between all interfaces enables
direct connectivity to vehicle auxiliary power and protects against
overvoltage and flashover. IP67 protection prevents ingress of water and dust.
An overall optimised design results in an extremely compact package in
combination with very high MTBF for easy integration and low lifecycle
cost.Thorough type testing at independent ISO/IEC 17025 and ILAC MRA certified
labs, accredited to a wide range of standards, show that the Viper series
fulfills EN 50155 and other requirements. The state-of-the-art Westermo
production facility ensures the quality of each individual unit, e.g. through
temperature cycling burn-in testing.The WeOS operating system offers an
extensive suite of IP networking features for resilient and flexible networks,
e.g. the FRNT ring protocol with very fast failover. The powerful layer 3
routing capability is very useful for separating networks in complex
applications. The backup device accessory matches the Viper in robustness and
offers easy configuration update and backup.Meeting the requirements of the
railcar market, the Viper-12A series is very well suited for deployment in any
other application with severe operating conditions and tough environments, for
instance in the mining industry.
Available Models All switches are managed. Viper x12A is used when
referring to both models 112A and 212A.
Art. no. | Model | Software | Gbps ports |
---|---|---|---|
3635-0010 | Viper-112A | L2 | – |
3635-0310 | Viper-112A-T3G | L2 | 3 |
3635-0610 | Viper-112A-T5G | L2 | 5 |
3635-0020 | Viper-212A | L3 | – |
3635-0320 | Viper-212A-T3G | L3 | 3 |
3635-0620 | Viper-212A-T5G | L3 | 5 |
NOTE – MECHANICAL FORCE ON VENTILATION MEMBRANE
Do not cover or bring mechanical force to the ventilation membrane on the back
of the product.
Hardware Overview
No. | Description | No. | Description |
---|---|---|---|
1 | LED indicator | 2 | 100 Mbps port |
3 | Gbps port | 4 | Power connection |
5 | Console port | 6 | Protective earth connection |
7 | USB port |
Connector Pinout
Pin no. | Signal | Illustration |
---|---|---|
1 | +DC1 |
2| +DC2
3| -COM
4| -COM
Viper-x12A supports redundant power connection. The positive inputs are +DC1
and +DC2. The negative input for both supplies is -COM
Pin no.| Signal| Illustration
---|---|---
1| NCa|
2| TX
3| RX
4| NCa
5| GND
Pin no.| Signal| Illustration
---|---|---
1| DN|
2| VBUS
3| NCa
4| DC
5| GND
Pin no.| Signal| Illustration
---|---|---
1| TD+|
2| RD+
3| TD-
4| RD-
MDI, MDI-X and auto MDI/MDI-X modes are supported. The table shows signals in
MDI mode.
Pin no.| Signal| Illustration
---|---|---
1| DA+| __
__
2| DA-
3| DB+
4| DB-
5| DD+
6| DD-
7| DC-
8| DC+
LED Indicators
LED | Status | Description |
---|---|---|
ON | OFF | Product has no power |
GREEN | All OK, no alarm condition | |
RED | Alarm condition, or until product has started up. (Alarm conditions are |
configurable, see WeOS Management Guide )
BLINK| Location indicator (“Here I am!”). Activated when connected to WeConfig
tool, or upon request from web or/and CLI. RED BLINK during boot indicates
pending cable factory reset.
RSTP| OFF| RSTP disabled
GREEN| RSTP enabled
BLINK| Product selected as RSTP/STP root switch
FRNT| OFF| FRNT disabled
GREEN| FRNT OK
RED| FRNT error
BLINK| Product configured as FRNT focal point
DC| OFF| Product has no power
GREEN| Power OK on DC1 and DC2
RED| Power failure on DC1 or DC2
X1 to X12| OFF| No link
GREEN| Link established
GREEN FLASH| Data traffic indication
YELLOW| Port alarm, or port is set in blocking state by link redundancy
protocol
Dimensions
Dimensions are stated in mm.
Installation
Wall Mounting The product can be wall mounted vertically or horizontally. There are four pieces of 7 mm bores for this. Use four M5, M6 or 1/4″ screws with 12 mm washers on a flat and stable surface.
Figure 5. Wall mounting
Protective Earth Connection
For correct function, the earth connection needs to be properly connected to a
designated PE rail. See the figure below.
Connection of Cables Recommended tightening torque for the M12 connectors is 0.6 Nm. All M12 connections are screw connections.When connecting the power cable, ensure that the pins are connected correctly before tightening the power cable to the unit.
PROTECTIVE FUSE The power supply wiring must be sufficiently fused. The fuse must be IEC 60127 certified and rated for T1.6 A and 250 V.It must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations.This product has no internal fuse and should be connected via an external fuse for protection.
NOTE – UNUSED CONNECTORS Unused connectors must be covered by a protective cap (delivered with the product), tightened to the specified torque in order to fulfill the specified ingress protection code.
Cooling This product relies on convection cooling. Make sure that it is
installed so that the ambient temperature is within the specified temperature
range. Avoid obstruction of the airflow around the product.
Replacement of Product Disconnect all cables and unscrew the product from
the wall. Mount the replacement product and reconnect all cables, observing
the instructions in Connection of Cables [18]. For easy replication of the
configuration of the original product, it is recommended to have the Westermo
USB plug permanently connected to the USB port and move it over to the
replacement product before it is powered up.MTTR (Mean Time To Repair), i.e.
time for replacement of product is: < 10 minutes.
HOT SURFACE
Be aware that the surface of this product may become hot. When it is operated
at high temperatures, the external surface may exceed Touch Temperature Limit
according to the product’s relevant electrical safety standard.
EN 45545-2 Mounting Notes
Two product can be mounted together and as a single interior non-listed group
in the sense of EN 45545-2 definitions. For multiple product, the spacing
requirements for interior non-listed groups must be met.
Specifications
Interface Specifications
DC, Power port
Rated voltage a| 24 to 110 VDC
Operating voltage b| 16.8 to 143 VDC (14.4 VDC to 100 ms and 154 VDC
for 1 s)
Rated current| Max 580 mA at 24 VDC, max 140 mA at 110 VDC
Rated frequency| DC
Inrush current| 80 mA²s at 24 VDC, 140 mA²s at 110 VDC
Startup current| Max 840 mA at 16.8 VDC
Polarity| Reverse polarity protected
Redundant power input| Yes
Isolation| To all other ports
Circuit type| Secondary circuit hazardous voltage, OVC II
Connector| 4-pin, male, M12, A-coded, recommended Westermo cables:
3146-1106 for 1.5 m
3146-1107 for 5 m
Cable size| M12, recommended power cable area 0.5 mm² (minimum 0.25 mm²), which correlates to AWG 21 or larger
Cable dimensions depend on choice of M12 connector
Cable temperature rating| For minimum temperature rating of the cable to
be connected to the field wiring terminals: -40 to +70 °C
100 Mbps ports a
Electrical specification| IEEE std 802.3
Data rate| 10 Mbps, 100 Mbps, manual or auto
Duplex| Full or half, manual or auto
Circuit type| TNV-1
Transmission range| Up to 150 m with CAT5e cable or better
Isolation| To all other ports
Connector| 4-pin, female, M12, D-coded, auto MDI/MDI-X, recommended
Westermo cables:
3146-1100 M12-M12 – 1 m
3146-1101 M12-M12 – 5 m
3146-1103 RJ45-M12 – 1 m
3146-1104 RJ45-M12 – 5 m
Cabling| Shielded cable CAT5e or better is recommended
Conductive chassis| Yes
FRNT reconfiguration time| Typically below 20 ms| Gbps
ports a
Electrical specification| IEEE std 802.3
Data rate| 10 Mbps, 100 Mbps, 1000 Mbps, manual or auto
Circuit type| TNV-1
Transmission range| Up to 150 m with CAT5e cable or better
Isolation| To all other ports
Connector| 8-pin, female, M12, X-coded
Cabling| Shielded cable CAT5e or better is recommended
Conductive chassis| Yes
FRNT reconfiguration time| Typically below 20 ms
USB port
Electrical specification| USB 2.0 host interface
Data rate| Up to 480 Mbps (high-speed mode)
Maximum supply current| 500 mA
Circuit type| SELV
Isolation| To all Ethernet and DC ports
No isolation to CON or protective earth
Connector| 5-pin, female, M12, A-coded, recommended Westermo USB plug
3641-0190
Console port
Electrical specification| RS-232
Data rate| 115.2 kbit/s
Data format| 8 data bits, no parity, 1 stop bit, no flow control
Circuit type| SELV
Isolation| To all Ethernet and DC ports
No isolation to USB or protective earth
Connector| 5-pin, female, M12, B-coded, recommended Westermo cables: 1211-2215 (serial port) or 1211-4073 (USB)
Type Tests and Environmental Conditions
Environmental phenomena| Basic standard| Description|
Test levels
---|---|---|---
ESD| EN 61000-4-2| Enclosure| Contact: ±6 kV Air: ±8 kV
Fast transients| EN 61000-4-4| Power port| ± 2 kV
Signal ports
Earth port
Surge| EN 61000-4-5| Power port| L-E: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs
L-E: ± 0.5 kV, 12 Ω, 9 µF, 1.2/50 µs L-L: ± 2 kV, 42 Ω, 0.5 µF, 1.2/50 µs L-L:
± 0.5 kV, 2 Ω, 18 µF, 1.2/50 µs
Ethernet port| L-E: ± 2 kV, 2 Ω
Pulsed magnetic field| EN 61000-4-9| Enclosure| 300 A/m
Radiated RF immunity| EN 61000-4-3| Enclosure| 20 V/m at (80 MHz
to 2 GHz)
10 V/m at (2-6 GHz)
1 kHz sine, 80% AM
Conducted RF immunity| EN 61000-4-6| Power port| 10 V, 80% AM, 1
kHz; (0.15-80) MHz
Ethernet ports
Earth port
Radiated RF emission| CISPR 16-2-3| Enclosure| EN 61000-6-4 (30-6000
MHz)
ANSI C63,4 (FCC Part 15)| EN 61000-6-4 (30-6500 MHz)
Conducted RF emission| CISPR 16-2-1| Power port| EN 61000-6-4
Ethernet ports| EN 61000-6-3
Dielectric strength| EN 60950-1| Power port to all other ports| 2250
VDC, 1 min
Ethernet ports to all other ports| 2250 VDC, 1 mina
Gbps Ethernet ports to all other ports| 2250 VDC, 1 mina
Environmental phenomena| Basic standard| Description|
Test levels
---|---|---|---
Temperatures| EN 60068-2-1
EN 60068-2-2
| Operational| -40 to +70°C (-40 to +158°F)ab
Storage and transport| -55 to +85°C (-67 to +185°F)
Humidity| EN 60068-2-30| Operational| 5-95% relative humidity
Storage and transport
Altitude| | Operational| 2000 m
Service life| | Operational| 20 years according to IEC/TR 62380
MTBF| 1: MIL-217F2, GB, 25°C (+77°F)
2: IEC 62380
| | Viper-x12A: 1: 557,000 h
Viper-x12A-T3G: 1: 549,000 h, 2: 561,000 h
Viper-x12A-T5G: 1: 544,000 h
Vibration| IEC 60068-2-6
(sine)
| Operational| 2 g rms 5-500 Hz, 5 sweeps
IEC
60068-2-64
(random)
| Non-operational long life simulation| 11.44 m/s² rms 5-150 Hz, 5 hours
2.3 m/s² rms 5-2000 Hz, 5 hours
Shock| IEC
60068-2-27
| Operational| 10 g, 30 ms, half sine
20 g, 11 ms, saw tooth
100 g, 6 ms, half sine
Weight| | | 1.4 kg
Degree of protection| EN 60529| Enclosure| IP67
Cooling| | | Convection
Overvoltage category| EN/IEC/UL 61010-1| | OVC II
Pollution degree| EN/IEC/UL 61010-1| | PD3 macro environment and PD2
micro environmentc
EN 50124-1| | PD2
Location| EN/IEC/UL 61010-1| | Outdoor, wet locations
IEEE 1478| | Class 1, condition E4. Indoor
Revision Notes
Revision | Date | Change description |
---|---|---|
Rev. L | 2022-01 | 2.2 Safety Information updated (Warning – Safety during |
installation),
2.5.1. Agency Approvals and Standards Compliance (Software plus Safety added), 2.5.2 EN/IEC/UL 61010-2-210 Notice added, 5.2 Type Tests and Environmental Conditions updated (UL added to EN/IEC 61010-1)
Rev. K| 2021-12| 5.1 Interface Specification updated (DC Power port; operating
voltage)
Rev. J| 2021-05| Westermo logo updated, blue product illustrations throughout
the user guide, 2.2 Safety Information – various warnings updated in
accordance with General and Information Safety manual, 2.3 Care
Recommendations, text updated, old chapter 2.4 Maintenance deleted, 2.5.1.
Agency Approvals and Standards Compliance updated, 2.5.3 Simplified
Declaration of Conformity; text and figure updated, 3.1. Product Description
updated,
3.4. Connector Pinout, illustration for table 5 updated, 3.6. Dimensions, illustration updated, 4.2. Earth connection chapter added, 5.1. Interface Specifications updated (all tables), 5.2 Type Tests and Environmental Conditions updated (Altitude updated, Enclosure deleted, Overvoltage category added, Pollution degree added and Location added).
Rev. I| 2020-01| 2.6.1 Agency Approvals and Standards Compliance – references to
SBB requirements and ÖBB removed, 5.1 Interface Specifications (rated current) updated.
Rev. H| 2019-09| 5.1 Interface specification updated with new inrush current
value.
Rev. G| 2019-06| Front page updated, “unit” changed to “product” throughout
the user guide, 1.3 Software Tools text updated, 2.2 Safety Information:
Notice
– Mechanical force on ventilation membrane new information, 2.3 Care Recommendations text updated, 2.6.1 Agency Approvals and Standards Compliance updated (E-mark), 4.4 Replacement of Product text updated
Rev. F| 2018-12| 2.2 Safety Information with specific symbol for Caution – Hot surface, and text in Notice – Connect external fuse updated, 2.5 Environmental Protection updated to Product disposal, 2.6.1 Agency Approvals
table updated, 2.6.3 Declaration of Conformity updated to Simplified Declaration of Conformity, 3.3 Hardware Overview table updated, 4.2 updated with Notice – Connect external fuse, 4.4 symbol for Caution
– Hot surface updated, 5.1 Interface specifications updated with inrush current, 5.2 Type Tests and Environmental Conditions – enclosure updated, end page updated
Rev. E| 2017-09| 2.1. Definition of personal injury at Caution level updated,
2.6.1 Mechanical data updated, chapter 3.6 updated, 5.1 Interface
Specifications updated – Transmission range for 100 Mbps ports and Gbps ports
changed to 150 m, 5.2 Type Tests and Environmental Conditions – Enclosure
updated, Radiated + Conducted RF emission updated
Rev. D| 2017-07| New layout for user guide with rearranged chapters, chapter 1
text updated, new chapter 1.5, chapter 2.1 new defining Warning levels,
chapter 2.6.1 Agency approvals updated (Shock and NFPA 130), updated text in
chapter 3.1, “±” removed from “±2250 VDC” throughout the user
Revision| Date| Change description
---|---|---
| | guide, radiated RF immunity, service life, shock and operating
temperature updated in chapter 5.2. Old chapters Getting started,
Configuration, Reference documents and Cable factory reset are deleted.
References
- comwestermo.com
- Westermo ᐅ Robust and Secure Industrial Networking Solutions
- Product support, user guides and software downloads ᐅ Westermo
- Legacy Software Tools ᐅ Westermo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>