Stylish and simple to use, with a clear LED status indicator, the Quantum dial thermostat gives you easy and accurate control. All this, plus silent switching and a modern, compact design.
Thermostat mounting
Install the Quantum dial thermostat approximately 1.5m above the floor level.
It should be mounted in a location where the thermostat is easily accessible
and away from direct sunlight.
For wall mounting, mark the correct position on the wall then mount the rear
case to the wall.
Terminal connection
Note: You can wire the thermostat directly to the Quantum wiring centre.
Switching bridges
Quantum dial thermostat switching bridges
Switch| Feature| ON| OFF
VP| Valve protection feature| |
PWM| Pulse-Width-Modulation| |
| NSB Function (2° or 4°)| 2°C
| 4°C
Different features of the Quantum dial thermostat can be switched ON or OFF with the jumpers.
Jumpers
The jumpers from 1 to 5 represent the number of actuators that you can connect to the thermostat.
After the actuators are mounted, move the jumper to the correct number of actuators.
Depending on the amount of actuators used, you need to change the jumper position accordingly to compensate for the power consumption.
Thermostat functions
NSB (Night Setback) Function
0V = NSB OFF
230V = NSB ON
The NSB signal is activated every 1 second. When the signal is received the
setpoint temperature will be set at ±2°C or ±4°C.
Protection function
Heat cut off at high temperature:
When the room temperature is over 36°C, all heating outputs will be turned
off.
Valve protection:
Set the jumper to ‘ON’ to disable the function or on ‘OFF’ to enable it. Turn
on the valve for 5 minutes every week to prevent damage to the valve.
Sensor malfunction:
If the temperature sensor or temperature sensor compensation is open, the LED
will flash alternate BLUE / RED.
Product compliance and safety
Product compliance
This product complies with the essential requirements and other relevant provisions of Directives 2014/30/ EU, 2014/35/EU, 2014/53/EU and 2011/65/EU.
Safety information
Use in accordance with the regulations. Indoor use only. Keep your device
completely dry.
Disconnect your device before cleaning it with a dry cloth.
Note: Always isolate the AC mains supply before installing or working on any components that require 230 VAC supply