HIKVISION DS-PDP15P-EG2-WB/WE Wireless PIR Detector User Manual
- June 6, 2024
- Hikvision
Table of Contents
DS-PDP15P-EG2-WB/WE
Wireless PIR Detector
50131-1:2006+A1:2009+A2:2017
50131-2-2:2017
50131-5-3:2017
Security Grade(SG) 2
Environmental Class(EC) II
Certified by Telefication
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual, The Manual includes instructions for using and managing the
Product. Pictures, charts, images and all other information hereinafter are
for description and explanation only. The information contained in the Manual
is subject to change, without notice, due to firmware updates or other
reasons. Please find the latest version of this Manual at the Hikvision
website (https://www.hikvision.com/). Please use this Manual with the
guidance and assistance of professionals trained in supporting the Product.
HIKVISION and other Hikvision trademarks and logos are the properties of
Hikvision in various jurisdictions. Other trademarks and logos mentioned are
the properties of their respective owners.
Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND
THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED
“AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY,
SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE
PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO
YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES, INCLUDING,
AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR
LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED
ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR
OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT
THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION
SHALL NOT TAKE ANY RESPONSIBILITY FOR ABNORMAL OPERATIONS, PRIVACY LEAKAGE OR
OTHER DAMAGES RESULTING FROM CYBER-ATTACKS, HACKER ATTACKS, VIRUS INSPECTION,
OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE
WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT
YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR
USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD
PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL
PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT
USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR
PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF
CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY
NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL CYCLE, OR IN SUPPORT OF HUMAN RIGHTS
ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE
LAW, THE LATTER PREVAILS.
This product and – if applicable – the supplied accessories too are marked
with “CE” and comply therefore with the applicable harmonized European
standards listed under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,
the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info
replacement of a battery with an incorrect type that can defeat a safeguard
(for example, in the case of some lithium battery types);
— disposal of a battery into fire or a hot oven, or mechanically crushing or
cutting of a battery, that can result in an explosion;
— leaving a battery in an extremely high temperature surrounding environment
that can result in an explosion or the leakage of flammable liquid or gas; and
— a battery subjected to extremely low air pressure that may result in an
explosion or the leakage of flammable liquid or gas
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recy- clethis.info
Appearance
CAUTION
IF THE BATTERY COMPARTMENT DOES NOT CLOSE SECURELY, STOP USING THE PRODUCT AND
KEEP IT AWAY FROM CHILDREN.
CAUTION
CHEMICAL BURNING DANGER DO NOT SWALLOW THE BATTERY KEEP NEW AND USED BATTERIES
AWAY FROM THE CHILDREN.
IF YOU THINK BATTERIES MIGHT HAVE BEEN SWALLOWED OR PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE MEDICAL ATTENTION.
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
REPLACEMENT OF A BATTERY WITH AN INCORRECT TYPE CAN DEFEAT A SAFEGUARD.
CAUTION
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS AND LOCAL
REGULATIONS.
Enrollment
Note: The enrollment progress will be completed in 3 to 10 seconds normally, and the maximum enrollment duration is 3 minutes.
- Log in to the APP Store, download, and install Hik-Pro.
- Power on the security control panel.
- Log in the APP and tap the icon “+” . Scan the QR code or input the control panel serial No. to add the control panel.
1 Enroll the Peripheral Locally
- In the APP, tap the “Enrollment Mode” button on the control panel page to make the control panel enter the enrollment status.
- Loosen the screw and remove the rear panel.
- Power on the peripheral, and it will be automatically enrolled to the control panel.
2 Enroll the Peripheral with QR and serial No.
- In the APP, tap the icon “+” and scan the QR code or serial No. on the peripheral.
- Loosen the screw and remove the rear panel.
- Power on the peripheral, and it will be automatically enrolled to the control panel.
Note: Hold the tamper button, and make the device power off and then power on for re-enrollment.
Installation
-
Check Signal Strength
Enter the signal checking mode by operating on the control panel. Trigger the detector.
Solid Green for 3 s – Strong Signal
Solid Orange for 3 s – Medium Signal
Solid Red for 3 s – Weak Signal
Red light flashes for 3S – Failure
-
Check the installation environment
-
Install the Detector
Note: The additional force shall be equal to three times the weight of the equipment but not less than 50N. The equipment and its associated mounting means shall remain secure during the installation. Atier the installation, the equipment, including any associated mounting plate, shall not be damaged. with Screws
a. Knock out the screw holes on the rear panel.
b. Secure the rear panel on the wall with four screws.with the Sponge Tape Paste the device on the wall with sponge tape.
Note : Installing with sponge tape is non EN compliant.
Bracket Installation
Ceiling Bracket Fiting (Non EN compliant)
Wall Bracket Fiting
Test
Detector zones and planes
The zones and plans of the detector are shown below.
The detector will enter the walk test mode (3 minutes) atier being enrolled.
Trigger the detector within the detection range.
If the LED indicator turns blue, the installation position is properly. If the
LED indicator is still off, adjust the position of the detector.
Formatting
Hold the tamper switch for 8 s and power the device on at the same time. The red LED flashes 3 times when the formating operation is completed.
Set up with App
Link the detector to the zone.
On the device list page, tap the AX PRO and then log in to the device (if
required) to enter the Area page.
Tap Device, and tap the zone.
You can view the device status including temperature, batiery status, signal
strength, etc.
Tap the buttuon in the upper right corner to enter the Settings page.
Function | Description |
---|---|
Zone Type | Select the zone type of the detector such as the instant zone, the |
24-hour zone, etc.
Stay Arm Bypass| Slide to green to bypass the zone from stay arming.
Forbid Bypass on Arming| Slide to green to forbid the zone with fault to be
bypassed automatically when arming.
Chime| Slide to green to enable the chime.
Silent Alarm| Slide to green to make the zone keep silent while alarm is
triggered.
Sounder Delay Time| Set the delay time. The sounder will be triggered
immediately or atier the set time.
---|---
Double Knock| Slide to green to make the zone alarm with double knock.
Cross Zone| If the alarm triggered in both of the linked zones within the set
time, two alarm messages will be reported.
Link Camera| Link with a camera for intruder verification.
LED| Turn On/Off the LED.
Swinger limit activations| Set the limit times of swinger activition.
Polling Rate| Set the interval of heartbeat.
Signal Strength Test| Enter the test mode, and view the LED indication.
Detection Zone Test| Enter the test mode, and start walk test.
Find Me| Tap Find Me to make peripherals find the zone.
Bypass| Slide to green to bypass the zone.
Operation Caution and Device Maintenance
- All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specification of the device for the detailed operation temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.
- The device for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time.
- Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situation.
Specification
Model | DS-PDP15P-EG2-WB/WE |
---|
Detection Performance
| Detection Method| Passive Infrared
Sensor Model| SFG321-711
Detection Range| 15m( 12 metre EN compliant)
Detection Angle| 85.9°
Detection Zones| 52
Detectable Speed| 0.3~2m/s
Sensitivity| Auto,High,Pet
Pet Immunity| 30Kg
White Light Filter| 6500lux
Digital Temperature Compensation| Support
Creep Zone Protection| Support
Feature
| Digital Processing| Support
Sealed Optics| Support
Tamper Protection| Front,Rear
Environment Temperature Indicator| Support
Signal Strength Indicator| Support
Interface| Power Switch| Power Up Enrolling
LED Indicator| Blue(Alarm)
Transmission
| Transmission Technology| Tri-X Wireless
Transmission Method| Two-Way RF Wireless
Transmission Frequency| 433MHz/868MHz
Transmission Security| AES-128 Encryption
Transmission Range(Free Space)| 1.2Km(433MHz)/1.6Km(868MHz)
Frequency Hopping| Support
Enrolling Method| Power up,Remote ID,QR Code
Electrical Characteristics
| Power Supply| Battery Powered
Battery Type| CR123A x 1 (included), 3V/1600mAh
Typical Voltage| 3V
Low Voltage Value| 2.45 V
Consumption| Max. current: 60mA
Quiescent current: 32uA (disarmed), 12uA (armed)
PS Type| Type C
Standard Battery Life| 5 Years
General
| Operation Temperature| -10 °C to 55 °C (14 °F to 131 °F)
Storage Temperature| -20 °C to 60 °C (-4 °F to 140 °F)
Operation Humidity| 10% to 90%
Dimension(WxHxD)| 65.5mm × 103mm × 48.5mm
Weight| 128g
Mounting Height| 1.8 to 2.4m
Mounting Method| Wall
Application Scenario| Indoor
Bracket| Optional Wall & Ceiling Accessory
Note: when the low voltage message appears there will be at least 30 days of use.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555
Qianmo Road, Binjiang District, Hangzhou 310052, China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>