MOXA MGate EIP3170 Series 1 and 2-Port EtherNet IP-to-DF1 Gateways Installation Guide

June 6, 2024
MOXA

MOXA LOGO

MOXA MGate EIP3170 Series 1 and 2-Port EtherNet IP-to-DF1 Gateways

Installation Guide

MOXA MGate EIP3170 Series 1 and 2-Port EtherNet IP-to-DF1
Gateways

Technical Support Contact Information
www.moxa.com/support

Overview

The MGate EIP3170 and EIP3270 are 1- and 2-port DF1-to-EtherNet/IP gateways that provide protocol conversions for users who need to connect Rockwell Automation PLCs to an EtherNet/IP network. The MGate EIP3000 Series products support up to 8 EtherNet/IP clients and 8 EtherNet/IP servers simultaneously. Each client can send up to 16 requests at one time.

Package Checklist

Before installing the MGate EIP3170 or EIP3270, verify that the package contains the following items:

  • MGate EIP3170 or EIP3270 DF1 to EtherNet/IP gateway
  • Quick installation guide (printed)
  • Warranty card

Optional Accessories:

  • DK-35A: DIN-rail mounting kit (35 mm)
  • Mini DB9F-to-TB Adaptor: DB9 female to terminal block adapter
  • DR-4524: 45W/2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC input
  • DR-75-24: 75W/3.2A DIN-rail 24 VDC power supply with universal 85 to 264 VAC input
  • DR-120-24: 120W/5A DIN-rail 24 VDC power supply with 88 to 132 VAC/176 to 264 VAC input by switch

Please notify your sales representative if any of the above items is missing or damaged.

Hardware Introduction

LED Indicators

FIG 1 LED Indicators

Reset Button

The reset button is used to load factory defaults. Use a pointed object such as a straightened paper clip to hold the reset button down for five seconds. Release the reset button when the Ready LED stops blinking.

Panel Layouts

The MGate EIP3170 has a male DB9 port and a terminal block for connecting to serial devices. The MGate EIP3270 has two DB9 connectors for connecting to serial devices.

FIG 2 Panel Layouts

Hardware Installation Procedure

STEP 1: Use a standard straight-through Ethernet cable to connect the unit to a network hub or switch.
STEP 2: Connect your device to the unit’s serial port.
STEP 3: Mount the unit on a DIN-rail.
STEP 4: Connect the power source to power input.

Wall or Cabinet Mounting
Mounting the MGate EIP3170/3270 on to a wall requires two screws. The heads of the screws should be 5 to 7 mm in diameter, the shafts should be 3 to 4 mm in diameter, and the length of the screws should be more than 10.5 mm.

NOTE: Wall mounting is certified for use in maritime applications.

FIG 4 Wall or Cabinet Mounting

Software Installation Information

You can download the MGate Manager, User’s Manual, and Device Search Utility (DSU) from Moxa’s website: www.moxa.com. Please refer to the User’s Manual for additional details on using the MGate Manager and DSU. Default IP address: 192.168.127.254

Pin Assignments
Ethernet Port (RJ45)

FIG 5 Pin Assignments

FIG 7 Pin Assignments

Environmental Specifications

FIG 8 Environmental Specifications

This device complies with Part 15 of the FCC rules.
Operation is subject to the following conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

ATEX and IECEx Information

EIP3170/ EIP3270 Serial

  1. Certificate number: DEMKO 18 ATEX 2168X

  2. IECEx number: IECEx UL 18.0149X

  3. Certification string: Ex nA IIC T4 Gc
    Ambient Range : 0°C ≤ Tamb ≤ 60°C (For suffix without -T)
    Ambient Range : -40°C ≤ Tamb ≤ 75°C (For suffix with -T)

  4. Standards covered:
    ATEX: EN 60079-0:2012+A11:2013, EN 60079-15:2010
    IECEx: IEC 60079-0 Ed.6; IEC 60079-15 Ed.4

  5. The conditions of safe usage:
    • The equipment shall only be used in an area of at least pollution degree 2, as defined in IEC/EN 60664-1.
    • The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP4 in accordance with IEC/EN 60079-0.
    • Conductors suitable for Rated Cable Temperature ≥ 100°C
    • Input conductor with 28-12 AWG (max. 3.3 mm2) to be used with the devices

EIP3170I/ EIP3270I Serial

  1. ATEX Certificate number: DEMKO 19 ATEX 2232X

  2. IECEx number: IECEx UL 19.0058X

  3. Certification string: Ex nA IIC T4 Gc
    Ambient Range : 0°C ≤ Tamb ≤ 60°C (For suffix without -T)
    Ambient Range : -40°C ≤ Tamb ≤ 75°C (For suffix with -T)

  4. Standards covered:
    ATEX: EN 60079-0:2012+A11:2013, EN 60079-15:2010
    IECEx: IEC 60079-0 Ed.6; IEC 60079-15 Ed.4

  5. The conditions of safe usage:
    • The equipment shall only be used in an area of at least pollution degree 2, as defined in IEC/EN 60664-1.
    • The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP 54 in accordance with IEC/EN 60079-0.
    • Conductors suitable for Rated Cable Temperature ≥ 100°C
    • Input conductor with 28-12 AWG (max. 3.3 mm2) to be used with the devices

Address of manufacturer: No. 1111, Heping Rd., Bade Dist.,
Taoyuan City 334004, Taiwan