laia 0000290987 Broadcaster Thermal Camera

Product Connection

Network Connection

Note:
Three main equipments are needed on the human body detection site: Temperature Measurement Blackbody: Provide standard temperature source, can provide real-time calibration for thermal & optical bi-spectrum camera on site. Thermal & Optical Bi-spectrum Camera: perform face recognition, human shape recognition, body temperature detection on the site personnel, and screen temperature abnormal personnel. Analysis Computer: control the thermal & optical bi-spectrum camera, display the image of the person, and perform temperature analysis, and alarm, take pictures, record video, report abnormal situation information when the temperature exceeds the limit.The thermal & optical bi-spectrum camera lens is compared with the black body radiation surface. The thermal & optical bi-spectrum camera can be connected to the analysis computer through the network cable, and the computer can automatically judge and analyze through the software.

TV Connection

The site is mainly composed of five devices:

  • Temperature Measurement Blackbody: Provide standard temperature source, can provide real-time calibration for thermal & optical bi-spectrum camera on site.

  • Thermal & Optical Bi-spectrum Camera: perform face recognition, human shape recognition, body temperature detection on site personnel, and screen personnel wit The video output can be Ethernet or HDMI output, and can be equipped with a computer and a TV for display.

  •  Two modes, PC-free temperature measurement and PC-based temperature measurement, can be used to minimize on-site installation.

  • Visible light and infrared dual simultaneous human body detection, visible light to identify human face and human body, infrared for accurate forehead positioning and temperature measurement.

  •  Blackbody provides standard temperature calibration at the scene, and will not cause temperature measurement deviations due to differences in environmental changes.
     Infrared thermal imaging supports 80*60, and visible light supports 1080P.
     Infrared thermal image and visible light picture are combined for temperature measurement, visible light picture temperature measurement, and thermal imaging picture temperature measurement can be switched and displayed.h abnormal temperature.

  •  Acousto-optic Alarm: When the temperature exceeds the limit of personnel, sound and light alarm.

  • TV: Display the detection screen, display the image of the personnel, and display the temperature.

  •  Mini Keyboard: Connect to the thermal & optical bi-spectrum camera to configure, control, modify and adjust.

Product Features

The concept is based on the current domestic and foreign markets’ latest requirements for infrared thermal imaging in terms of product performance, lightweight structure, cost and intelligence, and product stability. It adopts advanced dual-spectrum fusion technology design technology to establish an internationally leading level of dual-spectrum Linkage intelligent algorithm technology, the product represents the latest requirements in the market and the future consumer trends in the market.

  •  The video output can be Ethernet or HDMI output, and can be equipped with a computer and a TV for display.
  •  Two modes, PC-free temperature measurement and PC-based temperature measurement can be used to minimize on-site installation.
  • Blackbody provides standard temperature calibration at the scene, and will not cause temperature measurement deviations due to differences in environmental changes.
  •  Infrared thermal imaging supports 80*60, and visible light supports 1080P.
  •  Infrared thermal image and visible light picture are combined for temperature measurement, visible light picture temperature measurement, and thermal imaging picture temperature measurement can be switched and displayed.
  • Visible light and infrared can delimit different areas simultaneously.
  •  Image output mode: connect to computer or TV via Ethernet or HDMI.
  •  Support face recognition, human body recognition.
  •  Intelligent positioning personnel forehead temperature, accuracy error is less than 0.4℃.
  •  If the temperature exceeds the limit, local alarm can be given, and the data confirming the fever can be uploaded to the command center.
  •  The product has an Ethernet port and can be externally connected to a 4G/5G router.
  •  The secondary temperature calibration software can be used by the customer to perform secondary calibration and calibration according to different regional environments.
  •  For people with high body temperature, visible and infrared photos can be automatically taken and archived for easy traceability.
  •  The temperature measurement information can be reported to the government statistical center in real time, so as to quickly understand the information.

Packing List

No. Device Name Description Quantity Note

1

|

Thermal & Optical Bi-spectrum Camera

| HD lens 1080P, thermal imaging lens

80*60 resolution

|

1

|

Standard

2

|

Black Body Radiation Source

| Room temperature

+5℃~50℃, open cavity 50mm

|

1

|

Optional

3| Computer| 4G RAM above I3| 1| Optional
4| Analyzing Software|  | 1| Optional
5| Thermal Image Tripod|  | 1| Optional
6| Black Body Tripod|  | 1| Optional
7| Power Strip|  | 1| Optional

TV Connection:

No. Device Name Description Quantity Note

1

|

Thermal & Optical Bi-spectrum Camera

| HD lens 1080P, thermal imaging lens

80*60 resolution

|

1

|

Standard

2

|

Black Body Radiation Source

| Room temperature

+5℃~50℃, open cavity 50mm

|

1

|

Optional

3| TV|  | 1| Optional
4| Mini Keyboard|  | 1| Optional
5| Thermal Image Tripod|  | 1| Optional
6| Black Body Tripod|  | 1| Optional
7| Power Strip|  | 1| Optional
8| Audible Alarm|  | 1| Optional

Product Specification

Parameter Description

Infrared thermal image

| Resolution| 80×60
Working Band| 8~14um
Frame Rate| 25Hz
NETD| 70mK@25℃
Angle of View| 90 degrees horizontal
Temperature

Measurement Range

|

10℃~50℃

Temperature

Measurement Accuracy

| The temperature compensation algorithm can

reach ±0.4℃ for human body

Temperature Measurement

| The temperature measurement area can be set, and the temperature of the face can be automatically measured by human body

recognition and face recognition

Swatches

| Enhanced iron red, white hot, black hot, iron

red, rainbow, red hot, cold blue, etc.

Visible Light

| Resolution| 1080P
Angle of View| 120°
Frame Rate| 25Hz
Minimum Illumination| 0.5 Lux @ (F1.8,AGC ON)
BLC| Support
Digital Noise Reduction| 2D & 3D Digital Noise Reduction
Signal Noise Ratio| ≥55dB

General

|

Interface

| RJ45 Network Interface
HDMI Interface
RS485 Interface, can be connected to PTZ
Alarm Interface
USB Interface

General

|

No PC Operation

| Remote sensing keys can be used for PC-free operation, and mini keyboard operation

configuration can be used

---|---|---

Operating Temperature

| 0°C ~ +40°C (According to the requirement of accurate temperature measurement of human body, it is recommended to be the best under

the ambient temperature of 10°C ~ +30°C)

Storage Temperature| -10°C ~ +50°C
Waterproof and

Dustproof

|

IP54

Product Size| 129mm x 73mm x 61mm (L x W x H)
Net Weight| 295g

Picture Storage

| Support infrared, visible light, fusion photo

storage

Installation

| Use standard tripod installation or gimbal

lifting

Software

| Intelligent Application| Human body recognition, face recognition

Temperature Display

| Human body temperature measurement, face recognition temperature measurement, high temperature tracking in the measurement area, and fixed temperature measurement of

the center temperature

Alarm

| It supports temperature alarm exceeding the set threshold, which can be audible and capture photos at the same time and store

them

Software

|

Picture Frame Temperature Measurement

| Support picture frame temperature measurement, set temperature measurement separately according to different entry and exit

channels of personnel

---|---|---

Temperature Compensation

| According to the different environment, the staff set the temperature compensation by

themselves

Photograph| Open manual photo, alarm automatic photo

Internet Cloud Upload

| Need to be customized according to different

cloud needs

Language

| Chinese Simplified, Traditional, English,

Russian

Software Function

The software interface is as shown in the figure below. The display image can be displayed in three modes: single infrared, single visible light, and superimposed and integrated screen.

Item Category Name Description
System

| Palette| Switchable iron red, pseudo color, enhanced iron

red.

Image Switch| Switchable infrared, visible light, dual picture

fusion.

Area

Temperature Measurement

| Different areas can be set to measure temperature separately.
Temperature

Measurement Method

| Choice of full-screen maximum temperature, regional maximum temperature, automatic

temperature measurement by personnel.

System

|  | Secondary Temperature Adjustment| Provide temperature calibration function, can perform secondary temperature compensation correction on site according to different

environmental changes.

---|---|---|---
Output Record| The camera can capture and write videos and still pictures to the Micro SD card, and simultaneously send them back to the

designated background via Ethernet.

Video

Output

|  | Mode| Switchable HDMI or Ethernet output.
Alarm| Alarm Mode| GPIO

Interface Alarm

| Configurable GPIO alarm mode.
PC Sound

Alarm

| Support computer sound alarm.
Alarm Display| Alarm pop-up window, and take photo

automatically.

Firmware| Upgrade| Firmware| The camera support firmware upgrade.
Live Upgrade| The camera supports network port and Micro SD

card upgrade or downgrade firmware.

Prompt| The camera can recognize the latest firmware and prompt the user to upgrade to the latest

firmware.

Artificial Intelligence|  | Features| Human shape recognition, and line drawing

Face recognition, and mark the face profile

Intelligent calculation of forehead position, infrared aiming at

forehead, temperature sampling.

---|---|---|---
Communication|  | Communication Guarantee| The camera should be able to communicate with the PC through software under unknown IP conditions, or set the reset button to modify the IP address to ensure that field operations can communicate

with the PC.

Data Storage| Visible light images and videos| Take Photo| Can shoot infrared images, visible light images, three pictures on the

scene picture.

Video| Can be set to automatically record video, and manually record the

video files.

Picture| Picture Adjustment| Image Adjustment| You can adjust the brightness, white balance, contrast, saturation, sharpness and other parameters of

the image and video.

Image Flip| Image can be flipped horizontally

and vertically.

OSD|

| OSD Function| Support OSD function.
---|---|---|---
Time

Information Overlay

| OSD supports time information superimposed on images and

videos.

Temperature Information

Overlay

| OSD supports temperature and other information superimposed on

images and videos.

Report the epidemic situation| Reporting Interface| Reserved Reporting Interface| Confirm the epidemic personnel, report manually, personnel information, name, symptoms, photos, other information, work

situation.

Installation Precautions

  • The body temperature is different, and the forehead temperature is 1-2°C lower than the actual temperature. However, when the body has a fever, due to continuous fever, the difference between the forehead temperature and the actual temperature is not so large. Therefore, when you have a fever, the general default is 37.5°C.
  •  Environmental changes have a great influence on the temperature measurement accuracy of infrared thermal imaging. Although there are black body corrections, the large changes in the environment will also affect the black body. Therefore, try to choose a stable room temperature environment, and do not deploy thermal imaging thermometers and black bodies in places such as tuyere, air conditioner direct blow, fan direct blow, and heating equipment.
  •  The thermal & optical bi-spectrum camera and the black body should be arranged in the indoor environment as far as possible. The temperature of the environment should not change up and down to avoid direct sunlight on the device.
  •  As far as the background of the lens is concerned, try not to have other high-temperature equipment that is higher than the human body temperature, such as heating air conditioners, water heaters, high-power incandescent lamps and other high-temperature objects, to prevent false alarms.
  •  If there are inevitable high-temperature objects in the picture, you can draw a frame area on the software video, so that only the temperature in the area frame will be measured to avoid other interference.
  •  The background of thermal imaging is as simple and simple as possible. If the background is very complex, it is easy to produce false alarms, such as many lights.
  •  After the thermal image camera is turned on for 10 minutes, the internal temperature of the machine can reach thermal equilibrium. At this time, the temperature measurement is the most accurate, so it is recommended to start the measurement after 10 minutes of startup.
  •  The placement of the black body will directly affect the temperature measurement accuracy. When the device is shipped from the factory, it has been calibrated at a fixed distance. Therefore, the black body is best within half a meter of thermal imaging, and the measured person is preferably 1-2 meters away from the thermal & optical bi-spectrum camera.
  •  Individual non-patients with fever may have an over-temperature alarm. For example, after drinking alcohol, strenuous exercise, just drinking water, local facial inflammation, prolonged sun exposure, just coming out from a hot place, etc. At this time, the test person can be allowed to be quiet for a while or heat dissipation before the measurement screening.

Layout Instructions

Laying by the Wall Channel

Layout points:

  • The infrared thermal imager camera is diagonally opposed to the crowd, and only needs people to pass through the screen in order to complete the temperature measurement of the human body.
  • The black body serves as a reference for the standard temperature source and is placed on the side close to the passage of people and needs to be displayed in the image of the thermal & optical bi-spectrum camera.
  •  The thermal & optical bi-spectrum camera is 1.5 meters away from the temperature measurement line, and the channel width is 1 meter.

Security Door Mode

Layout points:

  •  The dual-spectral infrared thermal imaging camera has a downward angle of 15-30 degrees, with the head appearing in the picture 1.5 meters away from the thermal imager.
  • The black body is arranged next to the security door channel. The thermal imaging can see the black body, and the personnel will not block the black body when passing through the security door.

Lobby Entry Mode

Layout points:

  •  Do not cover the door of the thermal & optical bi-spectrum camera, because it will extend to the complex scene outside the door.
  •  The black body is on the side of the channel near the thermal imager to prevent it from being blocked.
  •  It is best for the personnel to penetrate in and not cover each other.
  •  The thermal & optical bi-spectrum camera reaches the left side of the channel, with a distance of 1-1.5 meters, and a channel width of 1 meter.

T-channel Layout

Layout points:

  •  The image of the thermal image camera is placed at the junction of the T-shaped channel, facing the pedestrian direction.
  • The distance from the thermal image camera to the pedestrian channel is about 1 meter.
  •  The black body is arranged on the side of the channel, on the same side as the thermal & optical bi-spectrum camera to prevent it from being blocked.

References