HIKVISION 2TE127 Black Body Calibrator User Manual

June 6, 2024
Hikvision

HIKVISION logo 2TE127 Black Body Calibrator
User Manual

© 2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.

About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images, and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (http://www.hikvision.com).
Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.
Trademarks Acknowledgement
HIKVISION logo and other Hikvision trademarks and logos are the properties of Hikvision in various jurisdictions.
Other trademarks and logos mentioned are the properties of their respective owners.
LEGAL DISCLAIMER
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE, AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITY FOR ABNORMAL OPERATIONS, PRIVACY LEAKAGE, OR OTHER DAMAGES RESULTING FROM CYBER-ATTACKS, HACKER ATTACKS, VIRUS INFECTIONS, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.  ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.

Symbol Convention

The symbols that may be found in this document are defined as follows.

Symbol Description
NOTE Provides additional information to emphasize or supplement

important points of the main text.
WARNING| Indicates a potentially hazardous situation, which if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
DANGER| Indicates a hazard with a high level of risk, which if not avoided, will result in death or serious injury.

Safety Instructions

WARNING
Input voltage should be from 100 VAC to 240 VAC, 50 Hz/60 Hz.
Check if the power or accessory is damaged before use.
Please use the supplied cable.
DO NOT charge the device or operate the device with wet hands.
DO NOT touch the radiation surface to avoid the scratch to influence the accuracy of temperature measurement.
The working status of the black body has been tested and debugged. DO NOT change the parameters on the temperature control panel, or it may lead to devise exception.
DO NOT aim the device at the sun, and protect it from wind during on-site calibration.

DANGER
Keep the camera away from liquid to avoid damage or danger.
DO NOT cover the ventilation holes while in use.
COMPLIANCE NOTICE:
The thermal series products might be subject to export controls in various countries or regions, including without limitation, the United States, the European Union, the United Kingdom, and/or other member countries of the Wassenaar Arrangement. Please consult your professional legal or compliance expert or local government authorities for any necessary export license requirements if you intend to transfer, export, or re-export the thermal series products between different countries.

Function

  • It is specially designed for calibrating body temperature detection thermal devices and thermal inspection devices in various sizes.
  • Excellent temperature uniformity, accuracy, and stability of calibration.
  • Adopts an intelligent temperature controller and has high-temperature control accuracy.
  • Good performance and favorable price compared with similar products.

Appearance and Panel Introduction

HIKVISION 2TE127 Black Body Calibrator - Panel
Introduction

Technical Data

Parameter Value
Temperature Range Adjustable: environment temperature+5 t (9 T), up to 50 t

(122 T)
Effective Radiating Area| 070 mm (2.76″)
Temperature Resolution| 0.1 t (0.18 cF)
Temperature Accuracy| ±0.1 t (0.18 IT)
Temperature Stability| ±0.1 t/h
Effective Emissivity| 0.97 ± 0.02
Power Consumption| 20 W
Environment Temperature| 0 t to 35 t (32 <F to 95 <F)
Weight| 1.85 Kg (4.08 lb)
Dimension| 120 mm x 176.6 mm x 119.6 mm (4.72″ x 6.95″ x 4.71″)
Power| 100 VAC to 240 VAC
Mounting| Mounting on a plane desk or a tripod with 1/4-20UNC Interface
or a ceiling mount bracket with 1/4-20UNC Interface

Mounting

  1. Check the power supply. The working voltage should be 100 VAC-240 VAC, 35 W.
  2. Check if the desk is horizontal.
  3. Mount the device on the desk or a tripod in front of the thermal camera firmly. Make sure that the front of the black body can show in the live view of the thermal camera completely, and outside the temperature measurement area.
  4. Switch on the device, and the power indicator is on. The factory default setting temperature is 40 °C.

Operation

  1. Connect the black body with a 10 A socket via the power cable.
  2. Switch on the device, and the power indicator is on. The factory default setting temperature is 40 °C.
  3. Wait for 30 minutes after switching on the device. You can calibrate the thermal camera when the temperature is stable at 40 °C.
  4. Switch off the black body and store it after use.

Maintenance

  1. The black body should be managed and maintained by a professional person, and maintenance and usage should be recorded.
  2. DO NOT use the device in an environment with oil or chemical air.
  3. To ensure temperature accuracy, place the device firmly in an environment with a stable temperature. The recommended using environment temperature is 10 °C to  25 °C (50 °F to 77 °F)
  4. Power off the device before mounting or removing it.
  5. Clean the surface of the device with a neutral detergent. Clean the dust on the black body with a soft brush.
  6. Store the device in the packing box after use to prevent dust. Make sure the environment temperature is suitable.
  7. DO NOT dismantle the device without authorization. Contact the professional specialist for repair.
  8. To ensure temperature accuracy, it is recommended to calibrate the black body once a year. Please send the device to a qualified calibration institute.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Hikvision User Manuals

Related Manuals