| Model / Lens| Wide-angle (H)| Corridor (LLPL02) (H)| Curtain (LLPL03) (H)
---|---|---|---|---
RK415PR
RK415PQ| 2m-3m (6’7’’- 8’10’’)
2m-3m (6’7’’- 8’10’’)| 2.5m (8’2.4”)
2.5m (8’2.4”)| 1.5m (Typical)
1.5m (Typical)
Mounting
1 | 2 | 3 |
---|---|---|
Wall mounting | Wall mounting | Wall mounting |
--- | --- | --- |
Swivel Mounting
- Remove the swivel entry knockout and cable entry knockouts located on the base of the detector.
- If required, remove wires entry knockouts on the swivel.
- Attach the swivel to the selected location on the wall or the ceiling.
- Attach the base to the swivel using the supplied plastic washer and attaching screw.
- Feed the cables into the detector base.
Terminal Wiring
Terminal Connection
- 12VDC: Power supply inputs
- ALARM: NC Dry Contact switch
- TAMPER: NC Dry Contact switch
- LED: 12VDC activated input.
LED is enabled if it is not connected or the 12VDC is applied.
The LED is disabled if GND is applied.
Jumper Settings
| | | Important
---|---|---|---
1 pulse| 2 pulses| 3 pulses| For corridor and curtain lens use only 1 pulse.
|
---|---
LED Enable| LED Disable
Schematic of EOL resistors
Walk test
Walk Test
Two minutes after applying power (warm-up period), walk test the detector over
the entire protected area to verify proper operation of the unit.
Replacing Lenses
Replacing Lenses
The detector’s lens is attached to the outside of the front plastic cover by
four clips.
To replace the lens:
- Push on each one of the four clips from inside of the cover.
- Lift the Lens from the outside of the cover.
- Select the desired lens and make sure that the long pin is pointed upwards.
- Insert two clips on one side of the lens into the matching holes in the cover and push them inside until click.
- Repeat step 4 with the two clips on other side of the lens.
- At the end, verify all four clips are holding the cover.
Ordering part numbers
Part / Model number| Description
RK415PR| DigiSense PIR 15m
RK415PQ| DigiSense Quad 15m
LLPL02| Corridor lens
LLPL03| Curtain lens
LEDs Display
LED | Description |
---|---|
RED | Indicates ALARM |
Technical Specifications
RK415PR / RK415PQ
Coverage| 15m x 15m (49’ x 49’)
Installation height| 2-3m (6’,6.7’’-9’,10’’)
Operating voltage| 9 to 16 VDC
Current consumption| 12mA at 12V, max23.5 mA at 16V
Alarm and Tamper contacts| 0.1A, 24V, NC
Optical filtering| White light protection, pigmented lens
Operating temperature| -20° to +55°C (-4°F to 131°F)
Storage temperature| -20° to + 60°C (-4°F to 140°F)
Dimensions| 106 x 60 x 47mm (4’’ x 2.3’’ x 1.8’’)
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates (“Seller”) warrant its
products to be free from defects in materials and workmanship under normal use
for 24 months from the date of production. Because Seller does not install or
connect the product and because the product may be used in conjunction with
products not manufactured by the Seller, Seller cannot guarantee the
performance of the security system which uses this product. Seller’s
obligation and liability under this warranty is expressly limited to repairing
and replacing, at Seller’s option, within a reasonable time after the date of
delivery, any product not meeting the speci cations. Seller makes no other
warranty, expressed or implied, and makes no warranty of merchantability or of
fitness for any particular purpose. In no case shall the seller be liable for
any consequential or incidental damages for breach of this or any other
warranty, expressed or implied, or upon any other basis of liability
whatsoever. The seller’s obligation under this warranty shall not include any
transportation charges or costs of installation or any liability for direct,
indirect, or consequential damages or delay. Seller does not represent that
its product may not be compromised or circumvented; that the product will
prevent any personal injury or property loss by burglary, robbery, re or
otherwise; or that the product will in all cases provide adequate warning or
protection. Buyer understands that a properly installed and maintained alarm
may only reduce the risk of burglary, robbery, or re without warning, but is
not insurance or a guarantee that such event will not occur or that there will
be no personal injury or property loss as a result thereof. Consequently, the
seller shall have no liability for any personal injury, property damage, or
loss based on a claim that the product fails to give a warning. However, if
the seller is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of cause
or origin, the seller’s maximum liability shall not exceed the purchase price
of the product, which shall be the complete and exclusive remedy against the
seller. No employee or representative of Seller is authorized to change this
warranty in any way or grant any other warranty.
WARNING: This product should be tested at least once a week.
UK Tel: +44-161-655-5500
E-mail: support-uk@riscogroup.com
50131-2-2 Grade 2 Environmental Class II