VGTL-DS-630 SKY 630R Greenhouse Top Light
INSTALLATION INSTRUCTIONS
VOLT® Grow Light
VGTL-DS-630 & VGTL-FS-630
Help Hotline:
1-813-978-3700 • Mon-Fri 8am-8pm • Sat-
Sun 10am – 6pm (EST)
Specifications and product details subject to change without notice.
© Copyright 2022, VOLT® Lighting, Lutz FL USA 33549 • All rights reserved.
customersupport@voltlighting.com •
813.978.3700
**** Important: Please Read Before Installation
This luminaire is intended for installation in accordance with local codes and
the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
- To prevent damage to the fixture, avoid touching or direct contact with the LED chips. Failure to follow this warning may results in product failure or void the warranty.
- Mounting and installation of the LED fixture should ONLY be performed by a qualified electrician or certified professional, in accordance with applicable local laws and regulations.
- The installer is responsible for correct and safe installation.
- Ensure local electrical wire can support voltage and current requirements of the LED fixture.
- Avoid coiled cords and keep main leads separated to prevent electromagnetic interference.
- Do not connect or disconnect the LED fixture under load.
- Mount to a structure that can support the weight of the LED fixture.
- Ensure external switching gear can support the inrush current of the LED fixture. Always use a double pole contactor that is suitable for switching a capacitive load. Never use household timer to switch the LED fixture.
- Ensure power cords and controller cables do not touch the LED rails after assembly.
Important Safety Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS Lighted lamp
is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
-
Do not connect or disconnect the power cable to the LED fixture while under load.
-
Do not open or disassemble the LED fixture, it contains no serviceable parts inside. Opening or modifying the LED fixture can be dangerous and will void the warranty.
-
This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45 – 30 MHz.
-
Do not use the LED fixture when either the LED fixture or its power cord are damaged. Replace the power cord only with original certified cords.
-
Modifications to the cords can lead to unwanted electromagnetic effects, which makes the product not comply with legal requirements.
-
Do not expose the LED fixture to:
a. ambient temperature outside the specified range;
b. dust and contamination;
c. direct sunlight during use or HID light that could heat up the ballast. -
Store the LED fixture in a dry and clean environment, with an ambient temperature of -4-180⁰F (-20-80⁰C).
-
Always disconnect the LED fixture from mains before performing any maintenance.
-
Always allow for a cool down period of at least 30 minutes before touching the LED rails. Touching the LED rails when the fixture is lit or immediately afterwards can result in severe burns!
-
Do not use the LED fixture near flammable, explosive or reactive substances. Do not use sulfur vaporizers.
-
The installation and use of the LED fixture is the responsibility of the end user. Incorrect use or installation can lead to failure and damage to the LED fixture. Damage to the LED fixture and electronic circuitry as a result of incorrect installation and use revokes the warranty.
-
Regularly check the LED fixture for dust or dirt buildup. Clean if necessary. Contamination may cause overheating and decreased performance. Clean the outside of the LED fixture using a dry or damp cloth.
-
Regularly check the cables of the LED fixture to ensure it is undamaged.
-
These photobiological safety markings are based on testing of the light output characteristic of a single horticultural luminaire. Increased exposure risk to facility personnel may be present depending upon the number of horticultural luminaires and their placement and/or positioning within the plant growth facility.
It is the responsibility of the plant growth facility to address these risks at the facility level and to ensure that people entering the plant growth areas while the lights are on, are aware of these risks and that appropriate safeguards are in place.
**** Important UL Warnings
1. Required minimum 15cm distance between adjacent lighting equipment and
between the lighting equipment and combustible material such as walls,
ceilings, movable partitions, and the like; and between lighting equipment and
other heat generating equipment.
2. SUITABLE FOR OPERATION IN AMBIENT NOT EXCEEDING 40 ⁰C.
3. A mechanical ventilation or cooling system is required to maintain the
temperature within the growing space below 40⁰C when the horticultural
luminaire is in operation.
4. SUITABLE FOR DAMP LOCATIONS.
a. Are not concealed or extended through a wall, floor, ceiling, or other
parts of the building structure;
b. Are not located above a suspended ceiling or dropped ceiling;
c. Are not permanently affixed to the building structure;
d. Are routed so that they are not subject to strain and are protected from
physical damage;
e. Are visible over their entire length; and
f. Are used within their rated capacity as determined for the maximum
temperature of the installed environment specified in the instructions.
5. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF
THE PRODUCT AND THE HAZARDS INVOLVED.
6. Make sure below ELECTRICAL RATINGS are well followed:
Input Ratings| Photobiological
rating
---|---
Voltage
(VAC)| Frequency
(Hz)| Max.
Current (A)| Wattage
(W)
120-277| 50/60| 6.| 630| Risk group 2
347-480| 50/60| 2| 630| Risk group 2
7. Warning:
RISK GROUP 2
CAUTION
UV emitted from this product. Eye or skin irritation may result from exposure.
Use appropriate shielding.
Product tested against IEC62471
www.voltlighting.com
Package Contents
A. (1) Grow Light
B. (1) Driver Assembly
C. (4) Lock Screws
D. (2) Self-tapping Screws
E. (1) AC Power Cable
F. (4) Cable Ties
G. (4) Driver Hangers — 2 pcs of each kind
3919-12
Unistrut
Wire Hanger
2Pcs| 3919-13
Combo Mount
Wire Hanger
2Pcs
H. (8) Fixture Hangers — 2 pcs of each kind
3919-11
Unistrut
Wire Hanger 2Pcs| 3919-14
Combo Mount
Wire Hanger 2Pcs| 3919-15
Prependicular
Mount Wire
Hanger 2Pcs| 3919-16
Parallel Mount
Bracket 2Pcs
I. (2) Bracket 3919-19
Surface Mount Kit 2Pcs
Product Dimensions
Install Driver Assembly
There are 3 installation options available, please refer to the following installation instructions.
Option 1 – Unistrut Wire Hanger (3919-12)
Attach two unistrut wire hangers (3919-12) onto the support bar. Lift the
driver assembly up to the support bar and attach the unistrut hooks (3919-12)
to the holes of the driver assembly as shown. The driver assembly will be
secure with two unistrut wire hangers (3919-12).
Make sure the driver assembly is secured safely before releasing your
hands.
Option 2 – Combo Mount Wire Hanger (3919-13)
Attach two combo mount wire hangers (3919-13) onto the support bar.
Lift the driver assembly up to the support bar and attach the combo mount wire
hangers (3919-13) to the holes of the driver assembly as shown. The driver
assembly will be secure with two combo mount wire hangers (3919-13).
Make sure the driver assembly is secured safely before releasing your hands.
Option 3 – Surface Mount
Kit (3919-19)
A. Attach the surface mount kit (3919-19) onto the driver assembly and secure
with the lock screws.
Hand tighten with a screwdriver. B. Place the above assembly onto the support bar and
secure with selftapping screws.
Install Grow Light
There are 5 installation options available, please refer to the following
installation instructions.
Option 1 – Unistrut Wire Hanger (3919-11)
Install the grow light next to the driver assembly using any of the above 3
options.
Attach two unistrut wire hangers (3919-11) onto the support bar. Lift the grow
light up toward the support bar. Attach the hooks at the ends of unistrut wire
hangers (3919-11) to the holes on the end of the grow light as shown. The
holes are marked with “1” in the below sketch diagram. The grow light will be
secure with two unistrut wire hangers (3919-11). Option 2 – Combo Mount Wire Hanger (3919-14)
A. Insert one end of the combo mount wire hanger (3919-14) into the gap on the
grow light, which is marked with “2” on the below sketch diagram.
B. Rotate the combo mount
wire hangers (3919-14) until the grow light sets on them properly.
C. To hang the grow light
on the bottom of the driver assembly. Hold the hook ends of combo mount wire
hangers (3919-14) to lift the grow light up to the driver. Place the hooks
into the holes on the driver assembly as shown. Make sure the grow light is
secured
before releasing your hands. Option 3 – Perpendicular Mount Wire Hanger (3919-15)
Attach two perpendicular mount wire hangers (3919-15) onto the support bar.
Lift the grow light up to the support bar. Put the hooks at the ends of
perpendicular mount wire hangers (3919-15) into the gaps on the grow light as
shown. These gaps are marked with “3” in the below sketch diagram. The grow
light will be secure with two perpendicular mount wire hangers (3919-15) .
Make sure the grow light is secured safely before releasing your hands.
Option 4 – Unistrut Wire
Hanger (3919-11)
Place two unistrut wire hangers (3919-11) on two sides of the driver assembly.
Attach two unistrut wire hangers (3919-11) onto the support bar. Lift the grow
light up to the support bar. Put the hooks at the ends of unistrut wire
hangers (3919-11) into the holes on the ends of the grow light as shown. These
holes are marked with “4” in below diagram. The grow light will be secure with
two unistrut wire hangers (3919-11).
Make sure the grow light is secured safely before releasing your hands. Option 5 – Parallel
Mount Bracket (3919-16)
A. Find the support plates on the back of the grow light. Pass the parallel
mount brackets (3919-16) through the gap between the grow light and the
support plate as shown. The grow light will be supported by two parallel mount
brackets (3919-16).
B. Place the parallel mount brackets (3919-16) onto the support bar. Make sure
the grow light is secured safely before releasing your hands.
Connect Wires
Tie Slack Cable to Support Plate
Trace the slack cable
along the top of the grow light. Tie the cable to the support plate by using
the cable tie.
Connect Dimming Wire from Controller to Driver Assembly
Using a UL listed wire connector, connect one dimming wire (purple wire “DIM
+”) from the driver assembly to “DIM+” wire from controller (sold separately).
Then connect the other dimming wire (pink wire “DIM-”) from the driver
assembly to the “DIM-” wire from controller (sold separately).
Note: Cap unused lead with UL listed wire connector. Connect Sensor or Fans to Driver Assembly
(If Applicable)
Using a UL listed wire connector, connect the yellow wire “AUX +” of the
driver assembly to the black wire from sensor or fan. Connect the pink wire
“AUX-” of the driver assembly to the white wire from the sensor or fan.
Note: Cap unused lead with UL listed wire connector. Connect DC Cables
Connect the cable from
the grow light to the DC Out cable on the driver assembly.
Connect AC Power Cable Connect the AC power cable to the AC In cable on the driver
assembly. Insert the plug on the AC power cable into the wall outlet.
Note: AC Power Cable varies according to different volt range. Refer to
the following chart for detailed information.
Input Voltage | Plug Style | Plug Model Number | Wire Spec |
---|---|---|---|
120V~277V | 120V Plug | NEMA 5-15P | 600V,105º Celsius degree, 3*18AWG, UL_SOOW |
240V Plug | NEMA 6-15P | ||
277V Plug | NEMA L7-15P | ||
347V~480V | 347V Plug | NEMA L24-20P | |
480V (Direct wire) | / |
Troubleshooting
Descriptions | Causes/Solutions |
---|---|
No light output. | 1. Power cord isn’t connected properly or connections are |
loose.
a. Check the power cable connections.
Light burn or light stress (Green plants leaves or tips becoming yellow
unnaturally).| 1. LED lights are too close to green plants.
a. Move your LED lights further away from green plants right away.
Specifications and product details subject to change without
notice.
© Copyright 2022, VOLT® Lighting, Lutz FL USA 33549 • All rights reserved.
customersupport@voltlighting.com •
813.978.3700
IS-VGL3-XS-630-ver2.pdf