aloxy Pulse v01 Wireless IOT Sensor Instruction Manual
- June 5, 2024
- aloxy
Table of Contents
- aloxy Pulse v01 Wireless IOT Sensor
- Legal information
- Introduction
- Radio compliance
- **European marking label
- Safety instructions
- Installation and commissioning
- Dimensions
- Installing/mounting
- Usage of the Aloxy Pulse
- Inspections and maintenance
- Disposal
- Technical data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
aloxy Pulse v01 Wireless IOT Sensor
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your
personal safety, as well as to prevent damage to property. The notices
referring to your personal safety are highlighted in the manual by a safety
alert symbol, notices referring only to property damage have no safety alert
symbol. These notices shown below are graded according to the degree of
danger.
Signal Words
The following signal words, as defined by the ANSI Z535.6 standard, are used
in this document.
DANGER: indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury. It may also be used to alert against
unsafe practices.
NOTICE is used to address practices not related to personal injury.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified for the specific task in accordance with the relevant
documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are
capable of identifying risks and avoiding potential hazards when working with
these products/systems. Proper use of ALOXY products
Introduction
Purpose of this documentation
This instruction manual includes specifications, installation, basic setup and
configuration, and maintenance and troubleshooting information for the ALOXY
Pulse. Do not install, operate, or maintain a ALOXY Pulse without being fully
trained and qualified in valve, , and accessory installation, operation, and
maintenance. To avoid personal injury or property damage, it is important to
carefully read, understand, and follow all of the contents of this manual,
including all safety cautions and warnings. If you have any questions about
these instructions, contact your ALOXY sales office or Local Business Partner
before proceeding. See also http://www.aloxy.io
Purpose
The Aloxy Pulse is a multi-purpose industrial Internet-of-Things device and
platform that enables numerous different applications. Typically, it will be
attached to (industrial) assets such as valves, motors, pumps or mobile
vehicles to monitor their behavior and state based on its inertial sensors.
Depending on the use-case, the Aloxy Pulse can be programmed or configured to
capture signals from one of its embedded sensors, perform initial pre-
processing of the measured data on its microcontroller and wirelessly transmit
the resulting data over one of the supported communication networks.
For instance, by attaching the Aloxy Pulse to the hand wheel or lever of a manual valve, it can monitor the position (open or closed) of the valve in real-time. By attaching the Aloxy Pulse to rotating equipment such as a motor or ventilation unit, it can monitor vibrations or ambient temperature and in real-time send an alert when a certain threshold is exceeded. The ALOXY Pulse is a wireless IOT sensor used for manual valve position monitoring in the following Industries:
- Chemicals
- Oil and gas
- Energy production
- Food and beverages
- Pulp and paper
- Water/waste water
- Pharmaceutical industry
- Offshore plants
Checking the consignment
- Check the packaging and the delivered items for visible damage.
- Report any claims for damages immediately to the shipping company.
- Retain damaged parts for clarification.
- Check the scope of delivery by comparing your order to the shipping documents for correctness and completeness.
Radio compliance
USA radio compliance (FCC compliance)
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Canadian radio compliance
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device mustaccept any interference, including interference that may cause undesired operation of the device. English version This device complies with Industry Canada’s RSSs applicable to licence-exempt radio equipment. Operation is permitted under the following two conditions: (1) the apparatus shall not cause interference, and (2) the user of the apparatus shall accept any radio interference received, even if the interference may cause undesired operation.
Marking label
The identification label of the Aloxy Pulse is attached to the bottom of the
device:
**European marking label
**
- Manufacturer
- Manufacturing QR code
- Warning
- Protection class
- ATEX/IECEx marking for hazardous area
- Serial number (Order code)
- Product name, type and year of manufacturing
- ATEX / IECEx marking for hazardous area
- Permitted ambient temperature for the hazardous area of the corresponding temperature class
- Approvals
- Conformity with country-specific directives
- Waste instructions
- Consult operating instructions
USA & Canadian marking label
- Manufacturer
- Manufacturing QR code
- Conformity with country-specific cerifications (FCC, cFMus)
- FM / CSA marking for hazardous area
- Ingress Protection class
- Permitted ambient temperature for the hazardous area of the corresponding temperature class
- Product name, type and model
- Serial number (Order code)
- Waste instructions
- Consult operating instructions
- FCC ID n°
- Warning
- cFMus approvals cerification N°
- ISED ID N°
- Year of production
- Place of manufacture
- . FCC statement (there is no room for this on the label) see instruction manual
ALOXY provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state- of-the-art industrial security concept. ALOXY products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. ALOXY products and solutions undergo continuous development to make them more secure. ALOXY strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats.
Transportation and storage
To guarantee sufficient protection during transport and storage, observe the
following:
Notes on warranty
The contents of this manual shall not become part of or modify any prior or
existing agreement, commitment or legal relationship. The sales contract
contains all obligations on the part of ALOXY as well as the complete and
solely applicable warranty conditions. Any statements regarding device
versions described in the manual do not create new warranties or modify the
existing warranty. The content reflects the technical status at the time of
publishing. ALOXY reserves the right to make technical changes in the course
of further development.
Safety instructions
Precondition for use
This device left the factory in good working condition. In order to maintain this status and to ensure safe operation of the device, observe these instructions and all the specifications relevant to safety. Observe the information and symbols on the device. Do not remove any information or symbols from the device. Always keep the information and symbols in a completely legible state.
Warning symbols on the device
Laws and directives
Observe the test certification, provisions and laws applicable in your country
during connection, assembly and operation. These include, for example:
- National Electrical Code (NEC – NFPA 70) (USA)
- Canadian Electrical Code (CEC) (Canada)
Further provisions for hazardous area applications are for example:
- EN 60079-0
- EN IEC 60079-0
- EN 60079-11
Conformity with European directives
The CE marking on the device shows conformity with the regulations of the
following European guidelines:
Electromagnetic compatibility EMC
2014/30/EU
| Directive of the European Parliament and of the Council on the harmonization of the laws of the Member States relating to
electromagnetic compatibility.
---|---
Atmosphère explosible ATEX
2014/34/EU
| Directive of the European Parliament and of the Council on the harmonization of the laws of the Member States relating to equipment and protective systems intended for use in potentially
explosive atmospheres.
Use in areas subject to explosion hazard
Qualified personnel for hazardous area applications Persons who install, connect, commission, operate, and service the device in a hazardous area must have the following specific qualifications:
- They are authorized, trained or instructed in operating and maintaining devices and systems according to the safety regulations for electrical circuits, high pressures, aggressive, and hazardous media.
- They are authorized, trained, or instructed in carrying out work on electrical circuits for hazardous systems.
- They are trained or instructed in maintenance and use of appropriate safety equipment according to the pertinent safety regulations.
Installation and commissioning
- Aloxy logo, Ex marking & NFC area: The Aloxy logo indicates the area of the Aloxy Pulse device that can be scanned by an NFC reader or NFC-enabled smartphone or tablet.
- Left LED: Multi-color LED light on the left-side of the device allowing to give a light signal to the user
- Left button: Left push button for configuration and operation actions
- Top shell of the enclosure of the Aloxy Pulse device
- Bottom shell of the enclosure of the Aloxy Pulse device
- Mounting bracket: Detachable bracket for easy mounting of the device to any surface
- Right LED: Multi-color LED light on the right-side of the device allowing to give a light signal to the user
- Right button: Right push button for configuration and operation actions. Contrary to the left button, the right button can be recognized by the wave pattern on the button.
- Release slot: Slot to unlock the Aloxy Pulse sensor from the mounting bracket.
WARNING
Please observe the corresponding safety instructions when working on manual
valves in use. Impermissible accessories and spare parts
Risk of explosion in areas subject to explosion hazard.
- Only use original accessories or original spare parts.
- Observe all relevant installation and safety instructions described in the instructions for the device or enclosed with the accessory or spare part.Mechanical impact energy
- In order to ensure the degree of protection of the housing (IP69), protect the housing from mechanical impact energy:
Dimensions
The Aloxy Pulse has the following dimensions: length 88.5mm x with 41.2mm x height 50.3mm, including the mounting bracket.
The individual mounting bracket has the following dimensions: length 85.9mm x with 39.1mm x height 12.8mm:
The screw holes in the mounting bracket have a diameter of 5.4mm and are positioned at a distance of 60mm:
Installing/mounting
WARNING
- Always wear protective clothing, gloves, and eyewear when performing any installation procedures to avoid personal injury or property damage.
- Check with your process or safety engineer for any additional measures that must be taken to protect against process media.
Loss of explosion protection
The Aloxy Pulse can only be used within a process temperature range of -40°C ≤
Ta ≤ +70°C when mounted on pipes or machines.
Loss of type of protection
Damage to device if the enclosure is open or not properly closed. The type of
protection specified on the nameplate or in technical data is no longer
guaranteed.
Incorrect mounting
The device can be damaged, destroyed, or its functionality impaired through
improper mounting.
Usage of the Aloxy Pulse
Mounting the Aloxy Pulse to an industrial asset
The Aloxy Pulse is only intended for fixed installations and NOT for portable
use. Always follow EN-IEC 60079-14, local regulations and local codes of
practice when using the Aloxy Pulse.
The Aloxy Pulse can be attached to any (industrial) asset using a variety of
attachment methods such as bolts, straps, magnets or glue. Following procedure
must be followed precisely.
Step 1: Remove the Aloxy pulse device from the mounting bracket. To remove the
Aloxy Pulse device from its mounting bracket, put a screwdriver or similar
tool in the release slot to unlock the Aloxy Pulse device from the mounting
bracket. Gently pull the device to the left side while holding the mounting
bracket in position and keeping the screwdriver inserted in the release slot.
Step 2: Attach the mounting bracket to the asset
Depending on the type of asset and surface, the mounting bracket offers
several options to attach, either directly using plastic / metal straps, bolts
/ screws (M5), magnets or glue, either by using an external metal bracket in
between the mounting bracket and the asset surface.
CAUTION: Before sliding the Aloxy Pulse device in its mounting bracket after installation, ensure the mounting bracket is firmly attached on the asset and does not move when putting force in any direction.
NOTICE:When the Aloxy Pulse should measure a certain motion, for instance the motion of the hand wheel of a manual valve to monitor the valve’s position, make sure that the Aloxy Pulse device is attached to the moving part and follows the same motion as the part it is monitoring. No other motions are allowed after installing the sensor! The following installation examples ensure a correct fixation of the mounting bracket to the surface of an asset. Depending on the formfactor of the asset and the use-case, certain attachment methods are more suited than others. For instance, to monitor vibration, the Aloxy Pulse should be firmly attached to the surface of the asset to follow the same vibration pattern, hence, options using glue or clips are not well suited.
Installation using double straps (metal or plastic) on a tube- or bar-shape surface:
This method ensures good, non-intrusive fixation of the Aloxy Pulse to an
asset suitable for instance for movement detection and vibration monitoring.
Typical applications are manual valve position monitoring by attachment to a
valve lever or a spoke of the valve wheel, vibration monitoring of a tube,
asset tracking, etc.
For cable tie use for instance:
ALOXY article ID: 43361.186.047
CABLE TIE PLASTIC POLYAMIDE (NYLON) 6.6 UV-RESISTANT 186X4.7
Installation using a generic external metal U-bracket on a U-clamp that can beattached around a tube-shape surface:
This method ensures good, non-intrusive fixation of the Aloxy Pulse to an asset suitable for instance for movement detection and vibration monitoring. Typical applications are manual valve position monitoring by attachment to a valve lever or a spoke or outer ring of the valve wheel, vibration monitoring of a tube, etc.
Installation using M5 bolts or screws on a flat surface:
Use M5 bolts or screws with a maximum head height of 4 mm, such as hexagon
socket head (DIN 7984) cap screws with low head.
This method ensures excellent, but intrusive fixation of the Aloxy Pulse to an
asset suitable for instance for movement detection and vibration monitoring.
Typical applications are manual valve position monitoring by attachment to a
flat valve lever or a flat spoke of the valve wheel, vibration monitoring of
the surface of rotating equipment, asset tracking of mobile vehicles,
attachment to a wooden surface, etc.
It is best to use the following bolts and nuts:
- LOW-BULB HEAD of max SCREW WITH HEXAGON SOCKET ISO 7380-1 STAINLESS STEEL A2 M5X10
- SELF-LOCKING HEXAGON NUT WITH PLASTIC WASHER DIN 985 STAINLESS STEEL (STAINLESS STEEL) A2 M5
Installation on a flat metallic surface using two magnets:
CAUTION: The magnet material has been specifically chosen to provide a long-term stable magnetic field. However, as with any magnet, care must be taken when handling the magnet assembly.
This method ensures good, non-intrusive, rather temporary fixation of the Aloxy Pulse to a flat metallic surface suitable for instance for movement detection and vibration monitoring. Typical applications are temporary vibration monitoring of a rotating equipment, temporary asset tracking, temperature monitoring around a motor, etc.
Installation on a surface using double sided foam sticker:
This method ensures fair, non-intrusive fixation of the Aloxy Pulse to a flat asset surface suitable for instance for movement detection and temperature monitoring. Typical applications are asset tracking, temperature monitoring around a motor, etc.
Installation using an external metal bracket on the spindle of a multi-turn valve:
This method ensures excellent non-intrusive attachment of the Aloxy Pulse to the handwheel of a multi-turn valve. A typical application is manual valve position monitoring of small multi-turn valves.
Installation using an external metal bracket on the spindle of a quarter-turn valve:
This method ensures excellent non-intrusive attachment of the Aloxy Pulse to
the lever of a quarter-turn valve. A typical application is manual valve
position monitoring of small quarter-turn valves.
Step 3: Slide the Aloxy Pulse device in its mounting bracket Position the
Aloxy Pulse device on top of the mounting bracket slightly to the left-side so
the hooks below the Aloxy Pulse device align within the mounting bracket (a).
Slide the Aloxy Pulse device to the right-side until it locks in position (b).
Check that the edges of the Aloxy Pulse device perfectly align with the edges
of the mounting bracket.
To remove the Aloxy Pulse device again from its mounting bracket after installation, put a screwdriver or similar tool in the release slot to unlock the Aloxy Pulse device from the mounting bracket. Gently pull the device to the left side while keeping the screwdriver in the release slot.
Inspections and maintenance
Basic safety instructions
DANGER
The ALOXY Pulse contains one primary lithium metal battery pack. Under normal
conditions of use, the battery materials are self-contained and are not
reactive as long as the batteries and power module integrity are maintained.
Care should be taken to prevent mechanical, electrical, or thermal damage. DO
NOT recharge, short-circuit, disassemble, heat, or expose the battery pack to
water. The battery contain flammable materials and performing any of the above
actions could cause them to become damaged, ignite, or explode, resulting in
personal injury or property damage. Observe all warnings included with the
battery pack before installing, operating, storing, or shipping the ALOXY
Pulse.
The devise contains high power lithium batteries designed especially for this
sensor and for the conditions as foreseen on the marking label. The use of
non-original batteries can cause serious injuries!
Personal injury and property damage can result from fire or explosion if the
battery pack is subjected to heat above 100°C (212°F). Battery packs should be
stored in a cool, dry and ventilated area; for maximum life, storage should
not exceed 30°C (86°F).
WARNING: Repair must be carried out by ALOXY authorized personnel only.
- Only battery replacement is allowedImpermissible accessories and spare parts
- Risk of explosion in areas subject to explosion hazard. Only use original accessories or original spare parts.
- Observe all relevant installation and safety instructions described in the instructions for the device or enclosed with the accessory or spare part.Loss of explosion protection
- Only original parts may be used to repair the sensor. Using non-original parts may cause injury or damage. Loss of explosion protection when:
Cleaning the enclosure
- Clean the outside of the enclosure with the inscriptions and the display window using a cloth moistened with water or a mild detergent.
- Do not use any aggressive cleansing agents or solvents, e.g. acetone. Plastic parts or the painted surface could be damaged. The inscriptions could become unreadable.
Battery replacement
To do so, the Aloxy Pulse device must be opened to access the battery
compartment. Remove the Aloxy Pulse device from its mounting bracket as
described in section 6.1 (step 3) and bring it to a workshop area.
An empty battery in the Aloxy Pulse can be replaced by a fully charged one. USE ONLY THE FOLLOWING BATTERIES ON THE ALOXY PULSE v01:
WARNING: Do not open the Aloxy Pulse in the field or within an hazardous (classified) area to replace the battery. The device can only be opened in a workshop equipped to handle electronic components. To open the Aloxy Pulse, put the device upside-down on a workbench and remove the 4 screws counter- clockwise from the screw holes using a Torx (6-point star-shaped) T10 screwdriver.
CAUTION: Risk of damaging the electronics
When opening the Aloxy Pulse, avoid touching the electronic circuits and the
green PCB (Printed Circuit Board) to avoid damage. Always ensure you are
discharged of static electricity by wearing for instance an antistatic wrist
strap band.
Lift the battery from its support in the top shell.
Unplug the battery connector from the PCB (Printed Circuit Board) connector, without removing the PCB from the top shell.
Remove the battery and replace it by a new fully charged battery. Connect the battery connector from the new battery to the PCB connector.
NOTICE:Condensation in the device Damage to device through formation of condensation if the temperature difference between transportation or storage and the mounting location exceeds 20 °C (36 °F). Before taking the device into operation let the device adapt for several hours in the new environment.Make sure that the wire running from the battery to the PCB is positioned on top of the battery, i.e., on the opposite side of the PCB, to ensure correct operation of the Aloxy Pulse device.Position the new battery on the support in the top shell and close the Aloxy Pulse again by repositioning the bottom shell on top. Close the device by the 4 original screws, using a calibrated torque screwdriver (with Torx T10 head) according to the table
To insure ingress protection IP69
Steps | Force |
---|---|
Insert the 4 screws | |
Hand-tighten the 4 screws clockwise at | 0 Nm |
Tighten the 4 screws in a clockwise direction at | 0,2 Nm (0.15 ft lb) |
Tighten the 4 screws in a clockwise direction at | 0,45 Nm (0.33 ft lb) |
Tighten the 4 screws again in a clockwise direction at | 0,45 Nm (0.33 ft lb) |
NOTICE Device damage
The maximum torque of the gasket must not be exceeded. Refer to the section
“Technical specifications for the torque value. The Aloxy Pulse is ready for
operational use and can be positioned in its mounting bracket as explained in
the previous chapter (step 3).
Disposal
Devices described in this manual should be recycled. They may not be disposed of in the municipal waste disposal services according to the Directive 2012/19/EC on waste electronic and electrical equipment (WEEE). Devices can be returned to the supplier within the EC, or to a locally approved disposal service for eco-friendly recycling. Observe the specific regulations valid in your country.
Technical support
If this documentation does not provide complete answers to any technical
questions you may have, contact Technical Support by addressing your questions
to: Carl.stevens@aloxy.io
Technical data
Battery powerd wireless IoT sensor, Type ALOXY Pulse vXX
Certifications| | | | | Reference
CE conformety| The applicable directives and applied standards with their
revision levels can be found in the EU declaration of conformity on the
Internet.
This product complies with the following directives: ATEX Directive (2014/34/EU)
Electro Magnetic Compatibility (EMC) (2014/30/EU)
Radio Equipment Directive (RED) (2014/53/EU) Reduction of Hazardous Substances (RoHS) (2011/65/EU)
| ALOXY_D_400_Declaratio n of Conformity ALOXY Pulse v01.docx
Electrical Classification| FM (Canada and USA) Intrinsically Safe resp. Non-
incendive
ATEX— Intrinsically Safe
IECEx— Intrinsically Safe
| NA
Ex| Intrinsic safety “i”, “IS” for GAS zone 1|
Temp range -40°C ≤ Ta ≤ +70°C (-40 to 158°F)
|
ATEX / IECEx| II 2G Ex ib IIC T4 Gb| DEKRA 19ATEX0032
Ex ib IIC T4 Gb| IECEx DEK 19.0016
cFMus| Non-incendive
Class I, Division 2, T4 groups ABCD
| US cert # FM20US0065X
Canada Cert # FM20CA0029X
Class I, Zone 1, AEx ib IIC T4 Gb
Class I, Zone 1, Ex ib IIC T4 Gb
QMS| | 223642700-19ATEXQ0058 Iss.0-QAR19.0009-00-
PQAN
FCC| USA| FCCID: XXXXX-XXXXXX| Certification ongoing
ISED| Canada| IC: XXXXX-XXXXXX CAN ICES-X (B) / XXX-X (B)| Certification
ongoing
LoRaWAN| EU| | Labo De Nayer
PCC-RAD-4918_ed2 PCC-RAD-5034_ed2
---|---|---|---
USA| | Certification ongoing
Canada| | Certification ongoing
DASH7| EU| | Self-certification based on D7A v1.2 towards reference stack
implementation
USA| | Certification ongoing
Canada| | Certification ongoing
Compliant| | | | | Reference
WEEE| 2011/65/EU
RoHAS| 2012/19/EU
Enclosure| | | | | Reference
Mounting
position
| Horizontal or vertical| NA
Demensions| L x H x W| 88,5 x 50,3 x 41,2 mm| NA
Weight| With PCB and power supply| approx. 150gr (5.3oz)| NA
Battery| approx. 50gr (1.8oz)| NA
Lithium content 2,2 gr (0.078oz)| NA
Materials| Top shell| Softpart
yellow
| TPE yellow (conductivity 285Mohm)| Kraiburg HTC8797/137
| Softpart
black
| Nylabond TE ESD| RTP C146255B1Black
| Hard part| Nylon PA6 natural| SOLVAY Technyl C206F
Bottom shell| Nylon 6 ESD protection black| RTP0299AX123289BLACK
Mounting plate
PA6 general information| Thermoplastics used are non-reinforced polyamide, PA
We use the modern, semi-crystalline insulation material, polyamide, which is now an essential component in electrical engineering and electronics. It has long occupied a leading position and is authorized for use by the relevant approval authorities such as the CSA, KEMA, PTB, SEV, UL, VDE, etc. Polyamide has excellent electrical, mechanical, and chemical properties, even at high operating temperatures. Brief peak temperatures up to approximately 200°C are permitted as a result of heat aging stabilization. Depending on the type (PA 4.6, 6.6, 6.10, etc.), its melting point is in the region of 215°C to 295°C. Polyamide absorbs moisture from its surroundings, on average 2.8%. However, this moisture is not crystallization water in the plastic itself, but chemically bonded H2O groups in the molecular structure. This makes the plastic flexible and resistant to breakage, even at
temperatures as low as -40°C. As per UL 94, PA has a flammability rating of V2 to V0.
| NA
---|---|---
TPE general information| Main Characteristics:
Excellent flexural fatigue resistance Good electrical properties
Good tear & abrasion resistance
Resistance to Low & High Temperatures from -50°C to +140°C High impact strength
Colourability Recyclable
Excellent resistance to chemicals & weathering
| NA
Gasket| Top shell – bottom shell| Is part of the soft part| NA
Mechanical strenght| Droptest| at +20°C| A drop from 2 meters and this 5 times
on each side.| ALOXY
at +80°C
at – 45°C
Impact test| at +20°C| Resistant to 2 joule| ALOXY
at +80°C
at – 40°C| Only resistant up to -20°C. The housing will be adjusted for the
next production. We will have to| ALOXY
| | | do the tests again to see if we can lower the housing.|
---|---|---|---|---
Ingress Protection| IP65| Water jets. Water projected by a nozzle (6.3 mm)
against enclosure from any direction shall have no harmful effects. Test
duration: 1 minute per square meter for at least 3 minutes Water volume: 12.5
litres per minute Pressure: 30 kPa at distance of 3
m.
| ALOXY
IP68| 5m for 60 minutes| ALOXY
IP69| Powerful high temperature water jets. Protected against close-range high
pressure, high temperature spray downs. Specimens rotate slowly on a
turntable, from 4 specific angles. Test duration: Fixture: 30 sec. in each of
4 angles (2 min. total) Water volume: 14–16 litres per minute Pressure: 8–10
MPa (80–100 bar) at distance of
0.10–0.15 m Water temperature: 80 °C
| DEKRA 10/12/2019 Number 2235413.01-AOC
Torque| For gasket compression IP69| 0,45 Nm (0.33 ft lb)| NA
UV resistance| Chamber temperature 35-45°C Black standard temperature: 65°C
Intensity 0,5W/m² (340nm) Radiation dose 2,900Mj/m²
Rain cycle 102:18 Test duration:
After 0, 800, 1,600 and 3,200 hours exposed to UV (carousel) / weathering, the colour of the material is measured and expressed in the following scheme: Lab*:
L* (Brightness): 0 = black, 100 = white
a* (Colour): + = increased red, – = increased blue/green
b* (Colour): + = increased yellow, – = increased blue/purple
As the unexposed material is yellow, the value b and L are high. Tests show that weathering lowers b*, which is a typical reaction of the material under UV light (material tends to become yellowish with reduced “shining”), however, this effect is only minimal as the Aloxy material is already yellow. The material came from a bright colour to a more fade tone on the Greyscale of 2.5.
After testing there is no oil bleed out, no stickiness and no blooming after 3,200 hours of aging. As expected, there appear slight surface cracks, however the material stays intact with minimal impact on the shore.
| Tested by supplier according to DIN EN ISO 4892-2
---|---|---
Battery
(replaceable)
| | | | | Reference
T36851CCC| Lithium Metal battery with
supercap
| | 3,6V – 8500mAh| Custom made
E36850CCC| Lithium Metal battery without
supercap
| | 3,6V – 8500mAh| Custom made
E36851CCC| Lithium Metal battery with
supercap
| | 3,6V – 8500mAh| Custom made
Authonomy| DASH7| 5 to 8 years| ALOXY_MVP_001_Battery consumption
LoRaWAN| SF7| 5 to 6 years
| | SF9| 4 to 5 years|
---|---|---|---|---
SF12| 1 to 3 years
Optimal battery temperature
range
| -20°C to +50°C| ALOXY
PCB| | | | | Reference
Sensors| Accelerometer| ±2g/±4g/±8g/±16g acceleration scales| ALOXY
Gyroscoop| full-scale angular rate range of
±125/±250/±500/±1000/±2000 DPS
Magnetometer| dynamic range of ±50 gauss
Atmospheric pressure| 300hPa – 1250hPa
Ambient temperature|
NFC| ISO/IEC 15693 (AFI, Application Family Identifier)
LED’s| Green| 2X
Red| 2X
Wireless communication| | | | Reference
Communication protocol| DASH7 Appliance protocol v1.2| D7A Specification
Version
1.2
LoRaWAN class A, EU and USA| NA
Wireless Signal| 868MHz – 915MHz Maximum 10 dBm| NA
Wireless Classifications| Class A digital device, complies with part 15 of the
FCC Rules
Contains FCC ID: LW2RM2510
Contains IC: 2731A-RM2510
| NA
| GFSK| D7A Specification Version
1.2
LoRa| NA
Encription| AES-128 authentication and encryption|
Output power| Max 10dBm| ALOXY
| DASH7| 500m| ALOXY
Communication range| LoRaWAN| SF7| 500m| SF and distance to the gateways has a
profond inpact on the
battery life.
|
---|---|---|---|---|---
SF9| 1 km
SF12| <2 km
Frequency| DASH7 – EU| 863-870MHz| NA
LoRaWAN – EU| 867-870 MHz| NA
DASH7 – USA| 902-928MHz| NA
LoRaWAN – USA| 902-928MHz| NA
Payload| DASH7| max 251 bytes| NA
LoRaWAN| max 243 bytes depending on SF| NA
Latency| Dash7| max 1 sec| NA
LoRaWAN| up to 4 min| NA
EMC| Compliance| Europe| LDN: PCC-EMC-5002
LDN: PCC-RAD-4918
| | |
Rated condition| Reference
Ambient conditions| For use indoors and outdoors.| NA
Ambient temperature| In hazardous areas, observe the maximum permissible
ambient temperature corresponding to the temperature
class.
| NA
Permissible ambient temperature for operation| Permissible ambient temperature
for operation -40
to +70 °C (-40 … +112 °F)
| NA
Relative humidity| 0 … 100%| NA
IEC 61010 Compliance| Meets Pollution Degree 3| NA
Altitude Rating| Up to 2000 meters (6562 feet)| NA
Operating Temperature Limits| Battery Power: -40°C ≤ Ta ≤ +70°C (-40 to
158°F)| NA
Vibration
resistance
| Harmonic oscillations (sine) according to EN
60068-2-6/10.2008
| 3.5 mm (0.14″), 2 … 27 Hz, 3 cycles/axle
98.1 m/s² (321.84 ft/s²), 27 … 300 Hz, 3 cycles/axle
| Pending for evaluation
| Bumping (half-sine) according to EN 60068-2-
27/02.2010
| 150 m/s² (492 ft/s²), 6 ms, 1000 shocks/axle| Pending for evaluation
---|---|---|---
Noise (digitally controlled) according to EN 60068-2-64/04.2009| 10 … 200 Hz;
1 (m/s²)²/Hz (3.28 (ft/s²)²/Hz)
200 … 500 Hz; 0.3 (m/s²)²/Hz (0.98 (ft/s²)²/Hz)
4 hours/axle
| Pending for evaluation
Recommended range of continuous
operation of the entire manual valve:
| ≤ 30 m/s² (98.4 ft/s²) without resonance peak| Pending for evaluation
Documentation
Available
languages
| EN| | | |
| | | |
Safety instructions
Please read the user manual carefully.
It is an integral part of the described equipment and must be available at all
times.
Trademarks
All names identified by ® are registered trademarks of ALOXY NV. The remaining
trademarks in this publication may be trademarks whose use by third parties
for their own purposes could violate the rights of the owner. Disclaimer of
Liability We have reviewed the contents of this publication to ensure
consistency with the hardware and software described. Since variance cannot be
precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary
corrections are included in subsequent editions.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>