Aranet4 Home Indoor Air Quality Monitor User Manual

June 5, 2024
Aranet

Aranet4 Home Indoor Air Quality Monitor

Aranet4 Home Indoor Air Quality Monitor FIG 1

About the Aranet4 monitor

Aranet4 monitor is an innovative wireless device for effortless monitoring of indoor air quality – CO², relative humidity, temperature and atmospheric pressure*. The device is suitable for monitoring the CO² level at home, in school, office, or any other indoor environment. Measurement data is displayed on a power-efficient e-ink screen with a long battery life. Additionally, the device provides visual and optional buzzer notifications when the CO² concentration becomes unhealthy. CO² concentration levels of 1400 ppm (parts per million) and up are unhealthy and can cause drowsiness and decrease cognitive function by 50 %. A high concentration of CO² is an indicator of insufficient ventilation, which can increase the risk of infection with airborne diseases.Aranet4 Home Indoor Air Quality Monitor FIG 2

Aranet4 uses the nondispersive infrared (NDIR) sensor to measure the CO² concentration. The CO² gas in the chamber absorbs infrared light; this absorption is measured by the sensor. The
less light passes through, the higher the CO² concentration. CO² absorbs only a specific wavelength of light, therefore an optical filter is used. Aranet4
Home Indoor Air Quality Monitor FIG 3

Download the Aranet4 app and connect via Bluetooth with up to six devices. The app allows you to configure the Aranet4 device and access the data monitored by the device. Read a detailed description of all the possibilities that the app offers in the chapter “How to pair Aranet4 to my smart device using the Aranet4 app” on page 5. Additionally, up to 100 Aranet4 PRO devices can be connected to the Aranet PRO base station. Refer to the chapter “Using Aranet4 device with the Aranet PRO base station” on page 6. There are two Aranet4 models – Aranet4 HOME and Aranet4 PRO. You can find out more about how they differ in this informative leaflet. Measurement and data transmission** intervals are 1,2,5, or 10 minutes.
The default measurement interval is set to 5 minutes.

  • Atmospheric pressure data measurements are available only on the Aranet4 app.
    More information is in the chapter “How to pair the Aranet4 to my smart device using the Aranet4 app” on page 5.

  • For Aranet4 PRO paired to Aranet PRO base station.

The Aranet4 sensor screen explained

Aranet4 Home Indoor Air Quality
Monitor FIG 15

  1. The temperature of the air in Celsius or Fahrenheit. To change the temperature units, refer to the chapter
    “Switch positions explained” on page 4.

  2. Relative humidity of the air (RH %).

  3. CO² concentration level in ppm (parts per million).

  4. Buzzer status.
    The speaker symbol is visible when the buzzer is enabled. The buzzer’s settings can be adjusted using the Aranet4 app.

  5. CO² threshold level indication
    Green represents a good CO² level (below 1000 ppm) Yellow represents the average CO² level (1000 to 1400 ppm)
    Red represents an unhealthy CO² level (above 1400 ppm*)

  6. CO² calibration mode indication. Symbol is displayed when calibration is set to automatic. No letter is displayed when calibration is set to manual mode.

  7. For Aranet4 PRO only: Monitor identification number comprising five hexadecimal symbols of the Aranet4 PRO device (wirelessly connecting Aranet PRO base station & Aranet Cloud).

  8. Battery level.

  9. Adjustable CO² thresholds that can be set using the Aranet4 app.
    These are default thresholds that can be reconfigured using the Aranet4 app.

Aranet4 screen indications

  1. The inverted screen alerts when CO² concentration has reached the red threshold level.
  2. Do not remove batteries during a firmware upgrade.
  3. The batteries are empty. Replace them. Aranet4 Home Indoor Air Quality Monitor FIG 8
  4. The calibration progress.Aranet4 Home Indoor Air Quality Monitor FIG 9
  5. Six-digit pin code displayed for wirelessly connecting the device with your smartphone to the Aranet4 app via Bluetooth.
  6. Temperature below zero can damage the sensor. The recommended operating temperature of the sensor is 0 °C to 50 °C (32 °F to 122 °F).

CO² calibration

The Aranet4 monitor is calibrated at the factory. However, the user can carry out CO² calibration manually when needed. The general recommendation is to calibrate Aranet4 once a year, but more often if it is used in dusty environments. During the manual calibration, the Aranet4 device must be exposed to fresh outdoor air. Keep a distance of at least one meter from the device during the calibration process – no humans, animals, or plants should be closer to the device during calibration. You can calibrate your Aranet4 manually with or without the app. To manually calibrate Aranet4 with the Aranet4 app, pair your device with your smartphone (refer to the chapter “How to pair Aranet4 to my smart device using the Aranet4 app” on page 5), open Settings, and choose CO² calibration.
You can also calibrate the Aranet4 monitor manually without the app. To perform the manual
CO² calibration, flip the switch from MANUAL to AUTO and then back to MANUAL (flip the switch quickly, with less than one second between each movement). Once started, the
calibration progress will be displayed on the screen of the device. In case of a calibration failure message, make sure that the device is still in a fresh air environment and repeat the process from the beginning. To learn more about the switch positions, see the next chapter “Switch positions explained” on page 4. If the automatic calibration mode is used, the Aranet4 device needs to be exposed to fresh air at around 420 ppm (for instance, outdoors) for at least 8 hours each month.

Switch positions explained

The Aranet4 monitor has four small configuration switches that allow the user to adjust the settings.
To access the configuration switches, open the cover of the battery compartment on the back of the device. With the batteries remaining inside, adjust the switch position (up or down) using the pin tool supplied with the Aranet4 device. You can adjust the switches with the batteries removed as well, but note that, if you remove the batteries, it will erase the measurement history from Aranet4 memory. To avoid this, update the data in the Aranet4 app before removing the batteries. The new settings will start working once the batteries are back in. The positions of the configuration switches have the following meaning:Aranet4 Home Indoor Air Quality Monitor FIG 12

Switch tool (PIN) can be found in Aranet4 Quick Start Guide english version.

Aranet4 Home Indoor Air Quality Monitor FIG 13

How to pair Aranet4 to my smart device using the Aranet4 app

Download the Aranet4 app and connect your smartphone to the Aranet4 device via Bluetooth* to:

  • Access real-time measurement data.
  • Store up to 14-day measurement history and export it as a CSV file.
  • Track atmospheric pressure data.
  • Adjust CO² thresholds and set the buzzer. Change sensor measurement interval.
  • Access all nearby Aranet4 devices.
  • Carry out the CO² calibration of the device.
  • Activate firmware updates for the Aranet4 devices.
  • Enable Aranet4 connection to Homey smart home system.
  • Display Aranet4 measurements on larger TV screens.

To connect your Aranet4 to your smart device, make sure Bluetooth connectivity is enabled on your mobile device and your Aranet4 monitor, and follow these steps:

  • Launch the Aranet4 app.
  • Add Aranet4 to the app by pressing “+ PAIR NEW DEVICE” button.
  • Select the necessary Aranet4 from the devices list and press “+ PAIR”.
  • Accept the pairing procedure.
  • Enter the 6-digit pin code that is shown on the display of your Aranet4 device.

We advise you to check the app for Aranet4 newest firmware versions regularly and use the offered upgrades.Aranet4 Home Indoor Air Quality Monitor FIG
14

Find out more about the Aranet4 app in forum.aranet.com/all-about-aranet4

  1. Access to the device’s location should be allowed because of the general requirement for Bluetooth apps to work correctly on Android OS.

Using Aranet4 PRO monitor with the
Aranet PRO base station
The Aranet PRO base station collects and stores data from all types of Aranet sensors, including Aranet4 PRO. Up to 100 sensors can be connected to one base station. The Aranet PRO base station has an internal memory to store the measurement data for up to 10 years. Find out more about the Aranet PRO base station at aranet.com and follow the Aranet PRO User Manual for Europe or North America on how to pair Aranet sensors to the Aranet PRO base station.

Returns and warranty

  • Aranet4 protection class: IP 20.
  • Aranet4 is not impact-resistant.
  • Do not use Aranet4 in high humidity environments (greater than 85 %).
  • Do not leave Aranet4 in direct sunlight.

In case of a return or a warranty claim, please fill out the RMA form on the Aranet web page aranet.com/rma. For Terms and Conditions refer to aranet4.com/terms-conditions.
If you have purchased your device on Amazon, please follow Amazon’s Returns Policy.

Frequently asked q uestions (FAQ)
If you can’t find the answer that you are looking for in this manual, please take a look at the Aranet Forum at forum.aranet.com/all-about-aranet4. Otherwise, send us a message to support@aranet.com.

Additional links
More information about Aranet4 HOME can be found at aranet.com/product/aranet4-sensor
For additional documentation regarding Aranet4 PRO see aranet.com/product/aranet4-pro-sensor

For more information about Aranet products, please visit aranet.com, contact your Aranet representative or write to info@aranet.com. Product specifications are subject to change without prior notice. © 2022 SAF Tehnika, JSC. All rights reserved.

FCC compliance statement

This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used following the instructions, may interfere with radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment interferes with radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to avoid the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

“This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.”
The information presented in this guide is the property of SAF Tehnika, JSC. No part of this document may be reproduced or transmitted without proper permission from SAF Tehnika, JSC.
The specifications or information in this document are subject to change without notice due to continuing introduction of design improvements. If there is any conflict between this document and compliance statements, the latter will supersede this document. SAF Tehnika, JSC has no liability for typing errors in this document or damages of any kind that result from the use of this document. To get up-to-date information about accessories and their availability, please contact a sales representative.

Industry Canada Regulatory Statement
This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions:

(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Aranet User Manuals

Related Manuals