EFFI-FLEX-LG-CGX Flexible and Ultra High-Power Logistics Bar Light
User Manual
GENERAL PRODUCT INFORMATION
Thank you for purchasing an Effilux’s product. To ensure proper use of the product, please read this User manual before use and keep it for your future reference. Any improper use voids the warranty. This product is an LED light used for machine vision and industrial inspection. Do not use the product for other applications, and be sure to follow the instructions below.
Datasheets and drawings in PDF and/or CAD available upon request, please
contact Effilux.
The label(s) on the product always indicate(s) the reference, the power
consumption and the serial number of the product. Be sure to check the content
before using the product and handle the label(s) with care. The date of
manufacturing is included in the serial number of the product: XXXXXXYYMM-ZZZ
with YY corresponding to the year and MM to the month. If the label is missing
or damaged and the content cannot be checked, please contact Effilux.
GENERAL WARNINGS AND PRECAUTIONS OF USE
Maintenance
The product must be switch off during any maintenance operation. To remove
marks on the lens or on the window: Use alcohol-free lens cleaning fluid on a
cleaning tissue. Few drops will suffice. Please clean gently. Always apply the
fluid to a tissue rather than the lens itself. To clean optical components:
Please wear gloves and use compressed air if there is dust.
Usage and storage environment
Except if a specific IP rating is given for your product (refer to the «Dust and Water resistance (IP rating) » section), please install the product to locations with following conditions (Incorrect installation location may causes product failure) :
User security
Incorrect use of the product may result in fire, electric shock, or other
serious damages. Please ensure to follow below conditions. If an abnormal
condition occurs (fuming, heat, noises, etc.), stop using the product
immediately and turn the power off.
PART NUMBER KEY
Standard version
Available options: References
Please refer to the datasheet for the specifications of a product with option(s).
AVAILABLE ACCESSORIES
ELECTRICAL INSTALLATION
SmartSense Function
The EFFI-Flex-LG CGX version has 2 operating modes and 2 M12 connectors.
Depending on the wiring, the light can be used either with direct connection
to the camera or with an additional external power supply for longer strobes.
The EFFI-Flex-LG CGX detects automatically the operating mode, Thanks to this SmartSense function, the user can easily shift from standard mode to power mode (longer strobes) just by connecting the additional power supply:
- Mode 1 (Direct connection): Connect only the Main connector to the camera.
- Mode 2 (Longer strobe pulse): Connect also the Auxiliary connector to an external power supply.
How to connect the EFFI-Flex-LG?
The EFFI-Flex-LG CGX requires 24V DC input power. Note the trigger pin needs to be connected to a PNP trigger signal.
Initialization phase
When EFFI-Flex-LG CGX is supplied, the product first enters in a few seconds initialization phase. This initialization is a sequence of very short strobes of increasing intensity. Please wait until the end of this initialization to use the product (max 5 seconds).
MegaStrobe feature
Power consumption
OPTICAL FLEXIBILITY
Be careful to always open the product from the side without the connector.
How to change the optical configuration?
The EFFI-Flex-LG offers flexible lens positioning to control the beam angle and different type of diffusers to adapt the uniformity. The user can easily change the diffuser and the lens position.
How to install a polarizer accessory?
By using polarizers, on the Effilux light and on the camera, it is possible to
eliminate glare from your workpiece making it easier to acquire a suitable
image for the application. The user can insert directly the polarizer inside
the EFFI-Flex-LG, under the window.
Important note:
– The polarization is optimal with a LD window, the use of SD or OP window can
depolarize the light. Important note:
– The polarization is optimal with a LD window, the use of SD or OP window can
depolarize the light.
MECHANICAL CONSIDERATION
How to use the bracket kit?
There is two mounting holes on the bracket to optimize the orientation of the
bar depending on the lens position:
- Pos 1 for the first lens position P1 (45°)
- Pos 2 for the second lens position P2 (25°)
REGULATIONS COMPLIANCY
The FCC mark indicates that it complies with part 15 of the FCC Rules (US FCC Class A (47 CFR § 15.19)). Operation is subject to the following 2 conditions:
(1) This device may not cause harmful interference,
(2) this device must accept any interference received, including interference
that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
CAN ICES-003(A) / NMB-003(A)
This Class A digital apparatus complies with Canadian ICES-003.
ENVIRONMENTAL REGULATIONS
EU RoHS Directive
The EU RoHS Directive is short for the «Restriction Of use of certain
Hazardous Substances in electrical and electronic equipment». The EU RoHS
Directive (2011/65/EU) restricts the use of specifics hazardous substances for
the new electronic equipment marketed in the EU. The Directive (EU) 2015/863
amending 2011/65/EU was published in 2015 to restrict the use of specific
hazardous substances, including six conventional substances, lead (<0.1%),
mercury (<0.1%), cadmium (<0.01%), hexavalent chromium (<0.1%), polybrominated
biphenyl (PBB) (0.1%) and polybrominated diphenyl ether (PBDE) (<0.1%), as
well as four substances (phthalate compounds), bis(2-Ethylhexyl) phthalate
(DEHP) (<0.1%), benzyl butyl phthalate (BBP) (<0.1%), dibutyl phthalate (DBP)
(<0.1%), diisobutyl phthalate (DIBP) (<0.1%). Our products do not contain the
above certain hazardaous substances in excess of the maximum permitted
concentration. However, this does not apply if the product falls under the
exemption.
China RoHS
China RoHS Directive is formally known as «Management Methods for Restricting
Hazardous Substances Used in Electric and Electronic Products», which was
implemented on July 1rst, 2016 in China. Same as EU RoHS Directive
(2011/65/EU), this regulation restricts the usage of same six substances. This
regulation requires electronic information products which are manufactured or
imported, and sold in China, to clearly disclose contents of the 6 restricted
substances listed below.
WARRANTY
EFFILUX products come with a warranty of 2 years (one year for radiant quantity), starting from EFFILUX shipping date. Any improper use voids the warranty.
Exceptions: UV products (<420nm): 1-year warranty / Chillers: 1-year warranty / Polarizers are excluded from warranty.
For more information, please refer to the warranty information available on Effilux’s website.
CONTACT INFORMATION
Please refer to the specific documentation (datasheet, user manual and drawing) for complementary information. Contents of this document are based on information available as of Mar-2022 and may be changed without prior notice.
EFFILUX
1, Rue de Terre Neuve
Mini Parc du Verger – Bâtiment E 91940 Les Ulis – FRANCE
Tel: +33 9 72 38 17 80 Fax: +33 9 72 11 21 69 Mail: sales@effilux.fr